• Title/Summary/Keyword: Lee Tae Joon

Search Result 1,726, Processing Time 0.032 seconds

Oral administration of H. syriacus L. flower ameliorates photoaging and dryness in UVB-irradiated skin (무궁화 꽃 추출물 경구투여에 의한 피부 광노화 및 건조증 개선에 관한 효과)

  • Yang, Jung-Eun;Seo, Seul A;Kang, Min Cheol;Yoon, Da Hye;Im, Tae Joon;Hwang, Eunson;Won, Kyung Hwa;Lee, Teak Hwan;Kim, Sun Yeou
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.4
    • /
    • pp.399-407
    • /
    • 2021
  • Wrinkle formation and dryness are the most well-known symptoms of skin aging. This study investigated skin anti-aging and moisturizing effects of Mugunghwa (Hibiscus syriacus L.), the national flower of Korea. The effect of H. syriacus L. flower extract was examined in skin cells originating from humans in vitro and in hairless mice exposed to UVB in vivo. The in vivo study results showed that skin hydration-related factors such as involucrin, filaggrin, HAS1, HYAL1, and matrix metalloproteinase-I (a primary skin photoaging factor) were regulated by H. syriacus L. Additionally, epidermal thickness and collagen disruption, which resulted in wrinkle formation and skin dryness, were ameliorated by oral administration of H. syriacus L. These results indicate that H. syriacus L. flowers can play important roles in preventing aging and promoting skin moisturizing.

Factors and Elements for Cross-border Entrepreneurial Migration: An Exploratory Study of Global Startups in South Korea (델파이 기법과 AHP를 이용한 글로벌 창업이주 요인 탐색 연구: 국내 인바운드 사례를 중심으로)

  • Choi, Hwa-joon;Kim, Tae-yong;Lee, Jungwoo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.4
    • /
    • pp.31-43
    • /
    • 2022
  • Startups are recognized as the vitality of the economy, and countries are competing to attract competitive overseas entrepreneurs and startups to their own startup ecosystem. In this global trend, entrepreneurs cross the border without hesitation, expecting abundant available resources and a startup friendly environment. Despite the increasing frequency of start-up migration between countries, studies related to this are very rare. Therefore, this study has chosen the cross-border migration of startups between countries as a research topic, and those who have been involved in the cross-border entrepreneurial migration to South Korea as a research sample. This study consists of two stages. The first research stage hires a Delphi method to collect expert opinions and find major factors related to the global startup migration. Drawing on the prior literature on the regional startup ecosystem at the national level, this stage is to conduct expert interviews in order to discover underlying factors and subfactors important for global migration of startups. The second stage measures the importance of the factors and subfactors using the AHP model. The priorities of factors and factors were identified hiring the overseas entrepreneurs who moved to Korea as the AHP survey samples. The results of this study suggest some interesting implications. First, a group of entrepreneurs with nomadic tendencies was found in the trend of global migration of entrepreneurs. They had already started their own businesses with the same business ideas in multiple countries before settling down in Korea. Second, important unique factors and subfactors in the context of global start-up migration were identified. A good example is the government's support package, including start-up visas. Third, it was possible to know the priority of the factors and subfactors that influence the global migration of startups This study is meaningful in that it preemptively conducted exploratory research focusing on a relatively new phenomenon of global startup migration, which recently catches attention in the global startup ecosystem. At the same time, it has a limitation in that it is difficult to generalize the meanings found in this study because the research was conducted based on the case of South Korea

A Study on The Effect of Psychological State occurred by the Organizational Change and Public Service Motivation on the JobAttitude: A comparison before and after the Implementation of Relocation of Electric Power Public Corporation to Local Areas (조직변화에 따른 심리상태와 공공봉사동기가 직무태도에 미치는 영향 조사연구: 전력공기업의 지방 이전 실시 전후의 비교)

