• Title/Summary/Keyword: Lee Sam

Search Result 4,879, Processing Time 0.042 seconds

Effect of the a floor plan of lobby floor for the Stack Effect in a High-rise Building (고층건물에서 로비층의 평면형태가 연돌효과에 미치는 영향)

  • Lee, June-Ho;Lim, Hyun-Woo;Seo, Jung-Min;Lee, Joong-Hoon;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.293-299
    • /
    • 2009
  • Many kinds of problems by stack effect occur in the high-rise buildings that have the simple plan on the first floor designed only by an external wall and an E/V shaft wall. Therefore, some buildings in the foreign countries has made the additional inside walls between lobby and E/V hall as a countermeasure on stack effect. An additional wall in the lobby is very useful countermeasure on stack problems because lobby is a main airflow path in the building. Decreasing effect on stack problems by an additional wall of lobby is reported in this study. An ordinary office building that has a simple lobby plan is simulated and measured in this study. The results show that characteristics on stack effect are changed by methods of applying additional walls and that alternations of countermeasures which building conditions like the kinds of problems and the problem's velocity etc. are considered are very important.

  • PDF

A study on application of an E/V shaft cooling system to reduce the stack effect in high-rise building (연돌효과 저감을 위한 E/V샤프트 냉각장치의 적용에 대한 연구)

  • Lim, Hyun-Woo;Lee, June-Ho;Seo, Jung-Min;Lee, Jung-Hun;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.284-292
    • /
    • 2009
  • The stack-effect in high-rise buildings in winter causes many problems such as difficulties in opening or closing doors, infiltration, energy loss, noise and fire protection. Stack effect is influenced by temperature difference between the interior and exterior of building and the height of building. As an attenuation method for stack effect, the architectural methods are generally used. However, as though architectural methods were fully adopted, the problems are reported as ever in tall building. In this study, a new method to reduce stack effect will be suggested. As an active control method against the stack effect, E/V shaft natural cooling method is suggested. In this paper, the concept of E/V shaft natural cooling system and its reduction performance of stack effect by simulation and field measurement will be reported.

  • PDF

Case of Solitary Pancreatic Metastasis from Small Cell Lung Cancer

  • Park, Chul;Kim, Tae Hyeon;Yun, Ki Jung;Choi, Soon Ho;Lee, Sam Youn;Lee, Mi Kyung;Ryu, Dae Woong;Yang, Sei Hoon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.6
    • /
    • pp.980-982
    • /
    • 2012
  • Metastasis to the pancreas from extra-pancreatic primary cancers are rare; they commonly present as a manifestation of widespread disease and rarely as an isolated mass of the pancreas. Examinations showed a pancreatic tumor infiltrating the pancreas tail portion and an endoscopic ultrasound guided percutaneous biopsy proved that the lesion was metastatic from the lung carcinoma. Most metastatic cases of the pancreas tend to be discovered in patients with widely disseminated malignant disease. In addition, patients with pancreatic metastasis are often asymptomatic, the metastatic lesions are found incidentally, and are misdiagnosed as primary pancreatic tumors. This report that patient undergoing chemotherapy for a small cell lung cancer, who 1 year and 3 months later, accidentally diagnosed of solitary pancreas metastasis and confirmed histology by needle biopsy using endoscopic ultrasound.

Comparison on serological reaction between complement fixation test and enzyme-linked immunosorbent assay for detection of antibodies against Sendai virus, mouse hepatitis virus and Mycoplasma pulmonis in mice and rats (마우스 및 랫트의 Sendai virus, mouse hepatitis Virus, Mycoplama pulmonis 감염(感染)에 대한 보체결합반응(補體結合反應)과 효소표식면역흡착측정법(酵素標識免疫吸着測定法)과의 비교(比較))

  • Chung, Yoo-yeul;Lee, Hak-cheul;Lee, Eun;Yoo, Byung-sam
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.4
    • /
    • pp.517-523
    • /
    • 1989
  • This study was undertaken to establish reliable diagnostic-procedures for the microbiological monitoring of laboratory animals. Murine(mice and rats) antibodies against hemagglutinating virus of Japan(HVJ), mouse hepatitis virus(MHV) and Mycoplasma pulmonis(Mp) were detected sensitively and specifically in experimentally and naturally infected animals' sera by an indirect enzyme-linked immunosorbent assay(ELISA), using urease conjugated antimurine immunoglobulin. The sensitivity and specificity of the complement fixation test which has been apllied widely for serodiagnosis of HVJ, MHV and Mp infections were apparently lower than those of ELISA. From these results, the ELISA was found to be available for the serodiagnosis of HVJ, MHV and Mp infections in mice and rats.

  • PDF

Immunohistochemical electron microscopic studies on somatotropes and mammotropes in hypophysis of Korean native goat (한국재래산양 뇌하수체의 성장자극세포와 젖샘자극세포에 관한 전자현미경적 연구)

  • Lee, In-se;Lee, Heungshik S.;Won, Moo-ho;Seo, Jehoon;Song, Seung-hoon;Nam, Young-Sam;Kang, Tae-Cheon
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.488-496
    • /
    • 1998
  • Somatotropes, mammotropes and somatomammotropes of the Korean native goat hypophysis were studied by double immunoelectron microscopy using antisera to growth hormone(GH) and prolactin(PRL), and protein A-gold particles of different sizes. Mammotropes were round or oval in shape, and contained round and electron dense secretory granules. The size of secretory granules was variable from 460nm to 680nm in diameter. Somatotropes were elliptical or triangular in shape and the oval nucei were located eccentrically at the periphery of the cell. Secretory granules of the cell were oval in shape and clearly distinguished from round granules of mammotropes. The size of granules was 320~680nm in diameter, smaller than that of mammotropes. Somatomammotropes contained round or oval secretory granules. The granules had intermediate size between somatotropes and mammotropes. Some of granules contained both GH and PRL, while the others contained only one of them.

