• Title/Summary/Keyword: Leaks

Search Result 431, Processing Time 0.029 seconds

A Study on Security Container to Prevent Data Leaks (정보 유출 방지를 위한 보안 컨테이너의 효과성 연구)

  • Lee, Jong-Shik;Lee, Kyeong-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1225-1241
    • /
    • 2014
  • Recently, Financial companies implement DLP(Data Leaks Prevention) security products and enforce internal controls to prevent customer information leaks. Accidental data leaks in financial business increase more and more because internal controls are insufficient. Security officials and IT operation staffs struggle to plan countermeasures to respond to all kinds of accidental data leaks. It is difficult to prevent data leaks and to control information flow in business without research applications that handle business and privacy information. Therefore this paper describes business and privacy information flow on applications and how to plan and deploy security container based OS-level and Hypervisor virtualization technology to enforce internal controls for applications. After building security container, it was verified to implement internal controls and to prevent customer information leaks. With security policies additional security functions was implemented in security container and With recycling security container costs and time of response to security vulnerabilities was reduced.

A Study on Industrial Technology Leakage and Effective Industrial Security Measures through analysis of domestic portal article data (국내 포털 기사자료 분석을 통한 산업기술유출 사례와 산업보안 강화 방안 연구)

  • Yang, Hyun Jung;Lee, Chang Moo
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.3-13
    • /
    • 2017
  • In the knowledge-information society, many domestic companies put lots of investment in technical development to possess core technologies and intellectual property. However, in the results of passive investment in security to protect their technologies compared to the active investment in technical development, the technology leaks from many companies and research institutes are rapidly increasing. Such increase of technology leaks not only causes damage to companies, but also has harmful effects on national economy directly and indirectly. Even though it has been perceived that a lot of industrial technology leak crimes are committed by former/current workers of small and medium-sized businesses, it is hard to find researches that mainly compare and analyze them. Therefore, this study aimed to understand the actual status of industrial technology leaks by analyzing cases of industrial technology leaks from 2014 to 2016 based on the type of victimized companies, corporate internal leakers' positions, matter of complicity, tools used for technology leaks, and motivation for technology leaks. Through the analysis in each type, the patterns and characteristics of industrial technology leaks were researched, and also the exploratory research on industrial security for the prevention of industrial technology leaks was conducted.

Role of Barium Swallow in Diagnosing Clinically Significant Anastomotic Leak following Esophagectomy

  • Roh, Simon;Iannettoni, Mark D.;Keech, John C.;Bashir, Mohammad;Gruber, Peter J.;Parekh, Kalpaj R.
    • Journal of Chest Surgery
    • /
    • v.49 no.2
    • /
    • pp.99-106
    • /
    • 2016
  • Background: Barium swallow is performed following esophagectomy to evaluate the anastomosis for detection of leaks and to assess the emptying of the gastric conduit. The aim of this study was to evaluate the reliability of the barium swallow study in diagnosing anastomotic leaks following esophagectomy. Methods: Patients who underwent esophagectomy from January 2000 to December 2013 at our institution were investigated. Barium swallow was routinely done between days 5-7 to detect a leak. These results were compared to clinically determined leaks (defined by neck wound infection requiring jejunal feeds and or parenteral nutrition) during the postoperative period. The sensitivity and specificity of barium swallow in diagnosing clinically significant anastomotic leaks was determined. Results: A total of 395 esophagectomies were performed (mean age, 62.2 years). The indications for the esophagectomy were as follows: malignancy (n=320), high-grade dysplasia (n=14), perforation (n=27), benign stricture (n=7), achalasia (n=16), and other (n=11). A variety of techniques were used including transhiatal (n=351), McKeown (n=35), and Ivor Lewis (n=9) esophagectomies. Operative mortality was 2.8% (n=11). Three hundred and sixty-eight patients (93%) underwent barium swallow study after esophagectomy. Clinically significant anastomotic leak was identified in 36 patients (9.8%). Barium swallow was able to detect only 13/36 clinically significant leaks. The sensitivity of the swallow in diagnosing a leak was 36% and specificity was 97%. The positive and negative predictive values of barium swallow study in detecting leaks were 59% and 93%, respectively. Conclusion: Barium swallow is an insensitive but specific test for detecting leaks at the cervical anastomotic site after esophagectomy.