  • Lee, Joon Tae
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.3
    • /
    • pp.147-163
    • /
    • 2022
  • The relocation policy of public Institutions throughout provincial areas that implemented for the purpose of "balanced national development" finished in 2019 with the last relocation of the Korea Institute of Science & Technology Evaluation and Planning, which moved to Chungbuk Innovation City. Electric power public corporations also completed relocation program over eight regions across the nation. This study was conducted empirically to identify the structural relationship between the public service motivation and job attitude. In this, the relationship of organizational change, particularly occurred by the regional relocation, with the psychological state of these organization members (experienced direct changes and got substantial impacts in various aspects such as psychological, economic and living environment, etc.,) was studied. This study aims to seek early organizational stabilization ideas for electric power public corporations after relocation, and to present some implications that can contribute to the secondary relocation of public institutions to local areas. This study shows the statistically significant relationship between the psychological state occurred by relocation and organizational commitment. The result shows that the higher the expectation levels, the higher the degree of organizational commitment, while anxious psychological state has no relation with that. Additionally, expectation level has no significant functional relation with turnover intention. Followings are the major conclusions revealed in this study; The stronger the anxious psychological state, the higher the turnover inducement goes up. The higher the expectation levels, the higher the public service motivation grows, and the higher the anxiety psychological state, the public service motivation lowers. The organizational commitment grows according to the public service motivation proportionally, but the turnover inducement intention is weak. The moderating effect of public service motivation between the expectation of organizational change and turnover intention was not significant, but it was analyzed that the moderating effect of public service motivation formed a significant relationship with other anxiety psychology. The expectation levels of employees of electric power public corporations has grown up after moving to provincial areas. Relationship between the expectation mind and the turnover inducement has decreased after local relocation.

Characteristics of Particulate Carbon in the Ambient Air in the Korean Peninsula (한반도 권역별 대기 중 입자상 탄소 특성 연구)

  • Lee, Yeong-jae;Park, Mi-kyung;Jung, Sun-a;Kim, Sun-jung;Jo, Mi-ra;Song, In-ho;Lyu, Young-sook;Lim, Yong-jae;Kim, Jung-hoon;Jung, Hae-jin;Lee, Sang-uk;Choi, Won-Jun;Ahn, Joon-young;Lee, Min-hee;Kang, Hyun-jung;Park, Seung-myeong;Seo, Seok-jun;Jung, Dong-hee;Hyun, Joo-kyeong;Park, Jong-sung;Hwang, Tae-kyung;Hong, You-deog;Hong, Ji-hyung;Shin, Hye-jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.4
    • /
    • pp.330-344
    • /
    • 2015
  • Semi-continuous measurements of $PM_{2.5}$ mass, organic and elemental carbon were made for the period of January to October 2014, at six national air monitoring stations in Korea. OC and EC concentrations showed a clear seasonal variation with the highest in winter (January) and the lowest in summer (August). In winter, the high carbonaceous concentrations were likely influenced by increased fuel combustion from residential heating. OC and EC concentrations varied by monitoring stations with 5.9 and $1.7{\mu}g/m^3$ in Joongbu area, 4.2 and $1.2{\mu}g/m^3$ in Honam area, 4.0 and $1.3{\mu}g/m^3$ in Yeongnam area, 3.7 and $1.6{\mu}g/m^3$ in Seoul Metropolitan area, 3.0 and $0.8{\mu}g/m^3$ in Jeju Island, 2.9 and $0.7{\mu}g/m^3$ in Baengnyeong Island respectively. The concentrations of OC and EC comprised 9.6~ 15.5% and 2.4~ 4.7% of $PM_{2.5}$. Urban Joongbu area located adjacent to the intersection of several main roads showed the highest carbon concentration among six national air monitoring station. On the other hand, background Baengnyeong Island showed the lowest carbon concentration and the highest OC/EC ratio (4.5). During the haze episode, OC and EC were enhanced with increase in $PM_{2.5}$ about 1.3~ 3 and 1.3~ 4.0 times respectively. The concentrations of OC, EC in the Asian dust case are about 1~ 2.4 times greater than in the nondust case. The origins of air mass pathways arriving at Seoul, using the backward trajectory analysis, can be mostly classified into 6 groups (Sector I Northern Korea including the sea of Okhotsk, Sector II Northern China including Mongolia, Sector III Southern China, Sector IV South Pacific area, Sector V Japan, Sector VI Southern Korea area). When an air mass originating from northern China and Mongolia, the OC concentrations were the most elevated, with a higher OC/EC ratio (2.4~ 3.3), and accounting for 17% of $PM_{2.5}$ mass on average.