  • PDF

Water Quality Control System Development for Cooling Towers (냉각탑 수질관리를 위한 자동화 시스템 개발)

  • Lee, Ki-Keon;Song, Moo-Jun;Lee, Young-Jae;Sung, Sang-Kyung;Kang, Tae-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.

Modeling analysis of air-gap control system of a rotary small-scale model of a Linear Induction Motor for a railway transit (철도차량용 회전형 축소모델 LIM 시험기의 공극조절시스템 모델링 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo;Park, Hyun-June;Kwon, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1057-1058
    • /
    • 2008
  • 철도차량용 선형추진시스템에 있어서, 지상레일에 설치되는 선형유도전동기의 2차측의 리액션플레이트의 시공 공차에 의해서 발생되는 1차측과의 공극의 변화는 추진 시스템의 운행 시 승차감과 기기효율을 떨어뜨리는 결과를 초래하기 때문에 선형유도전동기의 균일 공극 운전은 추진 시스템의 효율을 증가시킬 수 있는 중요한 사항이다. 또한 경사구간에서의 선형유도전동기의 공극길이 조절을 통해서 선형유도 전동기의 용량 변경 없이 추력을 증가시키는 것이 가능하다. 따라서 본 논문에서는 선형유도전동기의 공극 길이를 제어할 수 있으며, 공극 길이제어를 통하여 추진 시스템의 성능 변화를 살펴볼 수 있는 축소 모델선형유도전동기 성능시험기의 공극조절 시스템의 동적 모델링 및 특성 해석을 통하여 시스템을 구성하는 파라미터들의 특성 변화 분석 및 시스템 구현 가능성에 대한 연구를 수행하였다.

  • PDF

A Case of Pancytopenia with Hyperthyroidism

  • Kim, Tae Hoon;Yoon, Ji Sung;Park, Byung Sam;Lee, Dong Won;Cho, Jae Ho;Moon, Jun Sung;Kim, Eui Hyun;Won, Kyu Chang;Lee, Hyoung Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.1
    • /
    • pp.47-50
    • /
    • 2013
  • There has been an increase in the number of reports of atypical manifestations of Graves' disease (GD), such as jaundice, anemia, thrombocytopenia and leukopenia. Pancytopenia also rarely occurs in GD. In this paper, a case of pancytopenia with GD that was successfully treated with an anti-thyroid drug is reported. In this case, a 69-year-old woman showed pancytopenia with a normal peripheral blood smear, bone marrow aspiration smear and bone marrow biopsy. Her thyroid function test and thyroid scintigraphy confirmed her hyperthyroid status. Her laboratory abnormality and clinical condition improved after she was treated with an anti-thyroid drug. This is a rare case of pancytopenia associated with GD.

A study on mechanical characterization of nano-thick films fabricated by transfer assembly technique (이송조립기술로 제조된 나노 박막의 기계적인 특성 평가에 관한 연구)

  • Choi, Hyun-Ju;Kim, Jae-Hyun;Lee, Sang-Joo;Lee, Hak-Joo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.30-34
    • /
    • 2008
  • The transfer assembly (or transfer printing) technique is a promising method for fabricating multi-scale structures on various substrates including semiconductors and polymers, and has been applied to fabrication of flexible devices with superior performance to conventional organic flexible devices. The mechanical behaviors of the structures fabricated by the transfer assembly is a very important information for design and reliability evaluation purpose, but the measurement of the behaviors is difficult since their critical-dimensions are very tiny. In this study, Au films with nano-scale thickness were fabricated on a silicon substrate and their mechanical properties were measured using micro-tensile test. The Au films on the silicon substrate were then transferred to a PDMS substrate using the transfer assembly technique. Self-assembled monolayer (SAM) with a thiol group was used to enhance the transfer of Au films, and the mechanical behaviors were characterized using wrinkle-based test. The test results from micro-tensile and wrinkle-based test are compared to each other, and their implication to the transfer assembly technique is discussed.

  • PDF

Benign neurilemmoma in the infratemporal fossa involving maxillary sinus and pterygopalatine fossa

  • Choi Jin-Woo;Reo Min-Suk;An Chang-Ryeon;Lee Jin-Koo;Yi Won-Jin;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.215-218
    • /
    • 2004
  • Neurilemmoma is a benign tumor of the nerve sheath that arises on cranial and spinal nerve roots as well as along the course of peripheral nerves. A case of a neurilemmoma that arose in the left infratemporal fossa of a 29-year-old male was presented. Plain radiographs, enhanced computed tomography scan, and magnetic resonance imaging demonstrated a large, well-circumscribed, heterogeneously enhanced mass with extension into the pterygopalatine fossa. Displaced by the large mass, bowing-in of the posterior maxillary antral wall was noted and a provisional diagnosis of a benign soft tissue tumor was made. The mass was completely excised and a diagnosis of neurilemmoma was confirmed.

  • PDF