• Title/Summary/Keyword: Leakage Prevention System

Search Result 123, Processing Time 0.025 seconds

Case Analysis of the Harmful Chemical Substances' Spill (유해화학물질 유출의 사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.90-98
    • /
    • 2014
  • Lately accidents of harmful chemical substance in korea were repeatedly replaying. We studied problems and preparation plan in 2008 years~2014 years through analysis cases of harmful chemical substance. Leakage of chemical substance's accident situation shows that leakage in the workplace is the most 10 cases, accounting for 58.6% is the largest proportion in 2009. Leakage according to explosion accounting for 50% (5 cases) in 2004, 25% (4 cases) in 2007 and 33.3% (4 cases) in 2011 has very irregular change. Therefore, A major cause of accidents is lack of safety management. Harmful chemical substance showed various aspects, high residual substance and non-visible characteristic so response and recovery was easy. And the second damage to move a distance causes environment pollution. So a mutual-assistance system and integrated system of related organization have to build and expert of chemical incident response and therapist of chemical substance response have to establish to do efficient and rapid response.

해안매립지에서의 추적자시험 및 수위변화특성 연구

  • 이진용;황대규;이명재;최예권;김정우;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.221-224
    • /
    • 2002
  • To demonstrate prevention of the leachate leakage out of the landfill with creating inward hydraulic gradient, a tracer test and continuous waterlevel monitoring at the Inside and outside of the barrier wall of a costal landfill were peformed. When the tracers were injected into the well outside of the vertical wall system with high water level, then they were detected at the well inside of the system with low water level. Furthermore the lowered water level at the inside of the landfill than that at the outside prevented leachate leakage out of the landfill. This study reports results of the tracer test and waterlevel monitoring.

  • PDF

Prevention of Oil Contamination in the Excitation System of a Power Plant Generator (발전용 발전기 여자설비의 오일 오염방지)

  • Choi, Jae-Gyu;Yoo, Ho-Seon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.7 no.2
    • /
    • pp.30-38
    • /
    • 2011
  • The purpose of this paper is to review the understanding of pollution causes in the excitation system and how to solve the problem. The cause of the problem was in-leakage of bearing lubricant oil through the gap between rotor and outer in the air deflector, which was triggered by a negative pressure with respect to the operation of a collector ring fan in the collector house. In order to prevent exciting current transmission equipment pollutant, the reduction of the negative gage pressure of the inside of collector house is required. The protection in-leakage of bearing lubricant oil through the gap between rotor and outer of the air deflector are necessary. The reduction of the inside diameter of air deflector and the expansion of inlet filter of collector house are inevitable.

  • PDF

Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements (공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구)

  • Han, Yoon-Jung;Oh, Kyu-Hwan;Kim, Su-Ryon;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.379-387
    • /
    • 2016
  • In this study, a survey was conducted on the required measurement and waterproofing performance for residential building underground structure leakage prevention system. According to the results of the survey, it has been determined that leakage problem is considered to be quite severe, and many respondents have agreed. The legal guidelines and regulation systems do not reflect properly on the environmental requirements or conditions, resulting in continued leakage problem. In regards to this, a standardized waterproofing technique that can be used in underground areas of residential structures is required as an obligation and the development of high performance waterproofing method that allows for wet concrete surface adhesion and a guideline, design and maintenance method that allows the control of overall situational control of leakage is required.

A Study on Insider Behavior Scoring System to Prevent Data Leaks

  • Lim, Young-Hwan;Hong, Jun-Suk;Kook, Kwang Ho;Park, Won-Hyung
    • Convergence Security Journal
    • /
    • v.15 no.5
    • /
    • pp.77-86
    • /
    • 2015
  • The organization shall minimize business risks associated with customer information leaks. Enhance information security activities through voluntary pre-check and must find a way to detect the personal information leakage caused by carelessness and neglect accident. Recently, many companies have introduced an information leakage prevention solution. However, there is a possibility of internal data leakage by the internal user who has permission to access the data. By this thread it is necessary to have the environment to analyze the habit and activity of the internal user. In this study, we use the SFI analytical technique that applies RFM model to evaluate the insider activity levels were carried out case studies is applied to the actual business.

