• 제목/요약/키워드: Leakage type

검색결과 905건 처리시간 0.027초

수소충전소용 유압식 압축기 안전성 시험에 관한 연구 (Hydraulic Compressor Safety Test for Hydrogen Stations)

  • 성혜진;황봄찬;최성준;김영규;조성민
    • 한국기계가공학회지
    • /
    • 제19권11호
    • /
    • pp.8-15
    • /
    • 2020
  • The government has announced its Hydrogen Economy Roadmap to strengthen global competitiveness on the hydrogen economy by focusing on hydrogen fuel cell electric vehicles and fuel cells. In this regard, the interest on the economics and safety of the infrastructure of hydrogen stations has also increased. In this study, a test bed similar to an actual hydrogen charging facility was built, and a prototype of a piston-type compressor was modeled. In this model, the piston was hydraulically compressed to progressively test leakage, leakage rate, and durability and to check for any malfunction. Moreover, the leakage rate, cylinder leak performance, and compressor operation durability were evaluated for safety; it was confirmed that there were no abnormalities. Nevertheless, an investigation of the long-term use and operating pressure of the compressor is necessary to verify the safety of developing a100-MPa domestic compressor in the future.

포름알데히드 누출에 따른 대피장소 선정 방안 (The Selter Selection Plan due to Formaldehyde Leakage)

  • 오승주;공하성
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.117-129
    • /
    • 2023
  • This study tested the effect on the toxicity of formaldehyde to select a shelter site due to formaldehyde leakage. As a result of the experiment, the range of ERPG-2 and 3 is between 2.2km and 9.6km, ASET is 6 minutes at 1km, 15 minutes at 3km, 22 minutes at 5km, and the lethality rate is 99.9% at 1km and 9% at 3km. In areas where refuge time is less than 15 minutes or the lethality rate is more than 2%, a shelter is installed. This is because if there are only a few evacuees, the evacuation time may take longer than the pre-movement time of 15 minutes or less specified in PD 7974-6:2004, and the lethality rate with the lowest number of deaths was calculated to be 2%. The shelter must be equipped with a hepa-filter, positive pressure equipment, air purifier, air respirator, goggles, chemical protective clothing type 4 and sufficient parking space must be secured to ensure the safety of evacuees.

Investigation on helix type labyrinth seal to minimize leakage flow of cryogen for rotating superconducting machines

  • Yubin Kim;Kihwan Kim;Seungcheol Ryu;Hojun Cha;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제26권1호
    • /
    • pp.25-30
    • /
    • 2024
  • High-temperature superconducting rotors offer advantages in terms of output-to-weight ratio and efficiency compared to conventional phase conduction motors or generators. The rotor can be cooled by conduction cooling, which attaches a cryocooler, and by refrigerant circulation, which uses circulating liquid or gas neon, helium and hydrogen. Recent work has focused on environmental issues and on high-temperature superconducting motors cooled with liquid hydrogen that can be combined with fuel cells. However, to ensure smooth supply and return of the cryogenic cooling fluid, a cryogenic rotational coupling between the rotating and stationary parts is necessary. Additionally, the development of a sealing structure to minimize fluid leakage applicable to the coupling is essential. This study describes the design and performance evaluation of a non-contact sealing method, specifically a labyrinth seal, which avoids power loss and heat load caused by friction in contact sealing structures. The seal design incorporates a spiral flow path to reduce leakage using centrifugal force, and computational fluid dynamics (CFD) simulations were conducted to analyze the flow path and rotational speed. A performance evaluation device was configured and employed to evaluate the designed seal. The results of this study will be used to develop a cryogenic rotational coupling with supply and return flow paths for cryogenic applications.

위 수술 전후의 내시경 시술: 재건법에 따른 접근, 수술의 관점 (Endoscopy after Gastric Surgery: For Each Reconstruction Method, Operator's Point of View)

  • 주일석;조현진;최수인
    • Journal of Digestive Cancer Research
    • /
    • 제11권2호
    • /
    • pp.66-76
    • /
    • 2023
  • Endoscopy is an important noninvasive procedure for patients with gastrointestinal problems. However, surgical techniques are shifting to laparoscopic surgery, and changes in endoscopic findings after laparoscopic surgery differ from those after previous surgical methods. Postoperative endoscopic findings differ from normal anatomical structures, and findings reportedly vary depending on the type of surgical technique. Therefore, we aimed to summarize the surgical and endoscopic findings for each surgical method from the surgeon's point of view. The causes of gastric emptying delay, bleeding, afferent loop syndrome, or anastomosis leakage occurring after gastric cancer surgery can be identified via upper gastrointestinal endoscopy that is relatively less invasive than the surgical method. Regarding postoperative anastomosis leakage, endoscopy can directly evaluate the degree of leakage at the anastomosis site more accurately than computed tomography and enable immediate intervention. As endoscopy is less invasive than the surgical method, patients can be evaluated and treated more safely. However, coordination between the surgeon and the endoscopist is necessary to perform the procedures effectively. Therefore, reviewing the changes in surgical and endoscopic findings is important.

