• 제목/요약/키워드: Leakage inductance

검색결과 242건 처리시간 0.026초

코어없는 초박형 PCB 변압기를 이용한 무접점 전력변환 회로 (A Contactless Energy Transfer Circuit Using Coreless Low-profile PCB Transformer)

  • 최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.505-508
    • /
    • 2000
  • A coreless printed circuit board(PCB) transformer is employed in a contactless energy transfer circuit that achieves an efficient power conversion at the presence of a considerable airgap between the source and the load side. A half-bridge series resonant converter is selected as the contactless energy transfer circuit in order to minimize the detrimental effects of large leakage inductance small magnetizing inductance and poor coupling coefficient of the coreless PCB transformer. The operation and performance of the proposed contactless power converter are verified on a 7 W experimental circuit that provides an 18V/0.4A output from a 210-370 V input source.

  • PDF

유도전동기의 매개변수 측정과 토크 모니터링 시스템 (Parameter Measurement and Torque Monitoring System for Induction Motors)

  • 김진우;김규식;권원태;박진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.131-134
    • /
    • 2001
  • The accurate identification of the motor parameters is crucially important to achieve high dynamic performance of induction motors. In this paper, the motor parameters such as rotor resistance, stator(rotor) leakage inductance, mutual inductance are measured for torque monitoring and indirect vector control. To demonstrate the practical significance of the results, some experimental results are presented.

  • PDF

Estimation of the Separate Primary and Secondary Leakage Inductances of a Y-Δ Transformer Using Least Squares Method

  • Kang, Yong-Cheol;Lee, Byung-Eun;Hwang, Tae-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.538-544
    • /
    • 2010
  • This paper proposes an estimation algorithm for the separate primary and secondary leakage inductances of a three phase $Y-\Delta$ transformer using least squares method. The voltage equations from the primary and secondary windings are combined into a differential equation to estimate the separate primary and secondary leakage inductances in order to use the line current of the delta winding. Separate primary and secondary leakage inductances are obtained by applying least squares method to the differential equation. The performance of the proposed algorithm is validated under transient states, such as magnetic inrush and overexcitation, as well as in the steady state with various cut-off frequencies of low-pass filter. The proposed technique can accurately generate separate leakage inductances both in the steady and transient states.

플라이백 컨버터에서 누설인덕턴스 저장에너지의 새로운 회복회로 (A Novel Recovery Circuit of a Leakage Inductance Stored Energy in Flyback Converter)

  • 정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.526-528
    • /
    • 2005
  • Nowadays, more than ever before, many researchers are paying attention to raising the efficiency of a Power converter. In Flyback converter, the resistor of RCD snubber consumes the stored energy in leakage inductor. It play a role in degrading the overall system efficiency Thus, In this paper, a novel energy recovery circuit of Flyback converter is proposed to improve the efficiency. The operational principle of the proposed circuit is explained in detail. And, it is verified through the simulation results.

  • PDF

권선구조에 따른 IPT transformer 해석 (The analysis of IPT transformer by winding structures)

  • 한경희;이병송;권삼영;박현준;백수현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.916-921
    • /
    • 2007
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the electric railway vehicle system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The inductive power of secondary part is related to amount of linked flux to secondary part by the length of air-gap, which is expected by such a system parameter as mutual inductance. This paper will study for the transfer characteristic of power from input to output and equation including mutual inductance. And also, effect of leakage inductance variation of inductive power collector according to structure of winding was considered.

  • PDF

권선형상에 따른 유도전력공급장치 특성해석 (The analysis of IPT transformer by winding structures)

  • 한경희;이병송;권삼영;박현준;이형우;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1259-1260
    • /
    • 2007
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the electric railway vehicle system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The inductive power of secondary part is related to amount of linked flux to secondary part by the length of air-gap, which is expected by such a system parameter as mutual inductance. This paper will study for the transfer characteristic of power from input to output and equation including mutual inductance. And also, effect of leakage inductance variation of inductive power collector according to structure of winding was considered.

