• Title/Summary/Keyword: Leakage dose

검색결과 149건 처리시간 0.029초

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

6 MV X-선 빔을 사용하는 치료실에 설치되는 직접 차폐식 도어의 차폐 두께 계산식 (Calculation Formula for Shielding Thickness of Direct Shielded Door installed in Treatment Room using a 6 MV X-ray Beam)

  • 박철서;김종언;강은보
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.545-552
    • /
    • 2020
  • 이 연구의 목적은 NCRP 보고서 151과 IAEA 안전 보고서 시리즈 47 기반으로 직접차폐식 도어의 납 두께 계산식을 유도하는 데 있다. 직접차폐식 도어에서 선량률 계산식을 유도한 후, 이 식을 납 차폐 두께 계산식에 대입하여 도어에서 차폐 두께 계산식을 유도하였다. 유도된 직접차폐식 도어의 차폐 두께 계산식으로부터 계산된 납 차폐 두께는 NCRP 및 IAEA 2차 방벽 차폐 두께 계산 방법으로 산출된 두께보다 약 6% 낮았다. 이 결과는 NCRP 및 IAEA 2차 방벽 차폐 두께 계산 방법으로부터 두께 계산이 더 보수적이고 2차 빔 차폐에 잘 맞는다는 의미로 해석된다. 결론적으로, 이 연구에서 유도된 직접차폐식 도어의 납 차폐 두께 계산식은 도어의 차폐 설계에 유용하게 사용될 수 있을 것으로 사료된다.

Protective effects of an ethanol extract of Angelica keiskei against acetaminophen-induced hepatotoxicity in HepG2 and HepaRG cells

  • Choi, Yoon-Hee;Lee, Hyun Sook;Chung, Cha-Kwon;Kim, Eun Ji;Kang, Il-Jun
    • Nutrition Research and Practice
    • /
    • 제11권2호
    • /
    • pp.97-104
    • /
    • 2017
  • BACKGROUND/OBJECTIVE: Although Angelica keiskei (AK) has widely been utilized for the purpose of general health improvement among Asian, its functionality and mechanism of action. The aim of this study was to determine the protective effect of ethanol extract of AK (AK-Ex) on acute hepatotoxicity induced by acetaminophen (AAP) in HepG2 human hepatocellular liver carcinoma cells and HepaRG human hepatic progenitor cells. MATERIALS/METHODS: AK-Ex was prepared HepG2 and HepaRG cells were cultured with various concentrations and 30 mM AAP. The protective effects of AK-Ex against AAP-induced hepatotoxicity in HepG2 and HepaRG cells were evaluated using 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide, lactate dehydrogenase (LDH) assay, flow cytometry, and Western blotting. RESULTS: AK-Ex, when administered prior to AAP, increased cell growth and decreased leakage of LDH in a dose-dependent manner in HepG2 and HepaRG cells against AAP-induced hepatotoxicity. AK-Ex increased the level of Bcl-2 and decreased the levels of Bax, Bok and Bik decreased the permeability of the mitochondrial membrane in HepG2 cells intoxicated with AAP. AK-Ex decreased the cleavage of poly (ADP-ribose) polymerase (PARP) and the activation of caspase-9, -7, and -3. CONCLUSIONS: These results demonstrate that AK-Ex downregulates apoptosis via intrinsic and extrinsic pathways against AAP-induced hepatotoxicity. We suggest that AK could be a useful preventive agent against AAP-induced apoptosis in hepatocytes.

X-선 발생장치 시설의 방사선 차폐 해석 (Radiation Shielding Analysis for the X-ray Facility)

  • 권석근;최호신;문석형;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.34-39
    • /
    • 1987
  • X-선 발생장치 시설에 대한 방사선 차폐해석은 두가지 측면에서 고려된다. 먼저 1차 방사선과 누설방사선에 의한 영향을 고려하여야 하며 본 연구에서는 NCRP-49 및 51에 제시된 방법을 사용하였다. 둘째, 시설의 미로 출입구에서는 산란방사선에 의한 영향이 보다 중요한데, 본연구에서는 이 영향을 평가하기 위하여 Albedo 개념을 근거로 한 단순한 방법이 제시되었고, 이를 토대로 계산된 결과를 컴퓨터 코-드(MORSE-CG)의 계산치 및 실측된 결과와 비교하였다. 본 연구에서 제시된 방법에 의한 결과는 미로출입구 안쪽의 경우에 대한 해석에서는 약간의 오차를 보이고 있으나 미로출입구 문바깥에서는 비교적 잘 일치한다. 여기서 출입문바깥의 경우에 대한 해석이 방사선방어 측면에서 보다 중요하다는 관점에서 볼 때 이 방법은 의료용 또는 산업용의 X-선 및 감마선시설의 차폐설계 및 해석에 응용될 수 있을 것이라고 판단된다.

