• 제목/요약/키워드: Leakage Magnetic Flux Method

검색결과 90건 처리시간 0.025초

누설자속법을 이용한 배관내부 부식 평가 (Corrosion Assessment of In-pipe using Magnetic Flux Leakage Technique)

  • 이원용;이병주;양성일;김영주;안봉영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.402-402
    • /
    • 2000
  • MFL(Magnetic Flux Leakage) methods are used extensively for inspection of ferromagnetic materials. As an example, pipelines that are buried underground are inspected using MFL methods. By the MFL methods, ferromagnetic pipelines are magnetized by a permanent magnet or an electromagnet and then flux leakage is detected at the defection position. In this paper, we perform modeling of the magnetized pipelines. Also we propose the method localization of th defected areas. The effectiveness of the proposed method is verified experimentally.

  • PDF

침수에 의한 누전지역의 자속밀도 영향 (Influence of Flux Density of Electric Leakage Area by Inundation)

  • 최운식;김탁용;김진사
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1109-1113
    • /
    • 2010
  • Recently, important for the safety has been increasing together economic developments. The leakage only is measured by the voltage difference. This method is a way to contact the electric leakage area. It can cause electric shock at users. We propose a non-contact method to detect a short circuit in this paper. We investigate magnetic field at electric leakage area to present non-contact method. Simulated environment created a short circuit in the flooded areas. Voltage is supplied 50, 150 and 200[V]. Magnetic field was measured at 0, 5 and 10[cm]. Magnetic flux was reduced about $0.4[{\mu}T/cm]$ depending on the distance changes in the steady region. But we confirmed that magnetic flux is measured the same value depending on the distance changes in the electric leakage area.

배관용 자기누설 비파괴 검사에서 축방향 미소결함의 형상 판정에 관한 연구 (A Study on Determining the Shape of Small Axial Cracks by using Magnetic Flux Leakage in NDT System for Underground Pipe)

  • 김희민;박관수
    • 한국자기학회지
    • /
    • 제23권1호
    • /
    • pp.18-25
    • /
    • 2013
  • 배관용 비파괴 검사에서 자기누설방식을 이용하여 배관의 결함을 검출하도록 개발된 탐상 시스템 장비를 MFL PIG(Magnetic Flux Leakage Pipeline Inspection Gauge)라 한다. 이 장비는 투자율이 큰 금속 배관의 길이 방향인 축방향으로 자기장을 형성하고, 결함이 있는 부분에 발생하는 누설 자속 신호를 홀센서를 이용하여 검출한다. 하지만 MFL PIG는 배관에 축방향으로 발생한 미소결함에 대해서는 누설 자속의 발생량이 미세하여 결함 유무를 판별하기 어렵다. 본 논문에서는 배관에 발생한 축방향 미소결함을 검출하기위해 CMFL(Circumferential MFL) PIG를 적용하였고, 결함 주위에 발생한 누설 자속 신호의 크기 및 분포를 3차원 정자계 유한요소법을 이용하여 검출 및 분석하였다. 이러한 검출 신호로부터 길이, 폭, 깊이와 같은 결함의 형상을 판정하는 기법을 제안하였고 이를 CMFL PIG 모의 성능 실험을 통하여 비교 및 검증하였다.

비접촉식 정밀 변위 측정용 자기센서 모델링 (Modeling of a Non-contact Type Precision Magnetic Displacement Sensor)

  • 신우철;홍준희;이기석
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.42-49
    • /
    • 2005
  • Our purpose is to develop a precision magnetic displacement sensor that has sub-micron resolution and small size probe. To achieve this, we first have tried to establish mathematical models of a magnetic sensor in this paper. The inductance model that presents basic measuring principle of a magnetic sensor is based on equivalent magnetic circuit method. Especially we have concentrated on modeling of magnetic flux leakage and magnetic flux fringing. The induced model is verified by experimental results. The model, including the magnetic flux leakage and flux fringing effects, is in good agreement with the experimental data. Subsequently, based on the augmented model, we will design magnetic sensor probe in order to obtain high performances and to scale down the probe.