  • PDF

매입형 영구자석 전동기의 파라미터 검증을 위한 인덕턴스 산정 (The Calculation of Inductance to verify the Parameters in Interior Permanent Magnet Motor)

  • 이석희;이상호;반지형;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.783-784
    • /
    • 2006
  • In case of a difference exist between the experimental value and estimated value of back-emf, there can be a difference of turn number or residual flux density of permanent maget of the motor. In order to presume the turn number, the average length for each coil is used to calculate the resistance. However in producing the motor, doc to the tension of coil, the outer diameter of coil becomes smaller, and then the resistance estimated by average length for each coil is not correct. Therefore in this paper, through the comparison of experiment value and estimated value of inductance, a method of presuming the turn number and PM's residual flux density of an IPM motor is presented. The inductance of IPM motor changes with the rotor position, therefore the rotor part is taken out and then the inductance in open circuit condition is measured. In the analytical calculation, 3D FEM(Finite Element Method) is used, which can consider the leakage flux of end turns in frinzing effect.

  • PDF

High Step-up Active-Clamp Converter with an Input Current Doubler and a Symmetrical Switched-Capacitor Circuit

  • He, Liangzong;Zeng, Tao;Li, Tong;Liao, Yuxian;Zhou, Wei
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.587-601
    • /
    • 2015
  • A high step-up dc-dc converter is proposed for photovoltaic power systems in this paper. The proposed converter consists of an input current doubler, a symmetrical switched-capacitor doubler and an active-clamp circuit. The input current doubler minimizes the input current ripple. The symmetrical switched-capacitor doubler is composed of two symmetrical quasi-resonant switched-capacitor circuits, which share the leakage inductance of the transformer as a resonant inductor. The rectifier diodes (switched-capacitor circuit) are turned off at the zero current switching (ZCS) condition, so that the reverse-recovery problem of the diodes is removed. In addition, the symmetrical structure results in an output voltage ripple reduction because the voltage ripples of the charge/pump capacitors cancel each other out. Meanwhile, the voltage stress of the rectifier diodes is clamped at half of the output voltage. In addition, the active-clamp circuit clamps the voltage surges of the switches and recycles the energy of the transformer leakage inductance. Furthermore, pulse-width modulation plus phase angle shift (PPAS) is employed to control the output voltage. The operation principle of the converter is analyzed and experimental results obtained from a 400W prototype are presented to validate the performance of the proposed converter.

LLC 직렬공진 컨버터 동작특성 (Operating Characteristics of LLC Series Resonant Converter)

  • 강성인;윤광호;박준호;허동영;김은수
    • 전력전자학회논문지
    • /
    • 제12권6호
    • /
    • pp.472-482
    • /
    • 2007
  • 본 논문에서는 PDP TV 전원에 적용된 LLT 변압기를 사용한 LLC 직렬공진 컨버터의 설계과정과 실험결과에 대해 서술하였다. 인덕터와 변압기를 하나의 변압기로 사용한 LLT 변압기는 전선방법과 코어의 공극에 따라 1, 2 차측 누설인덕턴스가 함께 증가한다. 이러한 LLT 변압기의 증가된 1, 2차측 누설인덕턴스는 LLC 직렬공진컨버터의 DC 전압이득에 영향을 준다. 따라서 본 논문에서는 LLT 변압기 적용 LLC 직렬 공진 컨버터의 전압이득 특성과 실험 결과에 대해 Math-CAD 시뮬레이션을 기본으로 한 이론적인 해석 및 600W 시제품을 통해 증명하였다.

Flat Transformer를 적용한 고밀도 전원장치 설계 (Design of the High Density Power Supply with Flat Transformer)

  • 백주원;김종현;유동욱;김종수;류명효
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.248-256
    • /
    • 2005
  • 본 논문에서는 중$\cdot$대용량 고밀도 전원 장치에 적합한 플랫 트랜스포머(Flat Transformer)를 사용하여 다양한 출력의 DC/DC 변환장치를 설계하는 방법을 제시하였다. 플랫 트랜스포머 모듈은 다수의 트랜스포머를 병렬로 구성하여 제작하고, 이차 권선이 항상 1턴으로 구성되므로 기존의 트랜스포머에 비해 누설 인덕턴스가 크게 감소하게 되어 고주파 스위칭에 적합한 형태를 가지고 있다. 본 논문에서는 플랫 트랜스포머의 성능을 증명하기 위하여 750W급 AC/DC 변환기를 구성하여 다양한 출력을 갖는 전원 장치를 제작/실험하였다.