A Multicenter, Randomized, Open, Comparative Study for the Efficacy and Safety of Oral Moxifloxacin 400 mg Once a Day and Clarithromycin 500 mg Twice Daily in Korean Patients with Acute Exacerbations of Chronic Bronchitis (한국인의 만성 기관지염의 급성 악화 환자를 대상으로 한 Moxifloxacin 400mg 1 일 1회 요법과 Clarithromycin 500mg 1일 2회 요법의 치료효과 및 안전성 비교)

  • Kim, Seung-Joon;Kim, Seok-Chan;Lee, Sook-Young;Yoon, Hyeong-Kyu;Kim, Tae-Yon;Kim, Young-Kyoon;Song, Jeong-Sup;Park, Sung-Hak;Kim, Ho-Joong;Chung, Man-Pyo;Suh, Gee-Young;Kwon, O-Jung;Lee, Shin -Hyung;Kang, Kyung-Ho;Lee, Eh-Hyung;Hwang, Sung-Chul;Han, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.740-751
    • /
    • 2000
  • Background : Moxifloxacin is a newly developed drug which is more potent and safe compared to previous fluoroquinolones. This drug effectively eradicates organisms such as beta-lactamase-producing or other resistant bacteria. Moxifloxacin is known to be effective in treating respiratory infections such as Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catarrhalis, Chlamydia pneumoniaeme, Legionella spp. and Mycoplasma pneumoniae. Methods : In a multicenter, randomized, open, comparative study, the efficacy and safety of oral moxifloxacin taken 400 mg once a day and clarithromycin taken 500 mg twice daily for 7 days were compared for the treatment of Korean patients with acute exacerbations of chronic bronchitis. Results : A total of 170 patients were enrolled, and they were divided into two groups: 87 in the moxifloxacin group and 83 in the clarithromycin group. Of those enrolled, 76 (35 for bacteriologic efficacy) in the moxifloxacin group and 77 (31 for bacteriologic efficacy) in the clarithromycin group were included in the efficacy analysis. All were included in the safety analysis. Clinical success was noted in 70 (92.1%) of 76 moxifloxacin-treated patients and 71 (92.2%) of 77 clarithromycin-treated patients. Bacteriologic success rate seemed to be higher in moxifloxacin group (73.5%) than in clarithromycin group (54.8%), but statistically insignificant (p=0.098). Drug susceptibility among organisms initially isolated was higher in moxifloxacin group on Streptococcus pneumoniae, Pseudomonas aeruginosa, Klebsiella pneumoniae (p<0.001). Adverse events were reported by 12.8% of 86 patients receiving moxifloxacin and 21.7% of 83 patients receiving clarithromycin. Headache (4.7% vs 4.8%, moxifloxacin group vs clarithromycin group, respectively) and indigestion (2.3% vs 6.0%, moxifloxacin group vs clarithromycin group, respectively) were the most frequent side effects in the two groups. Conclusion : This study demonstrated that for the treatment of acute exacerbations of chronic bronchitis a 7-day course of moxifloxacin 400 mg od was clinically equivalent and microbiologically superior to clarithromycin 500 mg bid.

  • PDF

A Comparison of Tiotropium 18㎍, Once Daily and Ipratropium 40㎍, 4 Times Daily in a Double-Blind, Double-Dummy, Efficacy and Safety Study in Adults with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 Tiotropium 1일 1회, 1회 18㎍ 요법과 Ipratropium 1일 4회, 1회 40㎍ 요법의 치료효과 및 안전성 비교)