  • PDF

비파괴 검사 시스템의 융합 적용 사례 (The Convergence Application Example of Non-destructive Inspection System)

  • 이정익
    • 한국융합학회논문지
    • /
    • 제8권3호
    • /
    • pp.191-197
    • /
    • 2017
  • 본 개발은 중간 크기 미만의 외형 결함을 검출함에 있어 X-Ray 광원을 사용하는 비파괴 장비이다. 본 연구개발물의 차별성은 X-Ray광원을 이용 중소형 생산제품들의 외부결함 유무를 실시간 검사할 수 있으며 표면 방사선 누설선량에 있으면서 검사 속도제어가 가능하다. 이를 소프트웨어로 해결하였다. 또한 작업 중 작업자 안전을 위해 도어 차단이 가능하고 동시에 장비 내부 구동 영상의 획인이 가능하다는 점이다. 이런 원리로 현재는 중소형 부품에서부터 크게는 컨테이너와 같은 검사시스템의 기반 기술로 활용이 가능하다. 본 연구는 자동차 산업 외에 다른 다양한 비파괴 시장 산업에 큰 영향을 미칠 것이다. 마지막으로 개발된 비파괴 장비는 $0.2Sv{\mu}$ 하에서 제어된다는 사실은 아주 중요한 사실이다.

메나디온에 의한 혈소판 내 칼슘 변화측정시 형광 색소 사용의 문제점 (Infeasibility of Measuring $Ca^{2+}$ in Menadione-Exposed Platelets Using Fluorescent Dyes)

  • 정선화;이무열;이주영;정승민;정진호
    • 약학회지
    • /
    • 제41권6호
    • /
    • pp.749-755
    • /
    • 1997
  • It has been reported that dose-dependent $Ca^{2+}$ increase by menadione in platelets could be measured by fluorescent dye, quin-2. The problems will be described here rel ating to measuring $Ca^{2+}$ in menadione-exposed platelets using fura-2 and fluo-3, widely used fluorescent indicators. Additions of menadione to fura-2 loaded platelets and their lysates resulted in marked reduction in fluorescence intensity at both 340nm ($Ca^{2+}$-unbound form) 380nm ($Ca^{2+}$-undbound form) excitation wavelengths. Fura-2 excitation spectra were overlapped with UV-visible absorption spectra of menadione, suggesting that light absorption by menadione itself could quench fluorescence generated by fura-2. Next approach was to use fluo-3 which has the higher wavelength (490nm) of excitation. Previous work demonstrated that treatment with probenecid to platelets was required to prevent fluo-3 dye leakage. However, probenecid itself was proven to be inadequate to measure the concentration of intracellular $Ca^{2+}$; by reducing menadione-induced cytotoxicity in platelets. Our results suggest that it is not feasible to measure $Ca^{2+}$ in platelets by using fura-2 and fluo-3 in the presence of probenecid, and cautions should be taken to measure changes of intracellular $Ca^{2+}$ levels by fluorescent dyes following chemical exposure.

  • PDF

홀뮴 및 홀뮴-키토산 복합체가 정상 백서 뇌에 미치는 효과에 대한 연구 (Effects of 166Holmium and 166Holmium-chitosan Complex(166Ho-CHICO) on Normal Brain of Rats)

