• Title/Summary/Keyword: Leakage water

Search Result 894, Processing Time 0.026 seconds

THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION (응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

Analysis on the contamination and source of VOCs in groundwaters of Gwangju area (광주광역시의 지하수 중 휘발성유기화합물(VOCs)의 오염과 오염원 분석)

  • Yun, Uk;Cho, Byong-Wook;Eum, Chul-Hun;Sung, Ik-Hwan
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.389-404
    • /
    • 2003
  • VOCs were detected in the 21 groundwaters out of 37 groundwaters sampled from around the Hanam Industrial Complex and the Gwangju stream. Ten components of chlorinated aliphatic hydrocarbons of VOCs were detected in the 18 groundwater samples. Among them, total trihalomethanes (TTHM) concentration is in the range of $0.1~36.2{\;}\mu\textrm{g}/L$, CECs concentration is $2.3~190{\;}\mu\textrm{g}/L$, and chlorinated solvents concentration containing PCE, TCE, etc. is $0.1~124.2{\;}\mu\textrm{g}/L$ respectively. Ten components of the aromatic hydrocarbons of VOCs were detected in the 5 groundwater samples, but their concentration are less than $1{\;}\mu\textrm{g}/L$. Detection frequency and concentration of the chlorinated aliphatic hydrocarbons components from the groundwaters in the Hanam Industrial Complex are higher than those of nearby downtown Gwangju stream. VOCs components except for TCE are lower than the MCL of USGS drinking water standard. TCE concentration of the 2 groundwater samples is over MCL, whose concentrations are 5 and 25 times higher than MCL, respectively. TCE is detected from the H8 and H10 groundwater samples and CFCs is detected H8 and H11 groundwater samples in the Hanam Industrial Complex. TTHM in study area is estimated from leakage of the main waters or sewage waters. Because most of the studied groundwater is under an aerobic condition, aromatic hydrocarbons are well degraded. But chlorinated aliphatic hydrocarbons are degraded very slowly.

Fruit Quality of 'Wonhwang' Pear Trees with Low-pesticides and In Vitro Regrowth of Stem Cuttings as Affected by Time of Defoliation (시기별 적엽이 저농약 '원황'배의 과실품질과 삽수의 기내 재생장에 미치는 영향)

  • Kim, Byeong-Sam;Cho, Kyung-Chul;Ma, Kyung-Chul;Yun, Bong-Ki;Jung, Seok-Kyu;Han, Jeom-Hwa;Choi, Hyun-Sug
    • Korean Journal of Organic Agriculture
    • /
    • v.23 no.3
    • /
    • pp.469-480
    • /
    • 2015
  • The study was conducted on the effects of time of defoliation on fruit quality of pear (Pyrus pyrifolia Nakai) trees, managing with low-pesticides, and regrowth of stem cuttings in vitro. Treatments included for 40% of uniform defoliation at early-August, end-August, and early-September, as well as control (no defoliation). Defoliation at early-September and control increased growth of water sprouts as well as concentrations of carbohydrates, total nitrogen, and free sugar in one-year old shoots. Defoliation at early-September and control increased fruit yield and mean fruit weight, with high soluble solids content and fruit surface color of $a^*$ observed for both defoliation at end-August and early-September. Defoliation at early-August increased rates of electrolyte leakage in stem cuttings at $-18^{\circ}C$ in vitro. There were no significantly different for germination rates of the cuttings between the treatments at -18 and $-21^{\circ}C$ in vitro, with the highest germination of the cuttings observed for defoliation at early-September and control at $-27^{\circ}C$. Therefore, orchard management should be performed to be minimized for defoliation of the spur leaves until end-August, causing from precipitation and pests.

SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING (치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과)

  • Kim, Min-Jeong;Lee, Mi-Jeong;Yu, Mi-Kyung;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The purpose of this study was to compare the effect of surface sealing materials on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 after applying Single Bond. Following 7 days storage in distilled water at $37^{\circ}C$, the restorations were sealed as following systems : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. Then, toothbrush abrasion test was conducted using a wear testing machine. Surface roughness was measured by means of profilometer before and after toothbrushing and the results were statistically analysed by using a paired t-test and ANOVA. The bonded interfaces and the changes of surface roughness were examined by SEM. For microleakage test, specimens were stained in a $2\%$ methylene blue solution, then longitudinally sectioned and analyzed for leakage at occlusal and cervical interfaces using stereomicroscope. The results were statistically analysed by using a Kruskal-Wallis and Mann-Whitney U test. Surface roughness was increasing in all groups after toothbrushing, but no statistically significant differences. In SEM observation, surface sealant was partially retained and partially detached in bonded interfaces. Especially, microgap was identified in cervical margins. In microleakage test, there was better seal in the enamel region and a significant difference between groups at occlusal margin. Control group and Single Bond group had significantly better marginal seal at enamel margin than cervical margin.

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.

A Study on the Safety Code Development of Gas Engine Micro Combined Heat and Power System (소형 가스엔진 열병합 발전시스템 안전기준 개발)

  • Kwon, Jun-Yeop;Kim, Min-Woo;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2021
  • Recently, as a solution to the sharp drop in "power reserve ratio", it is being converted to a microgrid that enables bi-directional transmission and distribution. A microgrid is composed of a small-scale distributed power supply and a load. As a representative technology of distributed power generation, there is a Micro Combined Heat and Power system applied to homes and buildings. In this study, a safety standard was developed by dividing the power generation system, cooling system, lubrication system, and exhaust system to derive safety standards for a small gas engine power generation system with a gas consumption less than 232.6kW (200,000 kcal/h). In the case of the power generation system, a filter was installed and the system was stopped by detecting gas leakage and abnormalities in engine speed or output and the cooling system is stipulated to stop the system in case of insufficient cooling water or overheating. The lubrication system monitors the pressure and temperature of the lubricating oil and stops the system when an abnormality occurs, and the exhaust gas emission concentration regulation value was specified in accordance with domestic and foreign standards. Through the results of this study, it is judged that the safety of the gas engine power generation system can be improved and it can contribute to the commercialization of products.

