• Title/Summary/Keyword: Lee Ha-Bok

Search Result 446, Processing Time 0.036 seconds

The Design and Construction of Smart Power Grid Field Application System (Smart Power Grid 실증시스템 설계 및 구축)

  • Ha, Bok-Nam;Lee, Seong-Woo;Jang, Moon-Jong;NamGung, Won;Seo, In-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.720-721
    • /
    • 2011
  • 본 논문에서는 제주 스마트그리드실증단지에서 진행중인 스마트그리드 5개 프로젝트 중 송배전분야의 전력망을 통합 운영하는 Smart Power Grid(SPG) 실증시스템의 설계와 구축 현황에 대해서 기술한다. 스마트그리드 프로젝트는 SPG외에도 ST(Smart Transportation), SP(Smart Place), SR(Smart Renewable), SES(mart Electric Service)가 있는데, SPG는 SES 프로젝트에서 운영하는 통합관제센터(TOC)를 거쳐 ST, SR, SP 시스템들과 운전 정보를 서로 교환하여 사용한다.

  • PDF

Smart Power Grid demonstration state and plan of second stage (Smart Power Grid 실증시스템 구축 현황 및 2단계 확대 계획)

  • NamKoong, Won;Lee, Sung-Woo;Jang, Moon-Jong;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.728-729
    • /
    • 2011
  • Smart Power Grid (SPG) 분야 실증 플랜드 구축과제는 스마트그리드 플랫폼 기반에서 송전, 변전, 배전 분야의 전력기기와 운영 시스템을 통합해 전력망을 효율적, 지능적으로 운전할 수 있는지를 실증하는 프로젝트이다. 현재 스마트그리드 실증단지에는 송전계통의 무효전력관리시스템, 위성망을 이용한 전압위상관리시스템, 송전선로용 볼센서 등을 다루는 지능형 송전, IEC 61850 기반의 IED를 채용한 변전소 자동화, 전기품질 온라인 감시기능을 갖는 지능형 단말장치를 적용 및 변전소 SCADA 기능을 통합 구현하는 배전지능화가 설치되어 있다.

  • PDF

Integration of control center using intelligent distribution management system (배전지능화시스템을 활용한 제어센터 통합방안 연구)

  • Ha, Bok-Nam;Lee, Seong-Woo;Shin, Chang-Hoon;Park, Min-Ho;Park, So-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.318_320
    • /
    • 2009
  • SCADA시스템은 변전소 구내에 시설되어 있는 설비를 원격에서 감시제어하는 시스템이고, 배전자동화시스템(DAS)은 배전선로에시설되어 있는 각종 배전설비를 원격에서 감시제어하고 있는 시스템이다. 이 시스템들은 독립적인 시스템으로 개발되었고 각각 다른 제어 센터에서 운영이 되고 있다. 본 논문에서는 변전설비를 집중 감시제어하는 SCADA시스템과 배전설비를 감시제어하는 배전자동화시스템을 한 제어센터에서 통합 운영하기 위한 방안을 검토하였다. 개별 시스템의 특징과 기능, 시스템 구성방법 및 연계방안을 기술적으로 분석하여 제어센터의 통합 방안을 기술하였다.

  • PDF

A Using Study for Fault Locator Algorithm of Distribution System (배전계통 고장점 표정 알고리즘 적용 연구)

  • Lee, Sung-Woo;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.74_76
    • /
    • 2009
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

  • PDF

Characterization and Structural Dtercination of an Antifungal Compound Produced by Pseudomonas aeruginosa KGM-100 (Pseudomonas aeruginosa KGM-100이 생산하는 항생물질의 특성 및 구조)

  • Kim, Kyung-Seok;Hong, Su-Hyung;Lee, Eun-Ju;Park, Yong-Bok;Park, Yong-Tae;Ha, Ji-Hong
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.1
    • /
    • pp.98-103
    • /
    • 1995
  • During the screening of antifungal antibiotics from microbial metabolites, we selected Pseudomonas aeruginosa KGM-100 showing powerful antagonistic activity against various phytopathogenic fungi. Antibiotics KGM-100A and KGM-100B were purified from the culture broth of Pseudomonas aeruginosa KGM-100 by diaion HP-20 column chromatography, ethyl acetate extraction, silica gel column chromatography, preparative TLC and recrystallization. KGM-100A which was recrystallized in MeOH showed antimicrobial activities against a broad spectrum of fungi and bacteria. Physico-chemical properties of KGM-100A were determined and identified to be phenazine-l-carboxylic acid by UV, IR, $^{1}$H-NMR, $^{13}$C-NMR, mass spectrum, and elemental analyses.