  • 손경화;조철우;안영환;박찬희;심철;박경배;조경기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권10호
    • /
    • pp.1309-1315
    • /
    • 2000
  • Objectives : We performed an in vivo experiment to investigate the effect of $^{166}Holmium$ and $^{166}Holmium$-chitosan complex($^{166}Ho$-CHICO) on the normal brain of rats and to determine the sublethal dose of $^{166}Ho$-CHICO. Materials and Methods : $^{166}Ho$ is a beta and gamma ray emitter. $^{166}Ho$-CHICO is a novel radio-pharmaceutical complex with chitosan to facilitate the transport of $^{166}Ho$ obtained from Korea Atomic Energy Research Center(Taejon, Korea). It is in acidic form and becomes gel state at alkaline pH. One hundred and seventy consecutive rats were divided into four groups : $^{166}Ho$ treated(n=50), $^{166}Ho$-CHICO treated(n=57), saline treated(n=5) and chitosan treated(n=5) groups. $^{166}Ho$ and $^{166}Ho$-CHICO were injected into the rat brain stereotactically with various doses of 0.1mCi/$20{\mu}l$, 0.2mCi/$20{\mu}l$, 0.3mCi/$20{\mu}l$, and 0.4mCi/$20{\mu}l$ using an automated microinjector. Nuclear imaging, histopathological and hematological studies were performed in 10 rats in each group at 1 day, 3days, 7 days, 1 month and 3 months after the injections. Results : An infiltration of inflammatory cells and necrotic changes were noted in $^{166}Ho$ treated group at 1 week after the injection. A wedge-shaped tissue defect due to necrosis, lined with infiltrated glial cells in $^{166}Ho$ treated group and a cystic defect lined with reactive astroglial cells in $^{166}Holmium$-CHICO treated group at 3 months after the injection were observed. $^{166}Ho$ alone without chitosan leaked out and caused necrotic lesion on the cerebral surface but $^{166}Holmium$-CHICO treated group did not show this feature. As the dose of $^{166}Ho$ increased, the mortality rates were also increased. The mortality rate of the $^{166}Holmium$-CHICO group was higher than the $^{166}Ho$ treated group at a dose of 0.4mCi/$20{\mu}l$/300g. There was no detectable radioactivity due to the leakage or extravasation from the injected site of the brain on the scintigraphy performed at 1 hour, 24 hours and 48 hours after the injection. There was also no detectable activity of $^{166}Holmium$-CHICO in other organs including spleen, liver and kidney. Conclusions : $^{166}Ho$-CHICO did not leak out to the critical cortical surface of the brain from the injection site and induced radiation changes of the parenchyma around the injection site without cortical damage. The sublethal dose of $^{166}Ho$-CHICO for the normal brain in rats was determined to be 0.2mCi/$20{\mu}l$/300g.

  • PDF

Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가 (Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking)

  • 김태원;유순미;전수동;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.73-81
    • /
    • 2018
  • 목 적 : 다발성 뇌 전이의 방사선치료 시 jaw tracking(JT)과 fixed jawFJ)를 이용한 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)를 비교하고 유용성을 평가하고자 한다. 대상 및 방법 : JT를 이용하여 치료받은 다발성 뇌 전이(Multiple Brain Metastasis) 환자 중 6개 이상의 종양이 있고 조사면 크기가 $14{\times}14cm^2$ 이상인 환자 10명을 대상으로 하였다. Eclipse(Ver 13.6 Varian, USA)로 JT와 FJ의 전산화치료계획을 각각 수립하였으며, 전자포털영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 감마지수(Gamma Index, 3 mm, 3 %, 95 % 신뢰구간) 및 최대선량차이(Max. Dose Difference)를 측정하였다. 또한 손상위험장기(Organ At Risk, OAR)의 $D_{max}$$D_{mean}$을 산출하고 비교하였으며 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity Index, HI)를 평가하였다. 결 과 : JT와 FJ의 측정값을 평가한 감마지수는 모든 Case에서 허용 기준(3 mm, 3 %, 95 % 신뢰구간)에 충족하였으며, 최대선량차이값은 Leaf End Transmission이 발생하는 영역에서 시계방향(Clockwise, CW)은 최대 98.4 %, 평균 43.6 %, 반시계방향(Counter-Clockwise, CCW)은 최대 67.9 %, 평균 41.0 %로 측정되었다. 손상위험장기는 JT를 사용하였을 때 각 정상장기에 대한 $D_{max}$의 최대값은 15.36 %~74.59 %, 평균값은 2.84 %~39.80 % 감소, $D_{mean}$의 최대값은 27.90 %~65.23 %, 평균값은 7.70 %~41.71 %로 감소하였으며, 처방선량지수와 선량균질지수값은 차이가 없었다. 결 론 : 다발성 뇌 전이에서 VMAT으로 치료할 경우 JT를 이용하면 치료계획용적(Planning Target Volume, PTV)의 선량분포에 영향을 미치지 않으면서 불특정 영역에서 발생하는 방사선의 누설 및 투과로 인한 불필요한 피폭을 감소시키고 정상장기에 더 낮은 선량으로 방사선치료가 가능할 것으로 사료된다.