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

Development of the Automobile Part for the Engine Oil Leakage Prevention by the Precise Cold Forging (정밀냉간단조에 의한 엔진오일 누수방지용 자동차부품 개발)

  • Kwon H. B.;Lee B. K.
    • Transactions of Materials Processing
    • /
    • v.14 no.8 s.80
    • /
    • pp.675-680
    • /
    • 2005
  • This study was aimed at the design of the dies for the automobile part for the engine oil leakage prevention using the computer simulation to shorten the period of production, on the basis of the process planning which was designed by the field experts. In the computer simulation,'eesy-2-form' of 2D FEM simulation package and 'eesy-DieOpt' have been used, which are the commercial process analysis and die design program. Through the simulation of 'eesy-2-form', we could know the propriety of the forming process, the inner pressure of the die and the suitable fitting pressure between the insert and the sleeve which was not showing any positive tangential stresses in the insert. Through the simulation of 'eesy-DieOpt', we could know the number of the stress ring, the diameter ratios, the stresses of the die, the shrink fitting tolerance and temperature in the condition of the already determined maximum outer die diameter of the multi-stage former. The validity of the die design using the computer simulation was analyzed by the experiments and the results were satisfactory. As the results of this study, the new and easy die design system for cold forging has been developed.

The 3-D Simulation of Electrophoresis Method in Leachate System for Repairing of Leaks in Waste Landfill Geomembrane Liner (폐기물 매립지 차수층 누출시 전기영동 복원을 위한 침출수 환경에서의 3차원 형상 모사 연구)

  • Han, Sang-Jae;Kim, Jong-Yun;Kim, Byung-Il;Kim, Soo-Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.17-25
    • /
    • 2010
  • Electrophoresis may offer a new technique to repair in service leaking geomembrane liner of municipal solid waste (MSW) impoundment. The method involves introducing a suspended clay particles, which are charged negatively, into the leakage in geomembrane liners by electrokinetic phenomena and formation of clay cake around leakage for prevention of leachate outflows. Therefore, the 3-dimensional leakage simulation experiments are conducted to evaluate the field applicability of sealing leaks of waste impoundment. In addition, the adequateness of optimum influence factors deduced from 1-dimensional experiments is evaluated. After the test, the total size (width, length) of clay cake formation around leak is increased with enlargement of leakage diameter and distance decrease detween anode and cathode.

UTrustDisk: An Efficient Data Protection Scheme for Building Trusted USB Flash Disk

  • Cheng, Yong;Ma, Jun;Ren, Jiangchun;Mei, Songzhu;Wang, Zhiying
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.2276-2291
    • /
    • 2017
  • Data protection of removable storage devices is an important issue in information security. Unfortunately, most existing data protection mechanisms are aimed at protecting computer platform which is not suitable for ultra-low-power devices. To protect the flash disk appropriately and efficiently, we propose a trust based USB flash disk, named UTrustDisk. The data protection technologies in UTrustDisk include data authentication protocol, data confidentiality protection and data leakage prevention. Usually, the data integrity protection scheme is the bottleneck in the whole system and we accelerate it by WH universal hash function and speculative caching. The speculative caching will cache the potential hot chunks for reducing the memory bandwidth pollution. We adopt the symmetric encryption algorithm to protect data confidentiality. Before mounting the UTrustDisk, we will run a trusted virtual domain based lightweight virtual machine for preventing information leakage. Besides, we prove formally that UTrustDisk can prevent sensitive data from leaking out. Experimental results show that our scheme's average writing throughput is 44.8% higher than that of NH scheme, and 316% higher than that of SHA-1 scheme. And the success rate of speculative caching mechanism is up to 94.5% since the access pattern is usually sequential.

Research on User Data Leakage Prevention through Memory Initialization (메모리 초기화를 이용한 사용자 데이터 유출 방지에 관한 연구)

  • Yang, Dae-Yeop;Chung, Man-Hyun;Cho, Jae-Ik;Shon, Tae-Shik;Moon, Jong-Sub
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.71-79
    • /
    • 2012
  • As advances in computer technology, dissemination of smartphones and tablet PCs has increased and digital media has become easily accessible. The performance of computer hardware is improved and the form of hardware is changed, but basically the change in mechanism was not occurred. Typically, the data used in the program is resident in memory during the operation because of the operating system efficiency. So, these data in memory is accessible through the memory dumps or real-time memory analysis. The user's personal information or confidential data may be leaked by exploiting data; thus, the countermeasures should be provided. In this paper, we proposed the method that minimizes user's data leakage through finding the physical memory address of the process using virtual memory address, and initializing memory data of the process.