  • PDF

An Improved Method of Faulted Section Identification Algorithm in Distribution Automation System (배전자동화시스템에서 단말장치의 고장표시 정보 생성 알고리즘 개선 방법)

  • Lim, Il-Hyung;Lim, Seong-Il;Lee, Seung-Jae;Kwon, Sung-Chul;Shin, Chang-Hoon;Ha, Bok-Nam;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.651-659
    • /
    • 2007
  • This paper proposes an improved fault indication algorithm in a distribution automation system. A conventional fault indication method, so called YES-NO algorithm, could generate wrong informations under certain conditions such as line to ground fault, large motor double circuit line. In order to prevent mal-operation of fault indicator, direction of fault current are used as well as magnitude. The feasibility of the proposed algorithm has been testified by computer simulation using Matlab power system toolbox.

Distributed Restoration System based on Multi-Agent for Improving Restoration in Distribution Automation System (배전자동화 시스템의 복구기능 향상을 위한 Multi-Agent 기반의 분산형 정전복구 시스템)

  • Lim, Seong-Il;Lim, Il-Hyung;Lee, Seung-Jae;Kwon, Sung-Chul;Ha, Bok-Nam;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.660-668
    • /
    • 2007
  • In order to improve the efficiency of service restoration function in the current Distribution Automation System (DAS), in this paper it is proposed a more advanced and efficient service restoration approach using Multi-Agent technique based on distributed networks. In the current DAS, communication networks or protocol structures are centralized with communications between the central station and FRTU through 1:1 connection. In order to maintain the current systems and enhance the proposed Multi-Agent based service restoration scheme, a device of communication and intelligence, named MASX, is newly developed to make a FRTU as an agent to cooperate each others. the proposed system applied in a demo system for an distribution automation system and shows 8 times reduction of restoration time in restoration of blackouts.

A Method for Optimal Location of Feeder Tie Switches for Improving Equal Load of Electric Power Equipment in Distribution Automation System (배전자동화 시스템에서 전력설비 부하균등화를 고려한 피더간 연계점 최적위치선정)

  • Lim, Il-Hyung;Lim, Seong-Il;Choi, Myeon-Song;Lee, Seung-Jae;Shin, Chang-Hoon;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.821-828
    • /
    • 2007
  • This paper proposes a new algorithm to find optimal location of open switches connecting feeders in distribuion system. In order to enhance power system reliability by minimizing outage area in case of fault, the load balance among the facilities such as transformers and feeders is considered to optimize. The combination of optimal position of normal open switches can be found by moving tie along the direct path connecting two feeders related to the open switch while the whole optimization problem is separated into many small problems. The proposed algorithm is shown by case study results that, it is simple and takes short calculation time to apply to the DAS (Distribution Automation System) in KEPCO (Korea Electric Power Cooperation).

The upgrade of coordination program for distribution automation system (배전자동화용 보호협조프로그램 개선)

  • Seol, Leel-Ho;Ha, Bok-Nam;Park, Shin-Yeol;Jung, Young-Beom;Lee, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.629-631
    • /
    • 2005
  • The DASPRO (Protection Coordination Program for DAS) is one of the application programs for Distribution Automation System (DAS) of the KEPCO. Application programs developed by KEPCO provide optimal operation in distribution network. The DASPRO includes diverse functions to operate network as construction of database using existing information. creation of diagram for protection coordination. calculation of fault current. evaluation network. power quality monitoring, etc. The DASPRO can examine validity of setting values for protective devices by comparing to T-C curves. Unless the protection coordination is correct, the most suitable setting value for protection devices are displayed on the screen. In this paper, I will introduce the contents of the DASPRO.

  • PDF

Development target of intelligent DAS with the function of distribution transformer monitoring (배전변압기 감시제어 기능이 통합된 지능형 배전자동화 시스템 개발 방향)

  • Ha, Bok-Nam;Seol, Lee-Ho;Park, Shin-Yeol;Jeong, Yeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.554-556
    • /
    • 2005
  • Distribution Automation System (DAS) will provide supervision and remote control of switches and reclosers such as pole pounted switches and pad-mounted switchgears on high voltage distribution line. Kepco had developed basic function such as remote monitoring, remote control, remote measuring and remote setting at first. As a next step, Kepco has been developed diverse application programs such as single line diagram drawing program, relay coordination program, feeder reconfiguration program, over load elimination program, bad data detection program, section load management program, fault processing program and so on. Kepco is examining to develop more powerful functions for special specification of foreign distribution automation system. This paper explains what is the target for overseas DAS market.

  • PDF