Characteristics of Mine Liner According to the Replacement Ratio of Nano-Silica and Silica-Fume (나노실리카 및 실리카흄 대체율에 따른 차수재의 특성)

  • Kang, Suk-Pyo;Lee, Hee-Ra;Kang, Hye-Ju;Nam, Seong-Young;Kim, Chun-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.66-73
    • /
    • 2019
  • Approximately 80% of the mines are vacated or abandoned mines and are mostly left without suitable environmental treatment facilities. In the area around the abandoned mine site, problems such as drainage of acidic city drainage and leakage of leachate occur, and ground subsidence caused by this can cause a safety accident due to sink hole occurrence. In this study, flow, compressive strength, water uptake, pore and hydration characteristics were investigated to investigate the basic properties of liner and cover material based on the replacement ratio of nano silica and silica fume in the existing blast - furnace slag fine powder. As a result, as the substitution ratio of nano silica and silica fume increased, the flow and compressive strength of nano silica specimens increased and the absorption rate decreased. In the case of pore characteristics, the amount of pores decreased as the substitution ratio of nano silica and silica fume increased. Especially, the capillary porosity of 10-1,000 nm diameter decreased. Ray diffraction analysis and SEM measurement showed that the peak positions of the hydration products were almost the same when compared with the 5% alternative test samples of Plain and silica fume.

Evaluation of Freeze-Thaw Damage on Concrete Using Nonlinear Ultrasound (초음파의 비선형 특성을 이용한 콘크리트 동결융해 손상 평가)

  • Choi, Ha-Jin;Kim, Ryul-Ri;Lee, Jong-Suk;Min, Ji-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.56-64
    • /
    • 2021
  • Leakage due to deterioration and damage is one of the major causes of volume change by freezing and thawing, and it leads micro-cracking and surface scaling in concrete structures. The deterioration of damaged concrete accelerates with the chloride attack. Thus, in the detailed guidelines for facility performance evaluation (2020), the quality of cover concrete and the freeze-thaw (FT) repetition cycle were newly suggested for concrete durability assessment. The quality of cover concrete should be evaluated by the rebound hammer test and the FT repetition cycle should be also considered in the deterioration environmental assessment. This study suggested the application of fast dynamic based nonlinear ultrasound method to monitor initial micro-scale damage under freezing and thawing environment. Concrete specimens were fabricated with different water-cement ratios (40%, 60%) and air contents (1.5% and 3.0%). The compressive strength, rebound number, relative dynamic modulus, and nonlinear ultrasound were measured with different FT cycles. The scanning electron microscopy was also performed to investigate the micro-scale FT damage. As a result, both the rebound number and the relative dynamic modulus had difficulty to detect early damage but the proposed method showed a potential to detect initial micro-scale damage and predict the FT resistance performance of concrete.

Deep Learning-based Object Detection of Panels Door Open in Underground Utility Tunnel (딥러닝 기반 지하공동구 제어반 문열림 인식)

  • Gyunghwan Kim;Jieun Kim;Woosug Jung
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.665-672
    • /
    • 2023
  • Purpose: Underground utility tunnel is facility that is jointly house infrastructure such as electricity, water and gas in city, causing condensation problems due to lack of airflow. This paper aims to prevent electricity leakage fires caused by condensation by detecting whether the control panel door in the underground utility tunnel is open using a deep learning model. Method: YOLO, a deep learning object recognition model, is trained to recognize the opening and closing of the control panel door using video data taken by a robot patrolling the underground utility tunnel. To improve the recognition rate, image augmentation is used. Result: Among the image enhancement techniques, we compared the performance of the YOLO model trained using mosaic with that of the YOLO model without mosaic, and found that the mosaic technique performed better. The mAP for all classes were 0.994, which is high evaluation result. Conclusion: It was able to detect the control panel even when there were lights off or other objects in the underground cavity. This allows you to effectively manage the underground utility tunnel and prevent disasters.

Characterization of Durability and Deterioration Eroded by Chemical Attack on the Concrete Lining in Conventional Tunnel (화학적 침식을 받은 재래식 터널 콘크리트 라이닝의 내구성능 및 열화특성)

  • Kim, Dong-Gyou;Lee, Seung-Tae;Jung, Ho-Seop
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.25-32
    • /
    • 2007
  • This study is to evaluate the effect of chemical attack on durability and deterioration of lining concrete in tunnel. Surface examination, nondestructive inspection, uniaxial compressive strength test, carbonation test, chloride diffusion test, micro-structural analysis were performed to analyze the deterioration of lining concrete in tunnel constructed 70 years ago. From surface examination results, the tunnel had been repaired and reinforced in several times. It has many cracks, water-leakage, efflorescence and exploitation. Compressive strengths obtained from nondestructive inspection and uniaxial compressive strength test have measured $17.5{\sim}34.7MPa$, and $12.8{\sim}40.3MPa$, respectively. Carbonation depth specimen cored from concrete lining has ranged from 3mm to 27mm. From chloride diffusion test, most specimens have low permeability. And the XRD analysis was able to detect ettringite and thaumasite, which were confirmed by SEM and EDS results to be the causes for the deterioration of lining concrete.