• Title/Summary/Keyword: Leakage Reduction

Search Result 483, Processing Time 0.029 seconds

Optimum Hydraulic Oil Viscosity Based on Slipper Model Simulation for Swashplate Axial Piston Pumps/Motors

  • Kazama, Toshiharu
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.84-90
    • /
    • 2021
  • Viscosity of hydraulic oils decreases due to loss reduction and efficiency increase of fluid power systems. However, low viscosity is not always appropriate due to the induction of large leakage and small lubricity. Therefore, a detailed study on the optimum viscosity of hydraulic oils is necessary. In this study, based on the thermohydrodynamic lubrication theory, numerical simulation was conducted using the slipper model of swashplate-type axial piston pumps and motors. The viscosity grades' (VG) effects of oils on power losses are mainly discussed numerically in fluid film lubrication, including changes in temperature and viscosity. The simulation results reveal that the flow rate increases and the friction torque decreases as VG decreases. The film temperature and power loss were minimised for a specific oil with a VG. The minimum conditions regarding the temperature and loss were different and closed. Under various operating conditions, the film temperature and power loss were minimised, suggesting that an optimum hydraulic oil with a specific VG could be selected for given operating conditions of pressure and speed. Otherwise, a preferable operating condition must be established to determine a specific VG oil.

Key parameters of toroidal HTS coil for a superconducting magnetic energy storage system

  • Miyeon, Yoon;Jinwoo, Han;Ji-Kwang, Lee;Kyeongdal, Choi;Jung Tae, Lee;Seungyong, Hahn;Woo-Seok, Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.50-54
    • /
    • 2022
  • High temperature superconducting (HTS) magnets for large-capacity energy storage system need to be composed of toroid magnets with high energy density, low leakage magnetic fields, and easy installation. To realize such a large capacity of a toroid HTS magnet, an HTS cable with large current capacity would be preferred because of the limited DC link voltage and instantaneous high power required for compensation of the disturbance in the power grid. In this paper, the optimal operating strategies of the SMES for peak load reduction of the microgrid system were calculated according to the load variation characteristics, and the effect of compensation of the frequency change in microgrid with a SMES were also simulated. Based on the result of the simulation, key design parameters of SMES coil were presented for two cases to define the specification of the HTS cable with large current capacities for winding of HTS toroid coils, which will be need for development of the HTS cable as a future work.

Water Distribution Network Partitioning Based on Community Detection Algorithm and Multiple-Criteria Decision Analysis

  • Bui, Xuan-Khoa;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.115-115
    • /
    • 2020
  • Water network partitioning (WNP) is an initiative technique to divide the original water distribution network (WDN) into several sub-networks with only sparse connections between them called, District Metered Areas (DMAs). Operating and managing (O&M) WDN through DMAs is bringing many advantages, such as quantification and detection of water leakage, uniform pressure management, isolation from chemical contamination. The research of WNP recently has been highlighted by applying different methods for dividing a network into a specified number of DMAs. However, it is an open question on how to determine the optimal number of DMAs for a given network. In this study, we present a method to divide an original WDN into DMAs (called Clustering) based on community structure algorithm for auto-creation of suitable DMAs. To that aim, many hydraulic properties are taken into consideration to form the appropriate DMAs, in which each DMA is controlled as uniform as possible in terms of pressure, elevation, and water demand. In a second phase, called Sectorization, the flow meters and control valves are optimally placed to divide the DMAs, while minimizing the pressure reduction. To comprehensively evaluate the WNP performance and determine optimal number of DMAs for given WDN, we apply the framework of multiple-criteria decision analysis. The proposed method is demonstrated using a real-life benchmark network and obtained permissible results. The approach is a decision-support scheme for water utilities to make optimal decisions when designing the DMAs of their WDNs.

  • PDF

Analysis on Shapes of Shear Pocket for the Full-Depth Precast Slab (프리캐스트 바닥판의 전단포켓 형상에 관한 해석 연구)

  • Han, Sang Yun;Lee, Man Seop;Lee, Seung Rok;Kang, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.817-822
    • /
    • 2006
  • Post-tensioning the full-depth precast slab longitudinally is to eliminate the tensile stresses in the transverse joints and to prevent any leakage through the joints. When the prestressing is applied to full-depth precast slab which does not composite steel girder, stress concentration occurs at the corners of shear pocket, and compressive stress is not uniformly distributed in the section of precast slab. In this paper, full-depth precast slabs using four different shapes of shear pockets are analyzed by commercial finite element program. Round type of shear pockets is superior to reduction in stress concentration.

