• Title/Summary/Keyword: Left ventricular filling pressure

Search Result 5, Processing Time 0.022 seconds

Hemodynamic Influences of Positive End-Expiratory Pressure Ventilation in Patients with Pulmonary Insufficiency (호기말 양압호흡이 혈류역학 및 심기능에 미치는 영향)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.79-85
    • /
    • 1985
  • The effect of graded increments in positive end-expiratory pressure [PEEP] on hemodynamics required to ventilate 8 critically ill patients is reported. Acute respiratory insufficiency was a cause of death in only one patient of drug inoxication among the 8 patients studied. The cardiac output was not changed significantly after the increment of PEEP to the level of 20 cm H2O. The heart rate was increased significantly from 15 cm H2O PEEP [P<0.01] as compared to 0 cm H2O PEEP; and the stroke volume was decreased significantly from 15 cm H2O PEEP [P<0.05]. The blood pressure was not affected at any level of PEEP, but the pulmonary artery pressure was elevated significantly at 10 cm H2O PEEP [P<0.01]. The right ventricular transmural filling pressure was not affected at the level of 10 cm H2O PEEP, but from 15 cm H2O PEEP it was increased significantly. With the increment of PEEP, the left ventricular stroke work index was decreased slightly; and at 20 cm H2O PEEP, it was decreased significantly. The right ventricular stroke work index was increased only at 10 cm H2O PEEP. The systemic vascular resistance was decreased significantly from 15 cm H2O PEEP [P<0.01].

  • PDF

Impact of Hemodialysis on Left Ventricular Performance: A Doppler Echocardiographic Study (혈액투석 유지요법 환자에서 투석 전후의 좌심실 Doppler 심초음파를 이용한 기능지표의 변화)

  • Kang, Dong-Oh;Lee, Du-Ha;Kim, Hyun-Seo;Kim, Hyun-Su;Kim, Sung-Rok;Park, Jong-Seon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.309-317
    • /
    • 1999
  • Background: Left ventricular diastolic filling is an important determinant for maintenance of cardiac output during hemodialysis. Few investigators have studied the influence of hemodialysis on diastolic function. To evaluate the change of left ventricular systolic and diastolic function. we performed M-mode and Doppler echocardiographic studies before and after hemodialysis. Methods: The study population consisted of 30 patients(15 patients were male, mean age $45{\pm}10$ years) with CRF on maintenance hemodialysis. They have normal left ventricular systolic function(Fractional shortening>30%) and no evidence of valvular heart disease or regional wall motion abnormalities. The ejection fraction (EF) was measured using M-mode echocardiography and Doppler indices such as peak E velocity, peak A velocity, isovolumetric relaxation time(IVRT), deceleration time(DT). and left ventricular ejection time(LVET) obtained from Doppler echocardiography. The index of myocardial performance (IMP) was calculated from each of the Doppler velocity indices. Results: The weight reduction after hemodialysis was $2.1{\pm}1.0kg$(p<0.0001), After hemodialysis, there was some decrease in blood pressure(p<0.05), but no significant change in heart rate, EF and fractional shortening, mean VCF, peak A velocity, and DT. And significant reduction in peak E velocity, E/A ratio(p<0.0001. p<0.001), and significant increase in IVRT and IMP(p<0.05, p<0.0001) were noted. Conclusion: In conclusion, preload reduction is the main mechanism that accounts for changes in Doppler diastolic indices after hemodialysis. And an increased IMP suggests that diastolic function may be aggravated after hemodialysis, and that implies impaired left ventricular filling and disturbed left ventricular compliance.

