• Title/Summary/Keyword: Left heart ventricle

Search Result 297, Processing Time 0.023 seconds

The effect of Aconiti tuber butanol fraction on the rabbit heart microsomal $Na^+-K^+$-activated ATPase activity (부자 Butanol Fraction이 가토 심장근 Microsomal $Na^+-K^+$-activated ATPase 활성도에 미치는 영향)

  • Shin, S.G.;Lim, J.K.;Park, C.W.;Kim, M.S.
    • The Korean Journal of Pharmacology
    • /
    • v.12 no.1
    • /
    • pp.7-14
    • /
    • 1976
  • Aconiti tuber butanol fraction shows positive inotropic effect on the isolated atrium of rabbit heart. To investigate the mechanism, the effect on microsomal ATPase activity of rabbit heart is observed. The microsomal fraction which contains the $Na^+$- and $K^+$-activated ATPase in the presence of $Mg^{++}$ is isolated from the left ventricle of rabbit heart. The microsomal ATPase activity is maximally stimulated at $Na^+$ and $K^+$ concentration of 100 mM and 10 mM respectively. Microsomal $Na^+-K^+$-activated ATPase is inhibited by ouabain and Aconiti tuber butanol fraction. Ouabain and Aconiti tuber butanol fraction depress $Na^+$-stimulation on microsomal ATPase activity, and the inhibitory effects are not completely reversed at $Na^+$ concentration of 300 mM. Also, $K^+$-stimulation on microsomal ATPase activity is inhibited by ouabin and Aconiti tuber butanol fraction and the inhibitions are not compeletely reversed at $K^+$ concentration of 30 mM. It is, therefore, suggested that the inhibitory effect of Aconiti tuber butanol fraction on the microsomal ATPase activity may contribute to leading to the positive inotropic effect.

  • PDF

Development and Animal Tests of Pneumatic Ventricular Assist Device (공압식 심실보조장치의 개발 및 동물실험)

  • 박영환;김상현
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.247-252
    • /
    • 1997
  • Ten acute and chronic in vivo studies were utilized to develop a pneumatic ventricular assist device (VAD) as a bridge to heart transplantation or a circulatory assist device for patients with end-stage heart disease or poor myocardial funct on after cardiac surgery. Two sizes of blood pump of 70cc for adult patients and 34cc for pediatric patients were implanted in the animals. Ventricle of the blood pump was made from the polyurethaae to enhance antithrombogenecity. The VAD was implanted between the left atrium and the descending aorta. Average flow rate was 2.38 L/min for adult and 0.41 L/min for pediatric VAD at the rate of 60 bum. The duration of support ranged from 1 to 26 hours. The most frequent complication was bleeding. Main causes of death were heart failure and respiratory failure. The device function was good for short term use. Studies to date suggest that, with further refinement, a reliable long term VAD that will have clinical application can be developed.

  • PDF

A Case of Supravalvular Pulmonic Stenosis in a Maltese Dog (말티즈견에서 발생한 판막상형 폐동맥판 협착증 증례)

  • Kim, Seong-Jun;Kang, Min-Hee;Kim, Su-Chan;Choi, Young-Chul;Kim, Seung-Gon;Lee, Chang-Min;Jung, Da-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.325-328
    • /
    • 2014
  • A 8-month-old female Maltese dog was presented with a history of heart murmur. In physical examination, grade 4/6 systolic murmur heard at the left heart base. Electrocardiography showed sinus arrhythmia, right axis deviation, deep S wave and splintered QRS complex. Thoracic radiography revealed enlarged right side heart and bulging of the main pulmonary artery. Echocardiography showed mild hypertrophy of right ventricle, a supravalvular stenosis, marked post-stenotic dilation of the main pulmonary artery and a moderately increased pulmonary arterial velocity through the stenotic area (4.4 m/s, pressure gradient of 78.7 mmHg). The dog was diagnosed with supravalvular pulmonic stenosis based on the diagnostic imaging findings. Medical management using ${\beta}1$-blocker and ACE inhibitor was started in this dog and this is first case report described diagnostic characteristic features of supravalvular pulmonic stenosis in korea.

