• 제목/요약/키워드: Leakage safety

검색결과 845건 처리시간 0.035초

건축 구조물 외단열 시스템의 열화 및 누수현상이 구조물 노후화에 미치는 영향 분석에 관한 연구 - 초고층 oo 아파트 외벽 누수 사례를 통하여 - (Analysis the influence of the exterior insulation deterioration and water leakage on the aging of concrete structure)

  • 박연진;박진상;선윤숙;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.159-163
    • /
    • 2007
  • We studied the example of various side on effect the aging of exterior materials for concrete structure by analyzing the reason of water leakage in exist serviced skyscraper apartment. For this side, we would like to suggest the proper waterproofing materials and construction methods resulted in the mechanical performance test. So, it could be ensured the leakage safety for using residence facility and crowd utilization after repairing. It may maximize the durability for the concrete structure.

  • PDF

LPG 이송작업시 인적과오에 대한 사상수목분석

  • 김호영;김성영;임현교
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1998년도 춘계 학술논문발표회 논문집
    • /
    • pp.277-284
    • /
    • 1998
  • LPG refueling include a lot of risk done by human beings, dealing with highly combustible gas, so, during the refueling, the leakage initiated by human errors can result in a catastrophic accident. Therefore, this research tried to show what kind of tasks would include the high probability of the human errors and what should be considered for effective safety management in the LPG refueling. At first, 4 typical cases were taken through surveying various accident cases, and then a prototype of the refueling task was presented. And each task was analysed by FTA and ETA. The results showed that overpressure occupies 64.64% of the major reasons for gas leakage, and its probability was approximately 6.62E-06. Among the tasks, gas leakage resulted from mal-assembly of lorry hoses had the highest rate, and human errors related to opening and closing valves of pipe lines were most frequent. Also, the effects of confirming tasks were analyzed quantitatively.

  • PDF

재래시장 전기재해 감소를 위한 실시간 확인이 가능한 분전반 개발 (Development of the Cabinet Panel of Real-Time Availability Checks for Electrical Disaster Decreasing at Traditional Markets)

  • 김기현;이상익;신성수;배석명
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.335-339
    • /
    • 2010
  • In this paper, in order to reduce the electrical disaster damage which is caused by with electrical equipment of traditional markets, we developed the cabinet panel and the electrical safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage current, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electrical safety monitoring system and cabinet panel. And we tested the cabinet for over current, leakage current and arc under the traditional markets actual condition. This paper will be used with the data for an demonstration project after compensating the defects which are occurred to operation of traditional markets actual loads.

수소 취급설비의 폭발위험장소에 관한 연구 (A Study on Explosive Hazardous Areas in Hydrogen Handling Facility)

  • 표돈영;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제30권1호
    • /
    • pp.29-34
    • /
    • 2019
  • Safety of hydrogen handling facilities is needed as supply of hydrogen cars has been expanded recently. In this study, the adequacy of safety regulations of hydrogen handling facilities and the risk of damage with hydrogen leakage were studied. The range of explosion hazard location of the hydrogen filling plant was investigated using the computational fluid dynamics (CFD) method, Explosive hazardous area is influenced by leakage type, hole size and sectional area. When the conditions of KS standard are applied, range explosive hazardous area is expanded 7.05 m, maximum. It is about 7 times larger than exceptional standard of hydrogen station. Meanwhile, distance from leakage point to 25% LEL of hydrogen is investigated 1.6 m. Considering the shape of charging hose, regulation of hydrogen station is appropriate.

LPG 충전소의 가스누출에 따른 피해예측 및 감소방안 (Predicting and Preventing Damages from Gas Leaks at LPG Stations)

  • 양용호;공하성
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.577-585
    • /
    • 2023
  • 이 연구는 LPG 충전소의 가스누출로 발생이 예상되는 화재 및 폭발에 따른 피해예측에 ALOHA 프로그램을 적용 영향범위와 거리를 도식화함으로 피해방지 방안을 제시하였다. LPG 충전소에서 프로판 가스가 누출될 경우 LPG 충전소 주변지역 주민들에게 호흡곤란 등의 인명피해 및 건물파괴 등 재산피해를 입히는 것으로 나타났다. 이의 감소방안으로 첫째 LPG 충전소의 위험물안전관리자는 수시로 계측기와 안전밸브가 제대로 작동하는지 점검하여 누출을 사전에 방지할 필요가 있다. 둘째 LPG 충전소에서 저장탱크에 충전하는 작업은 위험물안전관리법 규정에 따라 "위험물안전관리자 교육"을 받고, 소방관서에서 "위험물안전관리자"로 선임된 사람의 책임하에 해야 한다는 것이다. 셋째 LPG차량의 과충전 방지장치 등 각종 안전장치의 기능을 평상시 정기적으로 점검할 필요가 있다. 마지막으로 LPG 충전소에 가스가 누출될 때 정전기에 의해 화재가 발생할 수 있으므로 정전기를 방지할 수 있는 작업복·작업화를 착용하는 등의 조치로 정전기발생을 억제하는 것이 바람직하다.

3D 스캔과 CFD를 활용한 LPG 폭발사고의 누출량 산정에 관한 연구 (A Study on Calculation of Leakage for LPG Explosion Accident using 3D Scan and CFD)

  • 조완수;김의수
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.1-7
    • /
    • 2018
  • Recently, various engineering approaches have been widely used in the accident investigation field to identify the cause of the accident and to predict damage by accident. Computational analysis is the most commonly used method of accident investigation technique. This technique is mainly used to identify the mechanism of the accident generation and to determine the cause when it is difficult to reproduce the situation at the time of the accident or when it is impossible to perform a reproduction experiment. In this study, The gas explosion analysis for LPG explosion accident generated by defect of the blocking action was performed to determine the accident object, gas leakage amount and predicted the damage caused by the accident using 3D laser scanner and FLACS program. We can quantify the explosive power by LPG gas accident and predict the gas leakage amount, damage by accident and evaluate the stability of the structure through this study. In the future, This method can be widely used in the field of gas safety by improving the reliability and validity of the analysis.

