• Title/Summary/Keyword: Leakage management

Search Result 657, Processing Time 0.025 seconds

A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System (가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰)

  • Yu, Won-Ju;Lee, Seong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.75-82
    • /
    • 2010
  • Gas turbines for power generating operate in a very high temperature condition and use natural gas for fuel. For this reason, many cases of damage happen at hot gas parts which are severely affected by high temperature gas and many cases of explosion occur by fuel gas. So a lot of efforts should be made to prevent hot gas parts damage and gas explosion accidents. Though there are many damage cases and explosion accidents, it is very difficult to find out the root causes of hot gas parts damage caused by gas explosion due to gas leakage in the heat exchanger for air cooling and gas heating. To prevent gas turbine from damage caused by gas explosion, removal of leakage gas from gas turbine is inevitably required before firing the gas turbine and installing alarm systems is also required for detecting gas leakage at stop valve to turbine while shut down.

The Development of Android Application for Intelligent Concent (지능형 콘센트를 위한 안드로이드 어플리케이션 개발)

  • Han, Young-Oh;Kim, Dong-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1515-1521
    • /
    • 2013
  • In this paper, we develop the power management application of the Android operating system that works with a intelligent concent having the functions to protect resistive leakage current, over-current and standby power. Using this power management application a user monitors electrical fire, shock from a concent due to leakage current, can control home appliances by controlling the power supplied to the concents and can easily protect wasted standby powers, anytime and anywhere.

A Design of KVM Heap Memory Management for Effective Power Management in Banked Memory System (Banked Memory System에서 효율적일 전력관리를 위한 KVM의 힙 메모리 관리체계 설계)

  • Choi In-Bum;kang Hui-Sung;Jeong Myung-Jo;Lee Cheol-Hoon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.868-870
    • /
    • 2005
  • 최근에는 자원이 제한적인 시스템을 위한 embedded JVM 환경에서 자바 응용 프로그램을 수행할 때 embedded JVM 의 성능에 따른 performance 뿐만 아니라 에너지 소비를 줄이는 일이 크게 대두되고 있다. 메모리에서 사용되는 에너지는 메모리에 접근할 때마다 소비되는 dynamic energy와 메모리에 파워가 들어와 있을 때 항상 소비되는 leakage energy 로 구분할 수 있다. embedded 환경을 고려하지 않았던 이전에는 leakage energy 가 중요한 부분으로 인식되지 않았지만, 현재는 dynamic energy 못지 않게 중요한 부분으로 인식되고 있다. 본 논문에서는 Banked Memory System을 사용하는 임베디드 JVM의 환경하에서 leakage energy를 효과적으로 줄일 수 있는 KVM의 힙 메모리 관리체계를 설계하였다.

  • PDF

Estimation of background minimum night flows by metering water use in water distribution areas (야간사용량 측정을 통한 배급수구역 배경야간최소유량 산정)

  • Lee, Doo-Jin;Kim, Do-Hwan;Kim, Ju-Hwan;Kim, Kyoung-Pil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.495-508
    • /
    • 2010
  • The aim of this study is to develop a quantified water loss Index to evaluate and manage leakage scientifically for the reduction of non-revenue water in water distribution systems. For the purpose, unavoidable background leakage suggested from UK water industry and IWA, and allowable water leakage in accord with the concept of allowable water loss are proposed by analyzing the inflow into two study water districts and the short-term water use of each customer in the districts. The study distribution areas are selected among the metered districts with good maintenance of leakage after improvement activities in Nonsan, medium sized city in Korea. Estimation models of allowable leakage are developed by metering and analyzing the minimum night flow at residential and commercial areas in the city. In the results of the investigation, it is estimated that background night flow in residential area was larger than that of commercial area where the types of business shows small water use characteristics. Meanwhile, night flow and background water loss on internal plumbing systems show great differences for each district which is influenced much by the water use characteristics and facilities scale. Based on metering water use data in various districts, leakage management criteria can be established under the consideration of domestic conditions in Korea by analyzing separated real water use and background leakage and it is possible to apply into presentation of optimal leakage level and reasonable time for working activities for leakage reduction.

The Study of Improvement of Personal Information Leakage Prevention in Mobile Environment (모바일 환경에서 개인정보 유출 방지를 위한 개선 연구)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.3
    • /
    • pp.53-62
    • /
    • 2015
  • Recently, number of tablet or Smartphone users increased significantly in domestic and around the world. But violation of personal information such as leakage, misuse and abuse are constantly occurring by using mobile devices which is very useful in our society. Therefore, in this paper it will talk about the problems in the network environment of the mobile environment such as tablet and Smartphone, Mobile Malware, hacking of the public key certificate, which could be potential threat to mobile environment. This thesis will research for people to use their mobile devices more reliable and safer in mobile environment from invasion and leakage of personal information. In order to use Smartphone safely, users have to use Wi-Fi and Bluetooth carefully in the public area. This paper will research how to use App safely and characteristic of risk of worm and Malware spreading. Because of security vulnerabilities of the public key certificate, it will suggest new type of security certification. In order to prevent from the information leakage and infect from Malware in mobile environment without knowing, this thesis will analyze the improved way to manage and use the mobile device.

The Selter Selection Plan due to Formaldehyde Leakage (산화프로필렌의 누출영향평가에 따른 안전거리 산정)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.11-22
    • /
    • 2024
  • This study aims to present safety distances by the damage impact assessment of the leakage of propylene oxide. As a result of the experiment, the pressure 1psi range was 52m to 169m, the radiant heat 18kW/m2 range was 63m to 163m, the AEGL-2 range was analyzed as 224m to 414m, and the fire ball diameter was analyzed to be 45m to 121m. Additionally, the extent of damages was proportional to the amount of propylene oxide stored or handled. The safe distance for a 10% lethality due to overpressure and radiant heat was calculated to be 134m, and the safe distance for a 0% lethality was 169m. Toxicity was measured at 134m with a lethality 0%. Therefore, the safety distance due to leakage of propylene oxide is calculated to be between 134m and 169m.

