• Title/Summary/Keyword: Leakage indicators

Search Result 35, Processing Time 0.028 seconds

Assessment of water use vulnerability in the unit watersheds using TOPSIS approach with subjective and objective weights (주관적·객관적 가중치를 활용한 TOPSIS 기반 단위유역별 물이용 취약성 평가)

  • Park, Hye Sun;Kim, Jeong Bin;Um, Myoung-Jin;Kim, Yeonjoo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.8
    • /
    • pp.685-692
    • /
    • 2016
  • This study aimed to develop the indicator-based approach to assess water use vulnerability in watersheds and applied to the unit watershed within the Han River watershed. Vulnerability indices were comprised of three sub-components (exposure, sensitivity, adaptive capacity) with respect to water use. The indicators were made up of 16 water use indicators. Then we estimated vulnerability indices using the Technique for Order of Preference by Similarity to Ideal Solution approach (TOPSIS). We collected environmental and socio-economic data from national statistics database, and used them for simulated results by the Soil and Water Assessment Tool (SWAT) model. For estimating the weighted values for each indicator, expert surveys for subjective weight and data-based Shannon's entropy method for objective weight were utilized. With comparing the vulnerability ranks and analyzing rank correlation between two methods, we evaluated the vulnerabilities for the Han River watershed. For water use, vulnerable watersheds showed high water use and the water leakage ratio. The indices from both weighting methods showed similar spatial distribution in general. Such results suggests that the approach to consider different weighting methods would be important for reliably assessing the water use vulnerability in watersheds.

A Signal Processing Technique for Predictive Fault Detection based on Vibration Data (진동 데이터 기반 설비고장예지를 위한 신호처리기법)

  • Song, Ye Won;Lee, Hong Seong;Park, Hoonseok;Kim, Young Jin;Jung, Jae-Yoon
    • The Journal of Society for e-Business Studies
    • /
    • v.23 no.2
    • /
    • pp.111-121
    • /
    • 2018
  • Many problems in rotating machinery such as aircraft engines, wind turbines and motors are caused by bearing defects. The abnormalities of the bearing can be detected by analyzing signal data such as vibration or noise, proper pre-processing through a few signal processing techniques is required to analyze their frequencies. In this paper, we introduce the condition monitoring method for diagnosing the failure of the rotating machines by analyzing the vibration signal of the bearing. From the collected signal data, the normal states are trained, and then normal or abnormal state data are classified based on the trained normal state. For preprocessing, a Hamming window is applied to eliminate leakage generated in this process, and the cepstrum analysis is performed to obtain the original signal of the signal data, called the formant. From the vibration data of the IMS bearing dataset, we have extracted 6 statistic indicators using the cepstral coefficients and showed that the application of the Mahalanobis distance classifier can monitor the bearing status and detect the failure in advance.

A Study on the Method of Energy Evaluation in Water Supply Networks (상수관망의 에너지 평가기법에 관한 연구)

  • Kim, Seong-Won;Kim, Dohwan;Choi, Doo Yong;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.7
    • /
    • pp.745-754
    • /
    • 2013
  • The systematic analysis and evaluation of required energy in the processes of drinking water production and supply have attracted considerable interest considering the need to overcome electricity shortage and control greenhouse gas emissions. On the basis of a review of existing research results, a practical method is developed in this study for evaluating energy in water supply networks. The proposed method can be applied to real water supply systems. A model based on the proposed method is developed by combining the hydraulic analysis results that are obtained using the EPANET2 software with a mathematical energy model on the MATLAB platform. It is suggested that performance indicators can evaluate the inherent efficiency of water supply facilities as well as their operational efficiency depending on the pipeline layout, pipe condition, and leakage level. The developed model is validated by applying it to virtual and real water supply systems. It is expected that the management of electric power demand on the peak time of water supply and the planning of an energy-efficient water supply system can be effectively achieved by the optimal management of energy by the proposed method in this study.