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

Development of Cardiac Digital Subtraction Angiographic System for Diagnosis of Cardiac Diseases (심장병 진단을 위한 실시간 디지탈 감산 조영 영상기법의 개발)

  • Min, Byoung-Goo;Lee, Tae-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.132-139
    • /
    • 1989
  • We have designed a real-time Cardiac digital substraction angiography system (C-DSA) and tested the system for the diagnosis of Cardiac patients. The system was developed by interfacing a radiographic angiography system to a computerized motional image analysis system. This new cardiac DSA can perform the real time processing of averaging and subtraction of the 32 image frames to measure the volume changes of the left ventricle after elimination of motional artrifacts, caused by the heart contraction of beats per minute in average. Each frame has a resolution of 512 x 512 pixels and 256 gray levels. Two image data with maximal and minimal volume were moved to the interfaced IBM PC computer system by high speed computer link line for computation of the heart's contraction parameters. First, the boundary of the left ventricule was detected using a dynamic programming of the gray levels, and its volume was computered to determine the parameters, such as the maximal volume of end-diastolic volume (EDV), the minimal volume of end systolic volume (ESV), and ejection fraction (EF).

  • PDF

Relationship between atrial pressures and the interventricular pressure in the moving actuator type total artificial heart (심실간 공간 압력을 이용한 이동작동기형 완전이식 인공심장에서의 좌, 우심방압 추정)

  • Jo, Y.H.;Choi, W.W.;Park, S.K.;Choi, J.S.;Lee, J.J.;Om, K.S.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.88-90
    • /
    • 1996
  • The right and left atrial pressures are important parameters in automatic control of a total artificial heart (TAH) within normal physiological ranges. Our TAH is composed of a moving actuator, right and left ventricles and the interventricular space enclosed by a semi-rigid housing. During operation of the TAH, the jnterventpicular space's volume is changed dynamically by the difference between the ejection volume of one ventricle and the inflow volume of the other. Therefore, the changes in pressure of the interventricular space is related to both atrial pressures. We measured the interventricular pressure (IVP) waveform using a pressure sensor and attempted to indirectly estimate the changes of atrial pressures. This method has an advantage that the sensor does not contact the blood directly. Furthermore, the IVP waveforms have its zero baseline in each pump cycle, thus the pressure measurements are free from the transducer drift problems by measuring the peak pressure from these baseline values. From the In vitro experiments, we found that the IVP waveform contained several useful parameters such as negative peak, dP/dT on the initial break, the area enclosed by the profile in each stroke, which are associated with atrial pressures and the filling conditions of the ventricles. The measured atrial pressures were linearly related to the negative peak of the interventricular pressure.

  • PDF

Evaluation by Contrast-Enhanced MR Imaging of the Lateral Border Zone in Reperfused Myocardial Infarction in a Cat Model

  • Ae Kyung Jeong;Sang Il Choi;Dong Hun Kim;Sung Bin Park;Seoung Soo Lee;Seong Hoon Choi;Tae-Hwan Lim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 2001
  • Objective: To identify and evaluate the lateral border zone by comparing the size and distribution of the abnormal signal area demonstrated by MR imaging with the infarct area revealed by pathological examination in a reperfused myocardial infarction cat model. Materials and Methods: In eight cats, the left anterior descending coronary artery was occluded for 90 minutes, and this was followed by 90 minutes of reperfusion. ECG-triggered breath-hold turbo spin-echo T2-weighted MR images were initially obtained along the short axis of the heart before the administration of contrast media. After the injection of Gadomer-17 and Gadophrin-2, contrast-enhanced T1-weighted MR images were obtained for three hours. The size of the abnormal signal area seen on each image was compared with that of the infarct area after TTC staining. To assess ultrastructural changes in the myocardium at the infarct area, lateral border zone and normal myocardium, electron microscopic examination was performed. Results: The high signal area seen on T2-weighted images and the enhanced area seen on Gadomer-17-enhanced T1WI were larger than the enhanced area on Gadophrin-2-enhanced T1WI and the infarct area revealed by TTC staining; the difference was expressed as a percentage of the size of the total left ventricle mass (T2= 39.2 %; Gadomer-17 =37.25 % vs Gadophrin-2 = 29.6 %; TTC staining = 28.2 %; p < 0.05). The ultrastructural changes seen at the lateral border zone were compatible with reversible myocardial damage. Conclusion: In a reperfused myocardial infarction cat model, the presence and size of the lateral border zone can be determined by means of Gadomer-17- and Gadophrin-2-enhanced MR imaging.