해양시추선용 경량수밀댐퍼 설계 (Design of a Light Weight Watertight Damper for Offshore Rigs)

  • 한승훈;장지성;지상원
    • 수산해양교육연구
    • /
    • 제28권5호
    • /
    • pp.1470-1477
    • /
    • 2016
  • This study has designed and evaluated the safety of watertight damper for Offshore Rigs. The watertight damper is an improved design for conventional DN 350 butterfly valve. Numerical analysis has been performed to investigate the safety factor and seat leakage of the designed 3-type disk dampers. The structure analysis results present the deformations, the equivalent stresses and the safety factor. It was confirmed that the designed disk, rib-disk and streamlined disk of watertight damper are safe enough in maximum operating pressure of 0.98MPa. The results show that the disk damper had the smallest maximum deformations and stress among 3-type disk dampers and the safety factor was 4.3. Therefore it is confirmed that the disk damper has the most excellent strength. Also linear static structural analysis was individually conducted for disk and body. The results show that the maximum disk deformation was larger than the body deformation, Therefore the disk damper is causes no seat leakage.

스마트 분전반 제작을 위한 작업 공정도 개발에 관한 연구 (A Study on the Development of a Work Operation Process Chart for Smart Distribution Board Fabrication)

  • 이병설;최충석
    • 한국안전학회지
    • /
    • 제32권3호
    • /
    • pp.15-20
    • /
    • 2017
  • This study presented the strength of the materials and parts for smart distribution board fabrication, and developed a work operation process chart for smart distribution board fabrication. This work operation process chart for smart distribution board fabrication complied with SPS-KEMC regulations, and the applicable range and object are less than 1,000 V and 1,000 Hz for the AC distribution board and less than 1,500 V for the DC distribution board. The power supply is 3 phase 4 wires ($3{\Phi}$ 4W), divided into a single phase circuit and a 3 phase circuit. In addition, the circuit was configured so that the leakage current flowing through the distribution line of the load could be monitored in real time by using the sensor module installed at the rear end of the circuit breaker. Therefore, the administrator can easily find the risk factor of the load since engineer can check the leakage current of each distribution line. In addition, if a leakage current greater than standard value flows, it is possible to generate an alarm against a short circuit and cut off the leakage current. The work operation process chart for the smart distribution board fabrication consists of the following steps: raw and subsidiary materials, sheet metal work, tube making, welding, painting, busbar fabrication, assembly and wiring, product inspection, shipment, etc. Moreover, symbols, ${\Delta}$, ${\nabla}$, ${\bigcirc}$, ${\Rightarrow}$, etc. were used according to the type of work and work progress so that workers can easily understand the progress of the work.

태양광 발전설비의 침수 시 설비영향 및 전기적 안전성 평가 (An Assessment on Effect of Facility and Electrical Safety During the Flooding of the Photovoltaic Power System)

  • 박찬엄;정진수;한운기;임현성;송영상
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.38-44
    • /
    • 2014
  • The photovoltaic power system is performing power generation by being installed in outdoors. Therefore it has the characteristics affected by environmental factors. In particular, if the solar power generation facility connected to the grid, the power can be generated continuously in a state of being secured operating voltage of the inverter and solar irradiation. In that case, if an abnormal situation such as flooding or heavy rains has occur, the possibility of electric shock or damage of facilities due to current leakage or a floating matters is present. In this paper, we performed electrical safety assessment about the connection part, junction box and cable of the solar module when the solar power system was flooded. we also assessed whether or not the leakage current is occurred in case of the cable was damaged. As a result, in case of the leakage current is large, we can be known that it is the risk of electric shock as well as cause of inverter damage.

멤브레인식 LNG 탱크벽체의 누설안전에 관한 수치해석적 연구 (Numerical Study on the Leakage Safety of the Membrane LNG Tank Wall)

  • 김청균;심종현
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.14-20
    • /
    • 2008
  • 본 논문에서는 멤브레인 내부탱크, 합판, PUF 보냉재, 또 다른 합판, 예응력 콘크리트(PC) 구조물로 건설된 LNG 저장탱크의 강도안전성을 4가지의 누설해석 파괴모델에 대해 수치적으로 해석하였다. $200,000\;m^3$의 저장용량을 갖는 탱크벽면을 통한 LNG의 누설기준은 열저항 온도해석의 핵심이론이다. 결국 누설 LNG의 초저온 온도가 외부탱크의 외측벽면에서 검출되면, 이것은 저장탱크의 벽면두께를 통해 누설되었다고 가정할 수 있다. 열저항법에 기초한 누설안전성 해석결과에 의하면 합판이나 PUF 등은 벽면을 통해 누설하는 LNG를 차단할 수 있지만, 이들 벽면은 누설 LNG의 압력에 의해 파괴되므로 누설안전성을 보장하지 못한다. 그러나, PC 외부탱크는 누설된 LNG 압력을 접해도 초기에는 견디지만, 시간이 경과하면서 누설된 LNG가 탱크벽체 내부로 계속 스며들어 벽체의 온도가 급격하게 떨어지면서 누설은 진행될 것으로 예상된다. 따라서 PC 외부탱크는 누설 LNG를 일정기간 체류시켜 LNG의 누설기간을 연장하는 효과를 제공할 뿐이다.

  • PDF