Clinical Analysis of the Surgical Treatments for Large Primary Spontaneous Pneumothorax (외과적 치료를 시행한 대량 일차성 자연기흉의 임상분석)

  • Kim, Byung-Ho;Huh, Dong-Myung;Han, Won-Kyung
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.344-349
    • /
    • 2009
  • Background: The clinical history and physical findings of the patients with spontaneous pneumothorax depend largely on the extent of the collapse of the lung and the presence of pre-existing pulmonary disease. Large primary spontaneous pneumothorax is a possible serious condition and. so more active treatment will be necessary for these patients. The therapeutic guideline for large pneumothorax remains controversial. Therefore, by assessing the clinical results of surgical treatment for large primary pneumothorax, we aim to determine the indicators of treatment. Material and Method: Among 348 patients with primary spontaneous pneumothorax and who underwent surgical treatment from August 2004 through December 2007, 58 patients who responded to treatment for a large primary pneumothorax were included in the current study. We then retrospectively evaluated the operative findings and the surgical results. The patients with a pneumothorax of 80% or more, including those patients with tension pneumothorax, were considered to have a "large pneumothorax". Most of these patients Should be treated with a 12F chest tube. Thoracoscopic wedge resection was considered for treating recurrent pneumothorax, continuous air leakage, controlateral pneumothorax and first episode pneumothorax with visible blebs (> 1cm) seen on the computed tomography. Result: There were 50 men and 8 women with a mean age of 28.2 years (range: $14\sim54$ years). The mean length of hospitalization was 5.3 days (range: $2\sim10$ days). Nine patients underwent chest tube drainage only. Forty-nine patients underwent thoracoscopic wedge resection. The mean follow up time was 27.8 months (range: $10\sim58$ months). The actual site of air leakage could be located in 35 patients (71.4%) and this was correlated with pleural adhesion (p=0.005). The initial air leakage tended to be more correlated with intra-operative air leakage, although this was not statistically significant (p=0.066). The recurrence rate was 11.1 % for the patients with chest tube drainage and 2.0% for the patients with thoracoscopic wedge resection. Conclusion: Large primary pneumothorax requires an early diagnosis and early treatment. Thoracoscopic wedge resection may help to prevent recurrence of large primary pneumothorax.

Responses of nutrient uptake, carbohydrates and antioxidants against low temperature in plants (저온에 대한 식물의 양분흡수, 탄수화물 및 항산화 반응 특성)

  • Lee, Suyeon;Jung, Jungah;Sung, Jwakyung;Ha, Sangkeun;Lee, Deogbae;Kim, Taewan;Song, Beomheon
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.2
    • /
    • pp.75-83
    • /
    • 2014
  • Recently, a quick drop of air temperature in plastic film houses by adverse weather conditions leads to the occurrence of low temperature damages to growing crops. Chilling injury, defined as a variety of growth restriction occurring below the optimal temperature, is one of environmental factors strongly affecting crop growth and yield. Low temperature causes the restricted evapotranspiration, reduced mineral uptake (P > K > $NO_3{^-}$), and an increase in electrolyte leakage such as K. Despite being different with plant species, an accumulation of soluble carbohydrates such as glucose, fructose, sucrose and starch under chilling condition is well known. A variety of environmental stresses are known to cause oxidative damage to plants either directly or indirectly by triggering an increased level of production of reactive oxygen species (ROS), and, to combat the oxidative damage, plants have the antioxidant defense systems comprising of enzymes, SOD, POD, CAT, GPX and APX, and non-enzymes, ascorbate, gluthathione, ${\alpha}$-tocopherol, phenolic compounds, carotenoid and flavonoids. The aim of this review is to provide basic information to build chilling-indicators and optimal nutrition management under adverse temperature conditions as broadly considering mineral uptake, carbohydrate metabolism and antioxidative defense system.