  • PDF

Protocol Optimization of Coronary CT Angiography (심혈관 CT 조영술의 프로토콜 최적화)

  • Lee, Hae-Kag;Yoo, Heung-Joon;Lee, Sun-Yeob;Goo, Eun-Hoe;Seok, Jong-Min;Han, Man-Seok;Lee, Kwang-Sung;Cho, Jae-Hwan;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2011
  • This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.

Recovery Trajectory in Tachycardia Induced Heart Failure Model (빈맥을 이용한 심부전 모델에서 회복궤도)

  • 오중환;박승일;원준호;김은기;이종국
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.422-427
    • /
    • 1999
  • Background: Tachycardia induced heart failure model would be the model of choice for the dilated cardiomyopathy. This more closely resembles the clinical syndrome and does not require major surgical trauma, myocardial ischemia and pharmacological or toxic depression of cardiac function. When heart failure is progressive, application of new surgical procedures to the faling heart is highly risky. It has been shown that recovery trajectory from heart failure is a new method in decreasing animal mortality. The purpose is to establish the control datas for recovery trajectory in the canine heart failure model. Material and Method: 21 mongrel dogs were studied at 4 stages(baseline, at the heart failure, 4 and 8 weeks after recovery). Heart failure was induced during 4 weeks of continuous rapid pacing using a pacemaker. Eight weeks of trajectory of recovery period was allowed. Indices of left ventricular function and dimension were measured every 2 weeks and the hemodynamics were measured by use of Swan-Ganz catheterization and thermodilution method every 4 weeks. Values were expressed as mean${\pm}$standard deviation. Result: 4(20%) dogs died due to heart failure. Left ventricular end-diastolic volume at the 4 stages were 40.8${\pm}$7.4, 82.1${\pm}$21.1, 59.9${\pm}$7.7 and 46.5${\pm}$6.5ml. Left ventricular end-systolic volume showed the same trend. Ejection fractions were 50.6${\pm}$4.1, 17.5${\pm}$5.8, 36.3${\pm}$7.3, and 41.5${\pm}$2.4%. Blood pressure and heart rate showed no significant changes. Pressures of central vein, right ventricle, pulmonary artery, and pulmonary capillary wedge showed significant increase during the heart failure period, normalizing at the end of recovery period. Stroke volumes were 21.5${\pm}$8.2, 12.3${\pm}$3.5, 17.9${\pm}$4.6, and 15.5${\pm}$3.4ml. Blood norepinephrine level was 133.3${\pm}$60.0pg/dL at the baseline and 479.4${\pm}$327.3pg/dL at the heart failure stage(p=0.008). Conclusion: Development of tachycardia induced heart failure model is of high priority due to ready availability and reasonable amenability to measurements. Recovery trajectory after cessation of tachycardia showed reduction of cardiac dilatation and heart function. Application of new surgical procedures during the recovery period could decrease animal mortality.

  • PDF

A Case Report of Left Ventricular Remodeling Surgery on End-Stage Dilated Cardiomyopatty (말기 심부전 환자의 좌심실 개조수술 1례보고)

  • 임창영;기주이
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.613-616
    • /
    • 1997
  • We present a case of 58-year-old (tamale with dilated cardiomyopathy(DCMP) in whom we performed left ventricular(LV) remodeling surgery(Batista operation) to reduce the left ventricle diameter and improve left ventricular unction. The patient was admitted September 1996 with heart failure NYHA class IV. There was severe orthopnea and peripheral edema. 2-D echocardiography(Echo) showed DCMP with the ejection fraction(EF) I5%, LV end diastolic dimension(LVEDD) 80mm, mitral regurgitation(MR) grade IV, tricuspid regurgitation ('m) grade ll. Preoperative cardiac output(CO) was 1.5/L/min and cardiac index(Cl) was 1.0 L/min/m2. We proceeded with LV remodeling surgery by resection a part of LV lateral wall between both papillary muscle, from the mitral annulus to the LV apex. Size of resected LV wall was 90 $\times$ 100 $\times$ 15 mm. At the mean time, mitral valve and tricuspid valve were repaired. Postoperative 2-D Echo showed the EF 37%, LVEDD 50 mna, trivial MR, no TR. CO was 3.SL/min and Cl was 2.3 L/min/m2. Her fuctional NYHA class was 1.

  • PDF