Analysis of the effect of leakage on water head reduction in the pilot scale pipeline connected to the field pipeline. (현장 관망과 연결된 Pilot 스케일 관로에서 누수가 수두감쇠에 미치는 영향 분석)

  • Lee, Jeongseop;Ko, Dongwon;Lee, Taekwan;Yun, Seokjun;Choi, Dooyong;Kim, Sanghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.400-400
    • /
    • 2022
  • 관로 내 빈번히 발생하는 수격압의 발생은 관망 구조물에 피로가 누적되고 관벽에 손상을 발생시켜, 관로 내 누수가 다양한 형태로 생성된다. 관 내 누수가 발생되는 경우 관 내부의 수격압의 발생 시 생성되는 부압으로 인하여 외부 물질이 관으로 흡수되거나 혼합되어 스케일과 미생물의 생성되는 등 관 내의 수질에 악영향을 끼치며 마찰을 증가시켜 통수능이 감소하고 관리에 추가적인 비용을 발생시킨다. 이러한 영향을 방지하기 위해 관 내에서 생성되는 누수를 탐지하기 위하여 수격압을 발생시켜 압력파를 분석하거나 추적을 수행하는 여러 가지 연구들이 수행되었다. 본 연구에서는 현장 관망과 연결된 100A 대구경 관로에 관로 수압 발생장치를 연결하여 기존의 수격압을 발생시켜 분석하는 방법 대신 안전하고 용이한 방법인 압력파를 주입하여 실험을 수행하였다. 실험을 통해 획득한 데이터를 시간상에서 분석하고 Fourier 변환을 통한 빈도상 분석과 Wavelet 분석으로 신호주기에서 누수가 미치는 영향을 파악하였다. 실험 결과에서는 누수에 의한 영향으로 반사파가 직접적으로 변형되는 형태보다 시스템 전체에서 반영되어 수두가 감쇠되는 형태로 나타났다. Fourier 변환을 통해 무누수 조건과 누수조건의 비교에서 누수의 유무에 따른 신호의 형태가 차이를 보였다. 앞선 연구들에서의 누수의 특정한 위치를 찾아내는 형태 대신 신호처리 후 분석을 통해 시스템 전체에서 일어나는 감쇠를 통해 누수 존재 유무를 판별하고자 한다.

  • PDF

Concrete Specification and Mixing Design for the Reduction of Slab Defects in Underground Parking Lot (지하주차장 슬래브 하자 저감을 위한 콘크리트 규격 및 배합설계)

  • Kim, Han-Sic;Ha, Jung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.235-236
    • /
    • 2023
  • Concrete surfaces have weak surface strength due to bleeding and laitance, and problems such as peeling, cracking, and cracking may occur. In particular, underground parking lots can be said to be more vulnerable to peeling, breaking, and cracking if excessive loading of materials and equipment movement are not managed at the initial age after placing of concrete. Cracks, peeling, and cracking problems in slab concrete in underground parking lots of apartments can lead to leakage problems and affect finishing materials constructed on top of topping concrete, reducing the performance required for waterproof materials. Therefore, in this study, the bleeding and surface strength according to the standard of topping concrete and the use of admixture were reviewed to solve the crack, peeling, and cracking problems among the types of defects in underground parking lot slab concrete. As a result, it was derived that the optimal concrete compressive strength is 30MPa or more, and it is a reasonable performance design method to prohibit the substitution of admixtures.

  • PDF

Swelling and hydraulic characteristics of two grade bentonites under varying conditions for low-level radioactive waste repository design

  • Chih-Chung Chung;Guo-Liang Ren;I-Ting Chen;Che-Ju, Cuo;Hao-Chun Chang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1385-1397
    • /
    • 2024
  • Bentonite is a recommended material for the multiple barriers in the final disposal of low-level radioactive waste (LLW) to prevent groundwater intrusion and nuclear species migration. However, after drying-wetting cycling during the repository construction stage and ion exchange with the concrete barrier in the long-term repository, the bentonite mechanical behaviors, including swelling capacity and hydraulic conductivity, would be further influenced by the groundwater intrusion, resulting in radioactive leakage. To comprehensively examine the factors on the mechanical characteristics of bentonite, this study presented scenarios involving MX-80 and KV-1 bentonites subjected to drying-wetting cycling and accelerated ion migration. The experiments subsequently measured free swelling, swelling pressure, and hydraulic conductivity of bentonites with intrusions of seawater, high pH, and low pH solutions. The results indicated that the solutions caused a reduction in swelling volume and pressure, and an increase in hydraulic conductivity. Specifically, the swelling capability of bentonite with drying-wetting cycling in the seawater decreased significantly by 60%, while hydraulic conductivity increased by more than three times. Therefore, the study suggested minimizing drying-wetting cycling and preventing seawater intrusion, ensuring a long service life of the multiple barriers in the LLW repository.