Management of Intractable Cerebrospinal Fluid Collection after Cerebellar Tumor Resection: A Case Report (소뇌 종양 적출 후 두개강 내 발생한 난치성 뇌척수액 고임의 치험례)

  • Rha, Eun Young;Oh, Deuk Young;Kim, Hye Young;Lee, Jung Ho;Moon, Suk Ho;Seo, Je Won;Rhie, Jong Won;Ahn, Sang Tae
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.95-98
    • /
    • 2010
  • Purpose: CSF (Cerebrospinal fluid) leakage is the most common complication of neurosurgery. Early management with conservative care or surgery must be followed appropriately due to the increased risk of lethal complications, such as meningitis. We report a case of intractable CSF leakage that occurred after a cerebellar tumor resection, which was treated successfully. Methods: A 53-year old male consulted our department for continuous CSF leakage for 3 months after having received conservative care and lumbar drainage. CSF collection was observed in the dead space of the posterior fossa after a cerebellar tumor resection and postoperative radiotherapy. Using a free latissimus dorsi muscle flap, the dead space within the skull was filled and the defects were covered successfully. Results: At 6 weeks after surgery, the follow-up MRI and CT revealed proper coverage and filling in the area where cerebellar tumor had been removed. No CSF leakage was observed at the postoperative 3 month follow-up. Conclusion: Recurrent CSF leakage was treated after cerebellar tumor resection with a relatively satisfactory result. In terms of the patient's treatment, much better results can be achieved by performing dead space filling using a flap with a sufficient size, in addition to coverage of the defects of the dura.

A Study on a Scenario-based Information Leakage Risk Response Model Associated with the PC Event Detection Function and Security Control Procedures (PC 이벤트 탐지 기능과 보안 통제 절차를 연계시킨 시나리오 기반 금융정보유출 위험 대응 모델에 관한 연구)

  • Lee, Ig Jun;Youm, Heung Youl
    • The Journal of Society for e-Business Studies
    • /
    • v.23 no.4
    • /
    • pp.137-152
    • /
    • 2018
  • It is a measure to overcome limitations that occur in the activity of detecting and blocking abnormal information leakage activity by collecting the activity log generated by the security solution to detect the leakage of existing financial information and analyzing it by pattern analysis. First, it monitors real-time execution programs in PC that are used as information leakage path (read from the outside, save to the outside, transfer to the outside, etc.) in the PC. Second, it determines whether it is a normal controlled exception control circumvention by interacting with the related security control process at the time the program is executed. Finally, we propose a risk management model that can control the risk of financial information leakage through the process procedure created on the basis of scenario.

Calculation of the target revenue water ratio of local waterworks considering economic feasibility (경제성을 고려한 지방상수도 목표 유수율 산정)

  • Donghong Kim;Jaebum Lee;Jungkwan Song;Taeho Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.311-324
    • /
    • 2023
  • As an advanced study on the method of calculating the target revenue water ratio of local waterworks through the leakage component analysis method proposed by Kim et al. (2022), this study developed a model to calculate the achievable revenue water ratio within the specified project cost, the required project cost to achieve the specified target revenue water ratio, and the economically appropriate target revenue water ratio level by considering the leakage reduction cost and leakage reduction benefit for each revenue water ratio improvement strategy, and conducted an applicability evaluation of the developed model using actual field data. The procedure for calculating the target revenue water ratio of local waterworks considering economics proposed in this study consists of three stages: physical data linkage model construction, leakage component analysis, and economic analysis, and the applicability was evaluated for Zone H with branch type and the Zone M network type. As a result of the application, it was calculated that approximately 32.5 billion won would be required to achieve the target revenue water ratio of 70% in the Zone H, and approximately KRW 10.5 billion would be required to achieve the target revenue water ratio of 75% in the Zone M. If the business scale of Zones H and M was corrected to 10,000 m3/day of water usage, the required project cost for a 1% improvement in the revenue water ratio of Zone H was calculated to be 0.7642 billion won and 0.4715 billion won for Zone M.

Assessment on Aging Management of Delayed Neutron Monitoring System Tubing for Continued Operation of Wolsong Unit 1 (월성1호기 계속운전 관련 결함연료위치탐지계통 배관의 열화관리평가)

  • Song, Myung Ho;Kim, Hong Key;Lee, Young Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.2
    • /
    • pp.14-20
    • /
    • 2011
  • The end of design lifetime for Wolsong unit 1 will be reached on 20th November in 2012. So the license renewal documents for the continuous operation of Wolsong unit 1 is under reviewing now. Major components of primary system such as pressure tubes, feeder pipes including delayed neutron monitoring system tubing are being replaced and many components of secondary system are also being repaired. In this paper, the assessment on the wear degradation of delayed neutron monitoring system tubing(on the other hand, DN tube was called) was performed for the ageing management of the same component. The wear defects of this component was one of causes that resulted in heavy water leakage accidents. Therefore design specifications of Wolsong uint 1 and heavy water leakage accidents of pressurized heavy water reactors were reviewed and causes of wear defect for DN tubes were analyzed. Wear propagation equations based on the heavy water leakage history were made and the proper repairing time was possible to be expected if the continued operation was considered. Finally design change items of DN tubes that were conducted for the long term operation of Wolsong unit 1 are introduced.