• 제목/요약/키워드: Leakage monitoring

검색결과 319건 처리시간 0.025초

광파이버 누수센싱 시스템 개발에 관한 연구 (A Study on the Development of Optical-Fiber Water Leakage Sensing System)

  • 김영복
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.

변압기 누설전류 통합 감시장치 적용사례 (A study case on application of a total monitoring device of leakage current in transformer)

  • 이정은;최홍규;김용규;박형민;송영주;유해출
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.51-54
    • /
    • 2009
  • 변압기 누설전류 통합 감시 장치는 변압기 중성점 접지선에 흐르는 누설전류를 검출하여 실시간으로 모니터링이 가능한 장치로, 지정 값 이상의 누설전류가 검출되면 관리자에게 경보함으로써 전기적인 사고를 사전에 예방할 수 있다. 본 논문에서는 변압기 누설전류 통합 감시장치에 대해 설명하고 실제 변압기 누설전류 통합 감시장치가 설치된 수용가의 누설전류량 측정을 통해 안전성 여부를 판단하였다.

  • PDF

상수관망에서 누수탐지를 위한 역추적계산법 (Back Tracing Calculation Method for the Leakage Detection in Water Distribution System)

  • 권혁재
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.611-619
    • /
    • 2013
  • In this study, Back Tracing Calculation Method was developed to determine the leakage location and leakage amount. Previously developed determination method of monitoring location and newly developed Back Tracing Calculation Method were applied to the sample pipe network and real size pilot plant. After leakage was assumed in the pilot plant, leakage location and leakage amount could be traced by Back Tracing Calculation Method. From the results, it was found that Back Tracing Calculation Method can be applied for the leakage detection in water distribution system. Furthermore, this method can be applied for the pressure management or leakage detection as a pressure control method in water distribution system.

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

파워스펙트럼 분석을 이용한 누수탐지 모니터링 시뮬레이션 (Water Leakage Detection Monitoring Simulation using Power Spectrum Analysis)

  • 정경용
    • 한국콘텐츠학회논문지
    • /
    • 제13권1호
    • /
    • pp.48-54
    • /
    • 2013
  • IT융합기술의 발전에 따라 누수탐지를 위한 인프라스트럭처가 구축되면서, 파손된 관로의 위치 및 규모의 파악 기술이 부각되고 있다. 또한 상수도 시설의 누수로 인한 수자원의 고갈 때문에 효율적으로 누수를 탐지할 수 있는 방법이 시급하다. 본 논문에서는 파워스펙트럼 분석을 이용한 누수탐지 모니터링 시뮬레이션을 제안하였다. 제안한 누수탐지 모니터링 시뮬레이션에서 반사파 파형을 측정한다. 수집된 반사파 파형으로부터 변화율을 계산한다. 그리고 고속 퓨리에 변환을 이용한 파워 스펙트럼 분석은 누수의 크기와 반사파 파형의 상관관계를 평가한다. 이를 시뮬레이션의 논리적 타당성과 유효성을 검증하기 위해 실험적인 적용을 시도하고자 한다. 따라서 실시간 누수탐지를 제공하여 효율적인 관리에 대한 만족도와 서비스의 질을 향상시켰다.

댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구 (A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body)

  • 오석훈;김중열;박한규;김형수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구 (A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer)

  • 홍순석;박준열;이정은;최경한
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.106-113
    • /
    • 2010
  • 누설전류를 그대로 방치할 경우 전기로 인한 감전, 화재 등 여러 가지 재해요인이 될 수 있으므로 상시감시가 필요하다. 그러나 변전소 관리를 무인화 또는 순회점검으로 실시하는 곳이 대부분이므로 상시 감시에 어려움이 있어 사고발생시 원인을 즉시 제거하지 못하고 누설전류에 의해 비상발전기의 OCGR이 작동되어 ACB가 차단될 경우 비상발전기의 가동이 중지되는 문제점이 있다. 이러한 문제점을 방지하기 위해 변압기 저압측 중성점 접지선으로 귀환하는 누설전류를 실시간 모니터링할 수 있는 변압기 누설전류 통합 감시 장치를 제안하였다. 따라서 본 논문에서는 저압전로와 기기의 절연이 열화 또는 파괴되어 흐르는 누설전류의 영향을 시뮬레이션을 통해 알아보고 사례연구를 통해 통합 감시 장치의 우수성을 검증하였다.

CPLD칩을 이용한 다채널 가스누출 경보시스템의 설계 및 제작 (Design and Fabrication of multi-channel gas leakage monitoring system using CPLD)

  • 정도운;정완영;이덕동
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.925-928
    • /
    • 1999
  • A multi-channel gas leakage monitoring system was designed and fabricated by using CPLD(complex Programmable Logic .Device) for monitoring and controlling the leakage of natural gas from supplying-pipes under the ground. Fabricated SnO$_2$thick film gas sensor elements were attached on safeguard steel plate of natural gas supplying pipes, and the local monitoring system in this study received the signal from the gas sensors. The monitoring system was implemented by using CPLD chip to reduce the development time and implement simple one chip system. The time division multi-channel system received the input signal from individual gas sensor at one of divided times by multiplexor and signal processed sequentially. The system reduced the size of peripheral circuit resulted in implementation of creditable simple system.

  • PDF

주행 데이터 분석을 통한 수소버스 운행안전 모니터링 기법 연구 (Study of Hydrogen Bus Operational Safety Monitoring Method through Driving Data Analysis)

  • 이현미;이인식;이용주;장정아;김시우; 심소정
    • 자동차안전학회지
    • /
    • 제15권4호
    • /
    • pp.58-64
    • /
    • 2023
  • The adoption of hydrogen-powered Elec is expanding globally. Hydrogen is recognized as a potentially hazardous energy source, and safety assessment is crucial for the development of plans to supply hydrogen-powered electric buses. Hydrogen gas leakage can have a significant impact during bus operations, and continuous hydrogen leakage in hydrogen-powered vehicles can result in fatal accidents. In this study, information about hydrogen leakage is collected through sensors installed within the vehicles and is measured when the sensor detects a leak. The study also proposes the use of Pseudo Fuel Leakage (PFL, %) as an additional indicator for evaluating and monitoring hydrogen safety and leakage.

동적 위험 분석을 위한 사고확률 추정 방법에 관한 연구 (Estimation of Accident Probability for Dynamic Risk Assessment)

  • 박병철;임채옥;남인혁;신성철
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.315-325
    • /
    • 2023
  • Recently, various dynamic risk analysis methods have been suggested for estimating the risk index by predicting the possibility of accidents and damage. It is necessary to maintain and support the safety system for responding to accidents by continuously updating the probability of accidents and the results of accidents, which are quantitative standards of ship risk. In this study, when a LNG leakage that may occur in the LN G Fuel Gas Supply System (FGSS) room during LN G bunkering operation, a reliability physical model was prepared by the change in monitoring data as physical parameters to estimate the accident probability. The scenario in which LNG leakage occur were configured with FT (Fault Tree), and the coefficient of the covariate model and Weibull distribution was estimated based on the monitoring data. The possibility of an LNG leakage, which is the top event of FT, was confirmed by changes in time and monitoring data. A method for estimating the LNG leakage based on the reliability physical analysis is proposed, which supports fast decision-making by identifying the potential LNG leakage at the accident.