  • PDF

사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰 (Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients)

  • 안승권;김용배;이익재;송태수;손동민;장영재;조정희;김주호;김동욱;조재호;서창옥
    • Radiation Oncology Journal
    • /
    • 제26권3호
    • /
    • pp.189-194
    • /
    • 2008
  • 목 적: 본 연구팀은 사지에 발병한 카포시육종의 방사선치료를 위하여, 물볼루스를 사용할 수 있는 기구를 고안하였고, 쌀볼루스 사용시와 비교하여 유용성을 평가하고자 하였다. 대상 및 방법: 환자가 앙와위 자세에서 하지를 삽입 할 수 있는 폴리스틸렌 상자를 만들고 비닐 재질의 진공비닐을 집어 넣어 물이 누수 되지 않도록 결합하였으며, 진공비닐안에 하지와 물 사이의 공기를 없애기 위해 진공 밸브와 진공 펌프를 연결하여 공기를 제거하였다. 본 연구에서 제작한 물기반 볼루스의 선량 균질도를 비교 평가하기 위해 진공비닐에 하지 팬텀을 삽입한 후 폴리스틸렌 상자에 직접 쌀을 채운 경우, 비닐봉지에 쌀을 담아서 넣은 경우, 그리고 물을 직접 채운 경우에 대해 전산화단층촬영을 시행하였다. 방사선치료계획시스템을 사용하여 공기층의 부피에 의한 밀도의 변화를 분석하였다. 또한 선형가속기를 사용하여 전산화단층 모의치료기와 동일한 셋업에서 하지 팬텀에 필름을 감고, 열형광선량계 6개를 조사야 안에 균등하게 붙여서, 대향이문 조사하여 선량의 균질도 및 선량 값을 측정하였다. 결 과: 각 세 종류 실험의 밀도 측정결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 14% 감소했으며, 쌀을 비닐 봉지에 나누어 넣은 경우는 18% 감소하였다. 필름의 분석 결과 물볼루스가 쌀볼루스보다 균질도가 $4{\sim}4.4%$ 정도 우수한 것으로 나타났다. 열형광선량계 측정 평균값 분석결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 3.4% 증가했으며, 쌀을 비닐봉지에 나누어 넣은 경우는 4.3% 증가하였다. 결 론: 자체 제작한 물볼루스 기구는 육안으로 치료 조사야를 확인할 수 있어 셋업의 정확성을 높였으며, 진공 밸브와 진공 펌프를 사용하여 공기층을 감소시켜 치료의 정확성을 높이는 동시에 목적 종양에 균질도가 높은 선량을 부여 할 수 있는 좋은 방안이라 할 수 있다.

The Treatment Outcome of Elderly Patients with Idiopathic Trigeminal Neuralgia : Micro-Vascular Decompression versus Gamma Knife Radiosurgery

  • Oh, In-Ho;Choi, Seok-Keun;Park, Bong-Jin;Kim, Tae-Sung;Rhee, Bong-Arm;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권4호
    • /
    • pp.199-204
    • /
    • 2008
  • Objective : This study was designed to compare the efficacy of micro-vascular decompression (MVD) and Gamma knife radiosurgery (GKRS) for elderly idiopathic trigeminal neuralgia patients by analyzing the clinical outcome. Methods : In the past 10 years, 27 elderly patients were treated with MVD while 18 patients were treated with GKRS (>65-years-old). We reviewed their clinical characteristics and clinical courses after treatment as well as the treatment outcomes. For patients who were treated with MVD, additional treatment methods such as rhizotomy were combined in some areas. In GKRS, we radiated the root entry zone (REZ) with the mean maximum dose of 77.8 (70-84.3) Gy and one 4 mm collimator. Results : The mean age was 68.1 years for MVD, and 71.1 years for GKS group. The average time interval between first presenting symptom and surgery was 84.1 (1-361) months, and 51.4 (1-120) months, respectively. The mean follow-up period after the surgery was 35.9 months for MVD, and 33.1 months for GKRS. According to Pain Intensity Scale, MVD group showed better prognosis with 17 (63%) cases in grade I-II versus 10 (55.6%) cases in GKRS group after the treatment. The pain recurrence rate during follow up did not show much difference with 3 (11.1%) in MVD, and 2 (11.1%) in GKRS. After the treatment, 2 cases of facial numbness, and 1 case each of herpes zoster, cerebrospinal fluid (CSF) leakage, hearing disturbance, and subdural hematoma occurred in MVD Group. In GKRS, there was 1 (5.6%) case of dysesthesia but was not permanent. Three cases were retreated by GKRS but the prognosis was not as good as when the surgery was used as primary treatment, with 1 case of grade I-II, and 1 case of recurrence. The maximal relieve of pain was seen just after surgery in MVD group, and 1 year after treatment in GKRS group. Conclusion : For trigeminal neuralgia patients with advanced age, MVD showed advantages in immediately relieving the pain. However, in overall, GKRS was preferable, despite the delayed pain relief, due to the lower rate of surgical complications that arise owing to the old age.