• Title/Summary/Keyword: Leakage rate

Search Result 940, Processing Time 0.023 seconds

Performance-based Evaluation for Efficiency of Landfill Liner Systems

  • Nguyen, The Bao;Lee, Chul-Ho;Lee, Jong-Sun;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.245-254
    • /
    • 2009
  • Efficiency of landfill liners system is usually evaluated based on leakage rate and mass flux. In this study, composite liner systems including the GCL(geosynthetic clay liner) composite liner, the Subtitle D liner, the Wisconsin NR500 liner, and the recently utilized double composite liner, which is a combination of the GCL composite liner and Subtitle D-type liner, have been examined. The leakage rate through circular and long defects in the geomembrane (GM) of the liner system was analyzed with the aids of analytical and numerical methods. For the mass flux criterion, contaminant transport through defects in the GM of landfill liners can be evaluated based on the calculated leakage rates. The diffusion rate of volatile organic compounds through intact landfill liners was evaluated by performing a one-dimensional numerical model. Cadmium and toluene were adoptted in the analyses as typical inorganic and organic substances, respectively, which will be chemical species encountered during landfill operation. The performance-based evaluation indicates that the double composite liner systems are superior to the other types of liner.

  • PDF

Analytical Methods of Leakage Rate Estimation from a Containment tinder a LOCA (냉각수상실 사고시 격납용기로부터 누출되는 유체유량 추산을 위한 해석적 방법)

  • Moon-Hyun Chun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.121-129
    • /
    • 1981
  • Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from the mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than tile mass leakage rate formula of CONTEMPT-LT.

  • PDF

Differences of Germination Rate, Degree of Solute Leakage and Water Uptake Rate of Soybean Seeds in Two Storage Periods (저장기간에 따른 콩종실의 발아율이, 용출정도 및 수분흡수율의 차이)

  • 손범영;박금룡;김석동;김수희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.1
    • /
    • pp.95-102
    • /
    • 1996
  • This investigation was conducted to investigate if germination rate, degree of solute leakage and water uptake rate of seeds are a meaningful information for the selection criteria among soybean genotypes and to find out their characteristics in the variable temperature and moisture conditions encounted during long-term warehouse storage. Germination rate in soybean sprouting box and petri dish differed largely among genotypes stored for twenty months but there was little difference when stored for eight months. Length of hypocotyl was shorter at twenty months of storage than at eight months. Degree of solute leakage of Paldalkong and Pulmuwon was twice higher than that of SS88038 lines at twenty months of storage. In 30 minutes after imbibition, water uptake rate in all genotypes stored for twenty months was faster than these stored for eight months, and water uptake rate in Paldalkong and Pulmuwon stored for eight months was 1.5 and 2 times faster than in SS88038 lines. In correlation coefficients, the germination ability and emergence exhibited significantly negative correlation with degree of solute leakage at twenty months of storage. Water uptake rate in soybean seeds stored for eight months had highly significant positive correlation with degree of solute leakage in 30 minutes and one hour after imbibition while for twenty months of storage, it had highly significant positive correlation with that in 30 minutes, one hour and three hours after imbibition. In eight months of storage, the number of open micropyle had positive correlation with water uptake rate at 30 minutes after imbibiton. But in seeds stored twenty months, it wasn't correlated with water uptake.

  • PDF

Allowable Leakage Rate of Spent Fuel and Conditioned Spent Fuel in compliance with ISO 12807 (ISO 12807에 따른 사용후핵연료 및 금속전환체의 허용 누설률)

  • 방경식;이주찬;주준식;서기석;김호동
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.609-613
    • /
    • 2003
  • The confinement of a storage system to accommodate spent fuel and radioactive material must be designed and estimated so that the storage system is safe during a storage period. The confinement can be estimated by calculation of the allowable leakage rate in compliance with ANSI Nl4.5 or ISO 12807. Accordingly, the allowable leakage rate was estimated in compliance with ISO 12807 in the case of storage of 24 PWR spent fuels and 24-conditioned spent fuels. In the case of the 24 PWR spent fuel assemblies, the allowable leakage rate was estimated as $7.43{\times}10_{-11}m_3/s$, in the case of the 24 conditioned spent fuel assemblies, the allowable leakage rate was estimated as $1.80{\times}10_{-10}m_3/s$. Therefore, the confinement condition in the storage of the conditioned spent fuel is easier than that for the storage of the PWR spent fuel.