Infeasibility of Measuring $Ca^{2+}$ in Menadione-Exposed Platelets Using Fluorescent Dyes (메나디온에 의한 혈소판 내 칼슘 변화측정시 형광 색소 사용의 문제점)

  • Chung, Sun-Hwa;Lee, Moo-Yeol;Lee, Joo-Young;Chung, Seung-Min;Chung, Jin-Ho
    • YAKHAK HOEJI
    • /
    • v.41 no.6
    • /
    • pp.749-755
    • /
    • 1997
  • It has been reported that dose-dependent $Ca^{2+}$ increase by menadione in platelets could be measured by fluorescent dye, quin-2. The problems will be described here rel ating to measuring $Ca^{2+}$ in menadione-exposed platelets using fura-2 and fluo-3, widely used fluorescent indicators. Additions of menadione to fura-2 loaded platelets and their lysates resulted in marked reduction in fluorescence intensity at both 340nm ($Ca^{2+}$-unbound form) 380nm ($Ca^{2+}$-undbound form) excitation wavelengths. Fura-2 excitation spectra were overlapped with UV-visible absorption spectra of menadione, suggesting that light absorption by menadione itself could quench fluorescence generated by fura-2. Next approach was to use fluo-3 which has the higher wavelength (490nm) of excitation. Previous work demonstrated that treatment with probenecid to platelets was required to prevent fluo-3 dye leakage. However, probenecid itself was proven to be inadequate to measure the concentration of intracellular $Ca^{2+}$; by reducing menadione-induced cytotoxicity in platelets. Our results suggest that it is not feasible to measure $Ca^{2+}$ in platelets by using fura-2 and fluo-3 in the presence of probenecid, and cautions should be taken to measure changes of intracellular $Ca^{2+}$ levels by fluorescent dyes following chemical exposure.

  • PDF

Unplanned Reoperation Rate at a Government-Designated Regional Trauma Center in Gangwon Province

  • Kim, Minju;Kim, Seongyup
    • Journal of Trauma and Injury
    • /
    • v.34 no.1
    • /
    • pp.39-43
    • /
    • 2021
  • Purpose: Determining appropriate ways to assess health care quality within the National Health Insurance System is of interest to both the Korean government and the medical community. However, in the trauma field, the number of indicators used to evaluate surgical quality is limited. Using data collected over 5 years at Wonju Severance Christian Hospital Trauma Center in Korea, this study aimed to determine whether the unplanned reoperation rate in the field of trauma surgery could be used to assess the quality of an institution's surgical care. Methods: In total, 665 general surgical procedures were performed at the Trauma Center in 453 patients with abdominopelvic injuries from January 2015 to December 2019. Data were collected from the Trauma Center's data registry and medical records, and included information regarding patients' demographic characteristics, the type of index operation, and the reason for unplanned reoperations. Results: A total of 453 index operations were evaluated. The proportion of patients with an Injury Severity Score (ISS) >15 was 48-70% over the 5-year period, with an unplanned reoperation rate of 2.1-9.3%. Patients had an average ISS score of 17.5, while the average Abbreviated Injury Scale Score was 2.87. Unplanned reoperations were required in about 7% of patients. The most common complications requiring reoperation were recurrent bleeding (26.9%), wound problems (26.9%), intestinal infarction (15.4%), and anastomosis site leakage (7.7%). The procedures most frequently requiring unplanned reoperations were bowel surgery (segmental resection, primary repair, enterostomy, etc.) (24.5%) and preperitoneal pelvic packing (10.6%). Conclusions: The proportion of reoperations was confirmed to be affected by injury severity.