  • PDF

Truncus Arteriosus, Type IV -one case report- (동맥간증 제 IV형 -1예 보고-)

  • 이종태
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.243-249
    • /
    • 1980
  • Truncus ateriosus is one of the cyanotic congenital heart disease. The incidence is relatively uncommon, as 0.4% of totoal congenital heart disease. Embryologically the defect is due to a lack of partitioning of the embryonic truncus and conus during the first few weeks of fetal life. The ventricular septal defect is invariable present. A single arterial vessel arises from the heart and supplies blood to the aorta, the lung, and the coronary arteries. In 1949, collett and Edwards classified this defect according to anatomic variation to four major types, such as type I, II, III, and IV. Type IV is defined that pulmonary arteries are absent, and the pulmonary arterial supply arises from the descending thoracic aorta. This patients often have a continuous murmur head particularly well in the interscapular area. No effective surgical treatment is available. We have experienced one case of truncus arteriosus, type IV of Collett and Edwards in the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. This patient was 10 year-old girl. The chief complaints were cyanosis and dyspnea on exertion since birth. She was admitted at this hospital on April 16, 1980. The continous machinery murmur was heard loudest at the interscapular area. The chest X-ray films revealed cardiomegaly with an increase in pulmonaryvascular markings. The pulmonary secotr was significantly concave. No filling of pulmonary arteries noticed by the right ventriculogram. There was possible biventricular hypertrophy in EKG. The echocardiogram showed that the demension of the aortic root was larger than normal and minimal increase of the left ventricular internal dimension. The cardiac catheterization data was obtained by use of the great saphenus vein approach. The systolic pressure of the right ventricular outflow tract was 80 mmHg and was similar to that of the aorta. The oxygen saturation data revealed the evidence of the left to right shunt at the level of ventricular septum. The patient was operated and the diagnosis was confirmed as trucus arteriosus, type IV. No effective surgical interventins were performed.

  • PDF

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

Impacts of Diastolic Function on Clinical Outcomes in Young Patients with Acute Myocardial Infarction (젊은 급성 심근경색증 환자에서 좌심실 이완 기능 및 충만압이 관상동맥중재술 후 임상 경과에 미치는 영향)

  • Cho, Eun Young;Jeong, Myung Ho;Yoon, Hyun Ju;Kim, Yong Cheol;Sohn, Seok-Joon;Kim, Min Chul;Sim, Doo Sun;Hong, Young Joon;Kim, Ju Han;Ahn, Youngkeun;Cho, Jae Young;Kim, Kye Hun;Park, Jong Chun
    • The Korean Journal of Medicine
    • /
    • v.93 no.6
    • /
    • pp.538-547
    • /
    • 2018
  • Background/Aims: The impact of left ventricular (LV) diastolic function and filling pressure on clinical outcomes in young patients with acute myocardial infarction (AMI) has been poorly studied. Therefore, the aim of this study was to investigate the impact of LV diastolic function and LV filling pressure on major adverse cardiac events (MACEs) in young patients with AMI. Methods: A total of 200 young patients (males < 45 year, females < 55 year) with AMI were divided into two groups according to the diastolic function; normal (n = 46, $39.5{\pm}5.3$ years) versus abnormal (n = 154, $43.5{\pm}5.1$ years). Results: Despite regional wall motion abnormalities, normal LV diastolic function was not uncommon in young AMI patients (23.0%). During the 40 months of clinical follow-up, MACEs developed in 26 patients (13.0%); 14 re-percutaneous coronary intervention (7.0%), 8 recurrent MI (4.0%), and 4 deaths (2.0%). MACEs did not differ between the normal and abnormal diastolic function group (13.6% vs. 10.9%, p = 0.810), but MACEs were significantly higher in the high LV filling pressure group than the normal LV filling pressure group (36.8% vs. 10.5%, p < 0.001). On multivariate analysis, high LV filling pressure was an independent predictor of MACEs (hazard ratio 3.022, 95% confidence interval 1.200-7.612, p = 0.019). Conclusions: This study suggested that measurement of the LV filling pressure (E/e' ratio) would be useful in the risk stratification of young patients with AMI. However, it would be necessary to monitor this category of patient more carefully.