  • Kim, Seung Joon;Kim, Myung Sook;Lee, Sang Haak;Kim, Young Kyoon;Moon, Hwa Sik;Park, Sung Hak;Lee, Sang Yeub;In, Kwang Ho;Lee, Chang Youl;Kim, Young Sam;Kim, Hyung Jung;Ahn, Chul Min;Kim, Sung Kyu;Kim, Kyung Rok;Cha, Seung Ick;Jung, Tae Hoon;Kim, Mi Ok;Park, Sung Soo;Choi, Cheon Woong;Yoo, Jee Hong;Kang, Hong Mo;Koh, Won Jung;Ham, Hyoung Suk;Kang, Eun Hae;Kwon, O Jung;Lee, Yang Deok;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun;Shin, Won Hyuk;Kwon, Sung Yeon;Kim, Woo Jin;Yoo, Chul Gyu;Kim, Young Whan;Shim, Young Soo;Han, Sung Koo;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Mi Hye;Lee, Won Yeon;Yong, Suk Joong;Shin, Kye Chul;Choi, Byoung Whui;Oh, Yeon Mok;Lim, Chae Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Jung, Sung Soo;Kim, Ju Ock;Ko, Young Chun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.498-506
    • /
    • 2005
  • Background : This study compared the bronchodilator efficacy and safety of tiotropium inhalation capsules ($18{\mu}g$ once daily) with a ipratropium metered dose inhaler (2 puffs of $20{\mu}g$ q.i.d.) in patients with chronic obstructive pulmonary disease (COPD). Method : After the initial screening assessment and a two-week run-in period, patients received either tiotropium $18{\mu}g$ once daily or ipratropium $40{\mu}g$ four times daily over a period of 4 weeks in a double blind, double dummy, parallel group study. The outcome measures were the lung function, the daily records of the peak expiratory flow rate (PEFR), the patients' questionnaire, and the use of concomitant salbutamol. The forced expiratory volume in one second ($FEV_1$) and the forced vital capacity (FVC) were measured 5 minutes before inhalation, and 0.5, 1, 2 and 3 hours after inhaling the study drug on days 0, 14 and 28. Result : In 16 centers, 134 patients with a mean (SD) age of 66 (7) years and a predicted $FEV_1$ of 42 (12)% were analyzed. The trough $FEV_1$ response was significantly higher in the tiotropium group than in the ipratropium group after a four-week treatment period. The weekly mean morning PEFR of the tiotropium group was consistently higher than that of the ipratropium group during the 4-week treatment period with differences ranging from 12.52 to 13.88 l/min, which were statistically significant. Tiotropium was well tolerated by the COPD patients during the 4-week treatment period and had a similar safety profile to ipratropium. Conclusion : This study shows that tiotropium administrated once daily has a superior bronchodilator effect with a similar safety profile in treating COPD patients compared with ipratropium, inhaled four times daily.

Comparison of the Operative Results of Performing Endoscopic Robot Assisted Minimally Invasive Surgery Versus Conventional Cardiac Surgery (수술용 내시경 로봇(AESOP)을 이용한 최소 침습적 개심술과 동 기간에 시행된 전통적인 개심술의 결과에 대한 비교)

  • Lee, Young-Ook;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.598-604
    • /
    • 2008
  • Background: The improvements in endoscopic equipment and surgical robots has encouraged the performance of minimally invasive cardiac operations. Yet only a few Korean studies have compared this procedure with the sternotomy approach. Material and Method: Between December 2005 and July 2007, 48 patients (group A) underwent minimally invasive cardiac surgery with AESOP through a small right thoracotomy. During the same period, 50 patients (group B) underwent conventional surgery. We compared the operative time, the operative results, the post-operative pain and the recovery of both groups. Result: There was no hospital mortality and there were no significant differences in the incidence of operative complications between the two groups. The operative $(292.7{\pm}61.7\;and\;264.0{\pm}47.9min$, respectively; p=0.01) and CPB times ($128.4{\pm}37.6\;and\;101.7{\pm}32.5min$, respectively; <0.01) were longer for group A, whereas there was no difference between the aortic cross clamp times ($82.1{\pm}35.0\;and\;87.8{\pm}113.5min$, respectively; p=0.74) and ventilator times ($18.0{\pm}18.4\;and\;19.7{\pm}9.7$ hr, respectively; p=0.57) between the groups. The stay on the ICU $(53.2{\pm}40.2\;and\;72.8{\pm}42.1hr$, respectively; p=0.02) and the hospitalization time ($9.7{\pm}7.2\;and\;14.8{\pm}11.9days$, respectively; p=0.01) were shorter for group A. The Patients in group B had more transfusions, but the difference was not significant. For the overall operative intervals, which ranged from one to four weeks, the pair score was significantly lower for the patients of group A than for the patients of group B. In terms of the postoperative activities, which were measured by the Duke Activity Scale questionnaire, the functional status score was clearly higher for group A compared to group B. The analysis showed no difference in the severity of either post-repair of mitral ($0.7{\pm}1.0\;and\;0.9{\pm}0.9$, respectively; p=0.60) and tricuspid regurgitation ($1.0{\pm}0.9\;and\;1.1{\pm}1.0$, respectively; p=0.89). In both groups, there were no valve related complications, except for one patient with paravalvular leakage in each group. Conclusion: These results show that compared with the median sternotomy patients, the patients who underwent minimally invasive surgery enjoyed significant postoperative advantages such as less pain, a more rapid return to full activity, improved cosmetics and a reduced hospital stay. The minimally invasive surgery can be done with similar clinical safety compared to the conventional surgery that's done through a median sternotomy.

Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province (가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태)

  • Ahn, Jong-Joon;Lee, Ki-Man;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.624-632
    • /
    • 2000
  • Background : Home ventilation can decrease hospital-acquired infection, increase physical activity, improve nutritional status, enhance quality of life, and reduce medical costs. The number of patient using home ventilators has been increasing, particularly in Europe and United States. Although the number of patients with home ventilation has been increasing in Korea, the current status of these patients is not well known. This study was undertaken to obtain basic information upon these patients in addition to evaluating any problems related to patients' home care in our country. Methods : A register of 92 patients with home ventilators in Seoul and Kyunggi Province were obtained from commercial ventilator supply companies. The patients were contacted by phone and 29 of them accepted our visit. Information concerning education about home care before discharge, equipment cost, and problems related to home care were documented. The mode and preset variables of the home ventilator were checked; tidal volume (TV), peak airway pressure, and oxygen saturation were measured. Results : There were 26 males (90%) and their mean age was 48.0 (${\pm}20.1$) years. The underlying diseases were : 21 neuromuscular disorders, 2 spinal cord injuries, 6 chronic lung diseases. Among the caregivers, spouses (n=14) predominated. Education for home care before discharge was performed primarily by intensive care unit nurses and the education for ventilator management by commercial companies. Twenty-five of the 29 patients had tracheostomies. Volume targeted type (VTT ; n=20, 69%) was more frequently used than the pressure targeted type (PTT). Twenty-three of the 29 patients purchased a ventilator privately, which cost 7,450,000 (${\pm}$3,290,000) won for a PTT, and 14,280.000 (${\pm}$3,130,000) won for a VTT. Total cost for the equipment was 11,430,000 (${\pm}$634,000) won. The average cost required for home care per month was 1,120,000 (${\pm}$1,360, 000) won. Conclusion : The commonest underlying disease of the patients was neuromuscular disease. The VTT ventilator was primarily used with tracheostomy. Patients and their families considered the financial difficulties associated with purchasing and maintaining equipment for home care an urgent problem. Some patients were aided by a visiting nurse, however most patients were neglected and left without professional medical supervision.

  • PDF

The Findings of Pulmonary Function Test in Patients with Inhalation Injury (흡입화상 환자에서의 폐기능검사 소견)

  • Kim, Jong Yeop;Kim, Cheol Hong;Shin, Hyun Won;Chae, Young Je;Choi, Chul Young;Shin, Tae Rim;Park, Yong Bum;Lee, Jae Young;Bahn, Joon-Woo;Park, Sang Myeon;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.653-662
    • /
    • 2006
  • Background: The changes in the pulmonary function observed in burn patients with an inhalation injury are probably the result of a combination of airway inflammation, chest wall and muscular abnormalities, and scar formation. In addition, it appears that prolonged ventilatory support and an episode of pneumonia contribute to the findings. This study investigated the changes in the pulmonary function in patients with inhalation injury at the early and late post-burn periods. Methods: From August 1, 2002, to August 30, 2005, surviving burn patients who had an inhalation injury were enrolled prospectively. An inhalation injury was identified by bronchoscopy within 48hours after admission. Spirometry was performed at the early phase during admission and the recovery phase after discharge, and the changes in the pulmonary function were compared. Results: 37 patients (M=28, F=9) with a total burn surface area (% TBSA), ranging from 0 to 18%, were included. The initial $PaO_2/$FiO_2$ratio and COHb were $286.4{\pm}129.6mmHg$ and $7.8{\pm}6.6%$. Nine cases (24.3%) underwent endotracheal intubation and 3 cases (8.1%) underwent mechanical ventilation. The initial X-ray findings revealed abnormalities in, 18 cases (48.6%) with 15 (83.3%) of these being completely resolved. However, 3 (16.7%) of these had residual sequela. The initial pulmonary function test, showed an obstructive pattern in 9 (24.3%) with 4 (44.4%) of these showing a positive bronchodilator response, A restrictive pattern was also observed in 9 (24.3%) patients. A lower DLco was observed in only 4 (17.4%) patients of which 23 had undergone DLco. In the follow-up study, an obstructive and restrictive pattern was observed in only one (2.7%) case each. All the decreased DLco returned to mormal. Conclusions: Most surviving burn patients with an inhalation injury but with a small burn size showed initial derangements in the pulmonary function test that was restored to a normal lung function during the follow up period.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.