Evaluation of Exposure Indicators for Plants by Silicon Tetrachloride Release (사염화규소 누출사고지점 주변 식물에 대한 노출지표 평가)

  • Park, Jae-Seon;Kim, Jee-Young;Kim, Myeong-Ock;Park, Hyun-Woo;Chung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.288-292
    • /
    • 2017
  • BACKGROUND: Silicon tetrachloride reacts with moisture in the atmosphere to generate hydrogen chloride, which affects the environment. Since silicon tetrachloride and its by-products are dispersed in the atmosphere in a short time after the silicon tetrachloride release into the atmosphere, it is difficult to directly assess the extent of environmental impact. In the present study, the exposure test of silicon tetrachloride or hydrogen chloride was examined in order to establish the criterion of the range affected by the silicon tetrachloride release, and the actual crops in the area exposed to silicon tetrachloride leakage were analyzed. METHODS AND RESULTS: For the experiment of exposure to silicon tetrachloride or hydrogen chloride, the leaves of red-pepper and corn were used in glass sealed containers. In the actual accident area, 59 samples from 10 different kinds of crops were collected. The pretreatment of the sample was performed by freezing and grinding, and then extracted using distilled water. The pH and concentration of chloride ($Cl^-$) ion of the extracted solution were measured using pH meter and ion chromatograph, respectively. CONCLUSION: Exposure to silicon tetrachloride caused visible damage, increasing the concentration of chloride ion, and decreasing the pH as well as hydrochloric acid. In the actual crops of the affected area, the tendency was the same as the result of the laboratory test, and the range of influence could be estimated through the concentration of $Cl^-$ ion over 2,000 mg/kg, and the correlation evaluation between the concentration of $Cl^-$ and pH. Therefore, the concentration of $Cl^-$ ion and the correlation between $Cl^-$ and pH would be considered as the factors to estimate the influence range of silicon tetrachloride release.

Evaluation of effectiveness of Smart Water City in Korea - Smart Water City project in Paju City, Gyeonggi Province (한국 스마트워터시티의 효과성 평가 - 경기도 파주시 스마트워터시티 사업을 중심으로)

  • Lee, Yookyung;Lee, Seungho
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.spc1
    • /
    • pp.813-826
    • /
    • 2020
  • This study analyzes the effects of the Smart Water City (SWC) project that was introduced from 2014 to 2016 in Paju City, Gyeonggi Province, Korea, focusing on the achievement of the business goals. The SWC is referred to as a city that embraces a healthy water supply system based on Smart Water Management (SWM) that promotes the efficiency of water management by combining Information and Communication Technologies (ICTs) with water and sewerage facilities. In order to evaluate the effectiveness of the SWC project, this study deploys evaluation criteria corresponding to the project objectives, and analyzes the outputs before and after the project. The results show that the SWC has contributed to enhancing water supply services and the reliability and drinking rate of tap water. Specific improvement areas include the rise of average water flow rate and water leakage reduction, the diffusion of water quality monitoring system, and the reduction of floating particle concentration and turbidity in drainage pipes was achieved. These were possible because of specific implementation plans for clear goal setting and achievement and active services for citizens. The data related to water quantity and quality showed improved performance compared to before the introduction of SWMS, which is a positive effect. However, a quantitative analysis of the outputs has limitations in identifying other external factors that have led to the changes. In the future, guidelines for spreading SWC and more comprehensive and specific evaluation indicators for SWC should be prepared, and SWMS should be developed in consideration of the needs of users.

A Study on the Measurement Method of Personal Information Protection Investment Performance (개인정보보호투자의 성과측정방안에 관한 연구)

  • Kim, Young-Il;Lee, Jae-Hoon
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • Personal information protection has become one of the most impending business issues because leakage of personal information can cause tremendous financial losses and image degradation. Consequently, personal information protection initiatives have been recognized widely in business. To invigorate personal information protection investments, performance measurement method such as cost benefits analysis or qualitative analyses are needed, which have not been studied enough in the previous studies. This study proposes a performance measurement model which can include quantitative and qualitative analyses in the context of personal information protection investments. A comparative analysis has been performed on security investment and IT investment performance measurements, which leads to choose the WiBe method (developed by the German Interior Ministry), considering the privacy characteristics and the method's applicability. In particular, the quantitative effect measured how proactive threat assessment based on the way according to the nature of the businesses and organizations of privacy and possible investment decisions. This study proposes the 16 performance indicators, which turn out to be meaningful in terms of their materiality and feasibility by conducting focus group interviews of 25 experts on personal information protection.