Management of Cerebrospinal Fluid Leak after Traumatic Cervical Spinal Cord Injury (경추 손상 후 뇌척수액 유출에 대한 관리)

  • Lee, Soo Eon;Chung, Chun Kee;Jahng, Tae-Ahn;Kim, Chi Heon
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.151-156
    • /
    • 2013
  • Purpose: Traumatic cervical SCI is frequently accompanied by dural tear and the resulting cerebrospinal fluid (CSF) leak after surgery can be troublesome and delay rehabilitation with increasing morbidity. This study evaluated the incidence of intraoperative CSF leaks in patients with traumatic cervical spinal cord injury (SCI) who underwent anterior cervical surgery and described the reliable management of CSF leaks during the perioperative period. Methods: A retrospective study of medical records and radiological images was done on patients with CSF leaks after cervical spine trauma. Results: Seven patients(13.2%) were identified with CSF leaks during the intraoperative period. All patients were severely injured and showed structural abnormalities on the initial magnetic resonance image (MRI) of the cervical spine. Intraoperatively, no primary repair of dural tear was attempted because of a wide, rough defect size. Therefore, fibrin glue was applied to the operated site in all cases. Although a wound drainage was inserted, it was stopped within the first 24 hours after the operation. No lumbar drainage was performed. Postoperatively, the patients should kept their heads in an elevated position and early ambulation and rehabilitation were encouraged. None of the patients developed complications related to CSF leaks during admission. Conclusion: The incidence of CSF leaks after surgery for cervical spinal trauma is relatively higher than that of cervical spinal stenosis. Therefore, one should expect the possibility of a dural tear and have a simple and effective management protocol for CSF leaks in trauma cases established.

A Study on the Information Effluence State and Measure by Peer-to-Peer Programs in Korea and Japan (P2P프로그램을 통한 한국과 일본의 정보유출 현황 및 대책 연구)

  • Kim, Wan-Soo;Kim, Shik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.1
    • /
    • pp.67-74
    • /
    • 2009
  • Information Effluence leaks are caused by the wide use of the P2P program in Japan and Korea lead by the increase of internet use and network infrastructure expansion. This research confirms the seriousness of the data collected from the P2P leaks of the two countries and furthers its study by researching how countermeasures are applied. The effectiveness is verified by collecting data according to countermeasure applied periods. Both countries had information leaks, but in the case of Japan, not only personal information leaks but corporation, administrative agency, military, and others in a wide range as well. As a countermeasure against information effluence, Korea is enforcing counter plans mainly against the P2P service businesses and for Japan, various plans are taken such as business guides for each agency, organization management, SW development and supply, HW supply, and ect. The leaks in Japan were more severe than the ones in Korea but they had well planned countermeasures that were applied. Therefore if the Japanese countermeasure on information effluence of P2P programs is taken as a lesson, Korea can prevent the problem of leaks beforehand.

  • PDF

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Management of Bile Leaks from Bilateral Intrahepatic Ducts after Blunt Trauma (둔상성 외상 후 양측 간내 담관에서 담즙 누출의 치료 사례 1례)

  • Kim, Dong Hun;Choi, Seokho;Go, Seung Je
    • Journal of Trauma and Injury
    • /
    • v.27 no.3
    • /
    • pp.89-93
    • /
    • 2014
  • Bile leaks are complications that are much more frequent after a high-grade liver injury than after a low-grade liver injury. In this report, we describe the management of bile leaks that were encountered after angiographic embolization in a 27-year-old man with a high-grade blunt liver injury. He had undergone an abdominal irrigation and drainage with a laparotomy on post-injury day (PID) 16 due to bile peritonitis and continuous bile leaks from percutaneous abdominal drainage. He required three percutaneous drainage procedures for a biloma and liver abscesses in hepatic segments 4, 5 and 8, as well as endoscopic retrograde cholangiopancreatography with biliary stent placement into the intrahepatic biloma via the common bile duct. We detected communication between the biloma and the bilateral intrahepatic duct by using a tubogram. Follow-up abdominal computed tomography on PID 47 showed partial thrombosis of the inferior vena cava at the suprahepatic level, and the patient received anticoagulation therapy with low molecular weight heparin and rivaroxaban. As symptomatic improvement was achieved by using conservative management, the percutaneous drains were removed and the patient was discharged on PID 82.

Analysis on Signal Properties due to Concurrent Leaks at Two Points in Water Supply Pipelines (상수도 배관에서 두 지점의 동시 누수에 따른 신호특징 분석)

  • Lee, Young-Sup
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Intelligent leak detection is an essential component of a underground water supply pipeline network such as a smart water grid system. In this network, numerous leak detection sensors are needed to cover all of the pipelines in a specific area installed at specific regular distances. It is also necessary to determine the existence of any leaks and estimate its location within a short time after it occurs. In this study, the leak signal properties and feasibility of leak location detection were investigated when concurrent leaks occurred at two points in a pipeline. The straight distance between the two leak sensors in the 100A sized cast-iron pipeline was 315.6 m, and their signals were measured with one leak and two concurrent leaks. Each leak location was described after analyzing the frequency properties and cross-correlation of the measured signals.