  • PDF

A Study on the Mitigation of Threat Zones for Indoor Chlorine Release using Effective Leakage Areas of Building and Box Model (건물의 유효누출면적 및 박스모델을 이용한 염소 실내 누출의 위험지역 완화에 관한 연구)

  • Kwak, Sollim;Lee, Eunbyul;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2018
  • It is difficult to determine the outdoor toxic level of hazardous chemicals that are leaked in the building, since there are no efficient ways to calculate how much percentage of the leaked chemicals is released into the outdoor atmosphere. In address to these problems, we propose a reasonable box model that can quantitatively evaluate the mass rate of the indoor chlorine leakage into the outside of the building. The proposed method assumes that the indoor chlorine leakage is fully mixed with the indoor air, and then the mixture of the chlorine and indoor air is exfiltrated into the outside of the building through effective leakage areas of the building. It is found that the exfiltration rate of the mixture of the chlorine and indoor air is strongly dependent on the temperature difference between inside and outside the building than the atmospheric wind speed. As compared with a conventional method that uses a vague mitigation factor, our method is more effective to evaluate the outdoor toxic threat zone of the chlorine that are leaked in the building, because it can consider the degree of airtight of the building in the evaluation of the threat zone.

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.

Influence of Side Leakage Loss on the Performance of a Micro Positive Displacement Hydraulic Turbine (마이크로 용적형 수차의 측면누설손실이 성능에 미치는 영향)

  • Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.291-295
    • /
    • 2006
  • Recently, greenhouse effect by $CO_2$ gas emitted by use of fossil fuel causes earth environmental problem. As a countermeasure of the global warming. micro hydropower under 100kW becomes the focus of attention for its clean and renewable energy sources. Newly developed micro positive displacement hydraulic turbine shows high efficiency and good applicability for the micro hydropoewer. The purpose of this study is to clarify the influence of leakage loss and effective head on the performance of the positive displacement hydraulic turbine for the further improvement of the turbine performance. The results show that the turbine. with a smaller side clearance. has much higher efficiency than that with bigger side clearance and it can sustain the high efficiency under the wider range of operation conditions. The turbine torque is proportional to the effective head and independent of the flow rate. The leakage is also dependent on the effective head but nearly independent of the flow rate.

Mechanical Face Seal Performance Test for 75ton Class Turbopump (75톤급 터보펌프 기계평면 실의 작동 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.187-191
    • /
    • 2009
  • A leakage performance test and an endurance performance test of a 75 ton class turbopump mechanical face seal are performed using water under high speed and high temperature environment. A prototype mechanical face seal is manufactured for the purpose of sealing of fuel between a fuel pump and turbine. By simulating operating condition experimentally, the leakage rate and seal carbon wear rate are obtained to evaluate the performance of the prototype mechanical face seal. The test results show the acceptable leakage performance and reasonable wear tendency as well.

Numerical Analysis of a Tip Leakage Vortex in an Axial Flow Fan (축류홴 익단누설와류의 수치적 해석)

  • Jang, Choon-Man;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.404-411
    • /
    • 2003
  • Three-dimensional vortical flow and separated flow topology near the casing wall in an axial flow fan having two different tip clearances have been investigated by a Reynolds-averaged Wavier-Stokes (RANS) flow simulation. The simulation shows that the tip leakage vortex formed close to the leading edge of the blade tip on suction side grows in the streamwise direction. On the casing wall, a separation line is formed upstream of the leakage vortex center due to the interference between the leakage vortex and main flow. The reverse flow is observed between the separation line and the attachment line generated downstream of the trailing edge, and increased with enlarging tip clearance. The patterns of a leakage velocity vector including a leakage flow rate are also analyzed according to two tip clearances. It is noted that the understanding of the distribution of a limiting streamline on the casing wall is very important to grasp the characteristics of the vortical flow in the axial flow fan.

  • PDF

Characteristics of Leakage Flow on Regenerative Blower and Leakage-reducing Design for Performance Enhancement (재생형 블로워의 누설유동 특성과 누설유량 저감을 통한 성능 향상)

  • Choi, Min-Ho;Kim, Young-Hoon;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.57-63
    • /
    • 2011
  • Regenerative blower is suitable for hydrogen recirculation in fuel cell vehicle due to its capability of high pressure rise in single stage. Numerical models were applied to investigate inner gap leakage flow characteristics. A leakage flow in the inner gap is dominantly affected by pressure gradient. Therefore a blower with concentric channel type was suggested as one of modified models for reducing the inner gap pressure gradient. Also numerical results such as pressure rise, efficiency, leakage flow rate and torque were compared between modified and reference models. The performance of concentric channel type was improved as a result of reduced leakage flow.