Endoscopic ultrasound-guided intervention for inaccessible papilla in advanced malignant hilar biliary obstruction

  • Partha Pal;Sundeep Lakhtakia
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.143-154
    • /
    • 2023
  • Advanced malignant hilar biliary obstruction (MHBO) with inaccessible papilla poses a significant challenge to endoscopists, as drainage of multiple liver segments may be warranted. Transpapillary drainage may not be feasible in patients with surgically altered anatomy, duodenal stenosis, prior duodenal self-expanding metal stent, and after initial transpapillary drainage, but require re-intervention for draining separated liver segments. Endoscopic ultrasound-guided biliary drainage (EUS-BD) and percutaneous trans-hepatic biliary drainage are the feasible options in this scenario. The major advantages of EUS-BD over percutaneous trans-hepatic biliary drainage include a reduction in patient discomfort and internal drainage away from the tumor, thus reducing the possibility of tissue or tumor ingrowth. With innovations, EUS-BD is helpful not only for bilateral communicating MHBO but also for non-communicating systems with bridging hilar stents or isolated right intra-hepatic duct drainage by hepatico-duodenostomy. EUS-guided multi-stent drainage with specially designed cannulas and guidewires has become a reality. A combined approach with endoscopic retrograde cholangiopancreatography for re-intervention, interventional radiology, and intraductal tumor ablative therapies has been reported. Stent migration and bile leakage can be minimized with proper stent selection and technique, and stent blocks can be managed with EUS-guided interventions in a majority of cases. Future comparative studies are required to establish the role of EUS-guided interventions in MHBO as rescue or primary therapy.

Fisetin-Mediated Perturbations of Membrane Permeability and Intracellular pH in Candida albicans

  • Younhee Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.34 no.4
    • /
    • pp.783-794
    • /
    • 2024
  • The antifungal activity of fisetin against Candida albicans is explored, elucidating a mechanism centered on membrane permeabilization and ensuing disruption of pH homeostasis. The Minimum Inhibitory Concentration (MIC) of fisetin, indicative of its interaction with the fungal membrane, increases in the presence of ergosterol. Hoechst 33342 and propidium-iodide staining reveal substantial propidium-iodide accumulation in fisetin-treated C. albicans cells at their MIC, with crystal violet uptake assays confirming fisetin-induced membrane permeabilization. Leakage analysis demonstrates a significant release of DNA and proteins in fisetin-treated cells compared to controls, underscoring the antifungal effect through membrane disruption. Green fluorescence, evident in both the cytoplasm and vacuoles of fisetin-treated cells under BCECF, AM staining, stands in contrast to controls where only acidic vacuoles exhibit staining. Ratiometric pH measurements using BCECF, AM reveal a noteworthy reduction in intracellular pH in fisetin-treated cells, emphasizing its impact on pH homeostasis. DiBAC4(3) uptake assays demonstrate membrane hyperpolarization in fisetintreated cells, suggesting potential disruptions in ion flux and cellular homeostasis. These results provide comprehensive insights into the antifungal mechanisms of fisetin, positioning it as a promising therapeutic agent against Candida infections.

Enzymatic Hydrolysis of Yellowfin Sole Skin Gelatin in a Continuous Hollow Fiber Membrane Reactor (연속식 중공사막 반응기를 이용한 각시가자미피 젤라틴의 가수분해)

  • KIM Se-Kwon;BYUN Hee-Guk;KANG Tae-Jung;SONG Dae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.2
    • /
    • pp.120-132
    • /
    • 1993
  • A continuous hollow fiber membrane reactor(CHFMR) was developed and optimized for the production of yellowfin sole(Limanda aspera) skin gelatin hydrolysates using trypsin. The results were summerized as follows: The $K_m$ value of the CHFMR was 2.4 times higher than that of the batch reactor, indicating reduced enzyme affinity for the substrate. The $K_2$ value of the CHFMR was 8.5 times lower than that of the batch process, showing a significant reduction in trypsin activity in the CHFMR. The optimum operating conditions for the CHFMR process were $55^{\circ}C$, pH 9.0, flux 7.79 ml/min, residence time 77min, and trypsin to substrate ratio, 0.01(w/w) After operating for 60min under the above conditions, $79\%$ of the total amount of initial gelatin was hydrolysed. Enzyme leakage was observed through the 10,000 MWCO membrane after the 20min of reactor operation, while none occurred after 5hr. Total enzyme leakage was about $12.95\%$ at $55^{\circ}C$ for 5hrs. However, there was no apparent correlation between enzyme leakage and substrate hydrolysis. The membrane has a significant effect on trypsin activity loss for 60min of the CHFMR operation. The CHFMR operating with the membrane lost $34\%$ of the initial activity versus a $23\%$ loss of activity after 3hr in the continuous reactor lacking the hollow fiber membrane. The measurement of fouling property showed that relative flux reduction was $91\%$ and flux recover rate was $92\%$ at $10\%$ substrate solution. The productivity(378.85mg product/mg enzyme) of the CHFMR was more than 4 times higher than that of the batch reactor at $55^{\circ}C$.

  • PDF