에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로 (Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Diode and MOSFET Properties of Trench-Gate-Type Super-Barrier Rectifier with P-Body Implantation Condition for Power System Application

  • Won, Jong Il;Park, Kun Sik;Cho, Doo Hyung;Koo, Jin Gun;Kim, Sang Gi;Lee, Jin Ho
    • ETRI Journal
    • /
    • 제38권2호
    • /
    • pp.244-251
    • /
    • 2016
  • In this paper, we investigate the electrical characteristics of two trench-gate-type super-barrier rectifiers (TSBRs) under different p-body implantation conditions (low and high). Also, design considerations for the TSBRs are discussed in this paper. The TSBRs' electrical properties depend strongly on their respective p-body implantation conditions. In the case of the TSBR with a low p-body implantation condition, it exhibits MOSFET-like properties, such as a low forward voltage ($V_F$) drop, high reverse leakage current, and a low peak reverse recovery current owing to a majority carrier operation. However, in the case of the TSBR with a high p-body implantation condition, it exhibits pn junction diode.like properties, such as a high $V_F$, low reverse leakage current, and high peak reverse recovery current owing to a minority carrier operation. As a result, the TSBR with a low p-body implantation condition is capable of operating as a MOSFET, and the TSBR with a high p-body implantation condition is capable of operating as either a pn junction diode or a MOSFET, but not both at the same time.

저속에서 피스톤 슈 내부 보조 링의 윤활 효과 분석 (Investigation of the Tribological Effects of the Auxiliary Inner Ring for Piston Shoes at Low Speeds)

  • 이성렬;김종혁;홍예선;김병곤;문진삼;문준혁
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권2호
    • /
    • pp.21-26
    • /
    • 2015
  • In order to design a swash plate type pump for electro-hydrostatic actuators the performance of the hydrostatic piston shoe bearings in the low speed range needs to be examined, since the pump operates frequently at low speeds, compensating for position control errors as a control element. As a common practice, piston shoes are equipped with inner rings as an auxiliary element to enhance their tribological performance. In this paper, the effects of the inner rings of the piston shoes on the frictional loss and leakage flow rate were investigated, where three piston shoe models, with different inner ring shapes and different inlet orifice sizes, were integrated. The test results showed that a large inner ring and small inlet orifice were advantageous for reducing both the frictional loss and leakage flow rate; this could also be confirmed by computational analyses.

이중구조팬의 Conic Winglet 최적설계 (Optimal Design for a Conic Winglet of a Dual Type Combined Fan)

  • 김진욱;김우택;류민형;조이상;조진수
    • 한국항공우주학회지
    • /
    • 제44권6호
    • /
    • pp.468-476
    • /
    • 2016
  • 본 연구에서는 이중구조를 갖는 팬의 날개 끝에서 발생하는 손실을 저감시키기 위하여 바깥 날개 끝 익형단면을 세 축으로 회전시키는 Conic winglet을 적용하였다. 손실을 계산하기 위하여 CFD 전산해석을 수행하였으며, 최소의 손실을 얻기 위하여 최적화를 수행하였다. 최적화 결과 Conic winglet은 바깥 날개 끝의 후단 부근에서 압력면 쪽으로 휘어진 형상을 보였으며 이 형상은 날개 끝에서 발생하는 전압력 손실을 3.24 % 저감시켰다.

종이 물성에 따른 판형 전열교환기의 성능 (Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties)

  • 김내현;조진표;송길섭;김동훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

3상 전압형 PWM 컨버터 운전시 전원측 리액터의 불평형을 고려한 보상법 (A Compensation Method considering Unbalance of Reactor at Source Side in Driving 3 Phase Voltage type PWM Converter)

  • 전지용;이사용;조유환;이근홍
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.373-379
    • /
    • 2005
  • 본 논문에서는 인버터를 구동하는 용도의 직류전원장치에 대한 제어 알고리즘 개발을 목표로 하고 있으며, 구동과 회생기능을 갖는 전압형 PWM 컨버터에서 운전시 전원의 불평형을 보상하는 제어방법을 제안한다. 교류전원에 대하여 컨버터가 항상 평형상태를 유지하는 방법은 전류제어 루프에 의하여 불평형 상태를 보상하는 방법을 사용하였으며, 불평형의 제어는 전력변환기의 구성면에 있어서 각상의 리액턴스가 같지 않은 누설변압기 등의 사용을 가능하게 하므로 제안된 전력변환기의 하드웨어와 제어 알고리즘은 장치의 소형화와 효율향상에 기여할 것이다.