• 제목/요약/키워드: Leakage accident

검색결과 268건 처리시간 0.026초

원전 내 배관의 증기 누설 사고 시 누설 탐지 포집/이송 시스템 예비 해석 (Preliminary Analysis of a Sampling and Transportation System for Leak Detection during Steam Leak Accident of a Pipe in Nuclear Power Plants)

  • 최대경;최청열;권태순;어동진
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.25-34
    • /
    • 2020
  • As leakage in nuclear power plants could cause a variety of problems, it is very critical to monitor leakage from the safety point of view. Accordingly, a new type of leak detection system is currently being developed and flow characteristics of the sampling and transportation system are investigated by using numerical analysis as a part of the development process in this study. The results showed that the steam mass fraction varied according to the effect of the gap between the insulation and piping component, transportation velocity, and material properties of porous media during the sampling and transportation process. The results of this study should be useful for understanding flow characteristics of the sampling and transportation system and its design and application.

항만에서의 위험·유해물질(HNS) 누출사고 대응에 관한 연구 (A Study of Emergency Response for the Leakage Accident of Hazardous and Noxious Substances in a Port)

  • 우영진;이창준
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.32-38
    • /
    • 2016
  • In general, lots of containers including various dangerous materials are transported to the port located in big cities such as Busan where massive residents live. Thus, it's really important how to make the emergency response for the leak accidents of dangerous materials and evaluate the direct or indirect damages to adjacent areas. In this study, in order to make reasonable emergency plans, CA (Consequence Analysis) is employed after selecting a key hazardous and noxious material, hydrogen fluroide. This material accounts for the third largest portion of cargo volume among all dangerous materials and can cause a huge damage in case of leakages. As a case study, Busan North port is selected as a test port since the portion of dangerous materials is higher than that of other ports in Busan. It is assumed that 1 ton of hydrogen fluoride is spilled at Busan North port. CA is performed to assess the impact of this accident. Throughout CA, the ERPG-2 range of a leak accident can be evaluated and this result can be used for decision making tools for mitigating the impact of a leak accident. To mitigate the damage of this accident, suitable a protective equipment and resident evacuation procedures should be prepared. Finally, this study can provide a systematic approach to make the emergency plan for reducing economical and personal losses.

건축물내 일산화탄소 경보기 설치에 관한 연구 (A Study on Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석;오정석
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2008년도 춘계학술 발표회
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석 (Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler)

  • 강승규;최경석;윤준용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치 (New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents)

  • 길경석;한주섭;송재영;조한구;한문섭
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

화학물질 운송 화학사고의 통계 특성 분석에 관한 연구 (Statistical Analysis of Chemical Substance Transporting Accidents)

  • 이태형;이상재;신창현
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.23-30
    • /
    • 2016
  • 본 연구는 화학물질 운송 화학사고를 대상으로 각 연도별 사고현황, 사고유형, 사고원인 등의 화학사고 특성을 분석하였다. 그 결과 77건의 운송 화학사고 중 74건이 유 누출 유형에 의한 사고였으며, 사고 원인으로는 41건이 교통사고에 의한 화학사고였다. 또한, 사고다발 화학물질 조사에서는 46건의 사고가 유해화학물질에 의한 사고인 것으로 조사되었다. 화학물질 운송 화학사고의 예방 및 대응을 위해서는 화학물질 유 누출과 화학물질의 운송 교통사고에 의한 화학사고에 대한 예방책의 보완이 필요하며, 운송 화학사고가 발생되었을 경우 방재가 시스템적으로 신속히 이루어질 수 있도록 범국가적이고 체계적인 화학물질 운송안전 시스템을 구축하여 화학물질 운송에 적용하는 것이 필요하다.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

도로터널 내 수소차 누출시나리오에 따른 가연영역에 대한 위험성분석 연구 (Risk analysis of flammable range according to hydrogen vehicle leakage scenario in road tunnel)

  • 이후영;류지오
    • 한국터널지하공간학회 논문집
    • /
    • 제24권4호
    • /
    • pp.305-316
    • /
    • 2022
  • 화석연료의 고갈과 환경문제의 대안으로 수소에너지가 부각되고 있으며, 자동차 산업에서도 수소차의 보급이 증가하고 있다. 그러나 수소는 가연농도 범위가 4~75%로 넓은 가연영역을 가지고 있어 수소차 사고 시 안전에 대한 우려가 높은 실정이다. 특히, 터널이나 지하주차장과 같은 반밀폐 공간에서는 수소누출에 따른 화재나 폭발이 대형사고를 유발할 가능성이 높기 때문에 수소누출에 따른 가연영역 분석을 통해 수소 안전성에 대한 검토가 필요한 실정이다. 이에 본 연구에서는 표준단면의 도로터널에서 수소차량의 수소 누출조건과 터널 내 풍속에 따른 수소농도 해석을 수행하여 터널 내 풍속이 가연영역에 미치는 영향을 검토하였다. 수소의 누출조건은 1개의 탱크와 3개의 탱크가 통시에 TPRD를 통해 누출되는 조건과 대형크랙이 발생하여 누출하는 조건으로 하였으며, 터널 내 풍속은 0, 1, 2.5, 4.0 m/s를 고려하였다. 가연영역에 대한 검토결과, 1 m/s 이상의 풍속이 존재하는 경우에는 풍속이 없는 경우와 비교하여 최대 25%수준까지 감소하는 것으로 나타나고 있으며, 풍속증가에 따른 가연영역의 감소효과는 거의 없는 것으로 나타나고 있다. 특히 대형크랙이 발생하여 약 2.5초 만에 완전히 누출되는 경우에는 풍속이 증가하면 가연영역이 약간 증가하는 것으로 나타나고 있다. 또한 하향 분출되는 경우에 풍속이 작은 차량하부 영역에 수소가스가 상당히 긴 시간동안 잔류하는 것으로 분석되었다.

중수로 냉각재 펌프용 미케니컬 페이스 실의 성능 해석 (Performance Analysis of Mechanical Face Seal Used for Primary Heat Transport Pump in Heavy Water Reactor)

  • 김정훈;김동욱;김경웅
    • Tribology and Lubricants
    • /
    • 제27권5호
    • /
    • pp.240-248
    • /
    • 2011
  • Mechanical face seal installed in primary heat transport pump used for heavy water reactor prevents leakage of working fluid using thin working fluid film between primary seal ring and mating ring. If the leakage of working fluid exceeds the allowable volume, serious accident can be happened by the trouble of primary heat transport pump. The thinner fluid film exists between primary seal ring and mating ring, the less working fluid leaks out. On the other hand, if the thickness of fluid film is not enough, the life of mechanical face seal will be reduced by friction and wear. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the performance of mechanical face seals which have same deep straight groove and 11 different net coning values. As results, equilibrium clearance between primary seal ring and mating ring, leakage volume of working fluid, friction torque on sealing surface and stiffness of working fluid film were obtained. With increasing net coning value, equilibrium clearance and leakage volume increase, and friction torque and stiffness of fluid film decrease.