변압기 잔류자속 측정에 관한 연구 (A study on the Measurement of Residual Flux for Transformer)

  • 김영학
    • 융합정보논문지
    • /
    • 제12권5호
    • /
    • pp.133-138
    • /
    • 2022
  • 누설자속으로 변압기의 잔류자속을 구하는 기존의 연구에서는 전달함수를 이용하였다. 전달함수는 변압기의 ±의 두 잔류 점을 지나는 순간에 측정한 잔류자속과 동일한 순간에 변압기 밖에서 구한 누설자속으로 구하였다. 본 연구에서는 전달함수를 구하지 않고 동작 최대의 누설자속과 잔류자속에 의한 누설자속의 비를 계산하여 잔류자속을 구하는 방법이 가능함을 확인하였다. 이 방법의 장점은 전류잡음으로 인한 전달함수의 불확정성을 피하는 것이다. 그리고 센서의 잡음을 측정하여 잡음의 드리프트가 측정결과에 미치는 영향을 조사하였다. 잔류 누설 자속밀도를 센서의 드리프트인 80nT와 비교하면 거리 10mm에서는 약 66배, 100mm에서는 5배 이상이었다. 측정거리 100mm는 본 연구에서 얻어진 잔류자속을 구하기 위한 최대 측정 거리였다.

누설자속탐상법의 결함검출능력 향상에 관한 연구 (Improvement in Probability of Detection for Leakage Magnetic Flux Methods)

  • 이진이
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.13-18
    • /
    • 2004
  • It is important to estimate the distribution of intensity of a magnetic field for application of magnetic method to industrial nondestructive evaluation. Magnetic camera provides the distribution of a quantitative magnetic field with homogeneous lift-off and same spatial resolution. Leakage magnetic flux near the crack on the specimen could be amplified by 3-dimensional magnetic fluid and zoom in and out of measurement area. This study introduces the experimental consideration of the effects of lens for concentrating of magnetic flux. The experimental results showed that the magnetic fluid has sufficient lens effect for magnetic camera and effect of improvement in probability of detection.

  • PDF

자기 포화와 누설자속이 고려된 자기등가회로법을 이용한 클로우 폴 스테핑 모터의 요크 형상 설계 (Yoke Shape Design of Claw-Poles Stepping Motor Using Modified Magnetic Equivalent Circuit Method Including Magnetic Saturation Effect and Leakage Flux)

  • 이형우;조수연;배재남;손병욱;박경진;이주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1942-1946
    • /
    • 2009
  • This paper presents a shape design process of Claw-Poles Stepping Motor(CPSM) using Modified Magnetic Equivalent Circuit Method(MMEC). Because this motor is adopted on low power devices, the motor size is a very small type. But it have a very strong permanent magnet. So magnetic saturation effect happens on yoke teeth of CPSM. Also this magnetic saturation effect causes more leakage flux component between yoke tooth have another pole. In this motor type, it is essential to design a shape of yoke teeth for avoiding the magnetic saturation effect and the leakage flux. In this paper, MMEC including the magnetic saturation effect and the leakage flux component was used for design process. Comparing with data calculated by using the MMEC and results analyzed by 3-D FEM, it could be stated that the design process with MMEC was reasonable. Finally, the model has the optimized shape of yoke teeth was compared with a conventional model for no-load Back EMF and torque at steady-state operation.

Circular Holes Punched in a Magnetic Circuit used in Microspeakers to Reduce Flux Leakage

  • Xu, Dan-Ping;Jiang, Yuan-Wu;Lu, Han-Wen;Kwon, Joong-Hak;Hwang, Sang-Moon
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.387-392
    • /
    • 2016
  • Lower flux leakage designs have become important in the development of microspeakers used in thin and miniaturized mobile phones. We propose four methods to reduce the flux leakage of the magnetic circuit in a microspeaker. Optimization was performed based on the proposed approach by using the response surface method. Electromagnetic analyses were conducted using the finite element method. Experimental results are in good agreement with the simulated results obtained in one degree-of-freedom analysis from 100 to 5 kHz. Both the simulated and experimental results confirm that one of the proposed methods is much more effective in reducing flux leakage than the other methods. In the optimized method, compared with a default approach, the average radial flux density in the air gap decreased only by 5.5%, the maximum flux leakage was reduced by 28.6%, and the acoustic performance at primary resonance decreased by 0.45 dB, which gap is indiscernible to the human ear.

Locating Mechanical Damages Using Magnetic Flux Leakage Inspection in Gas Pipeline System

  • Kim, Jae-Joon
    • 비파괴검사학회지
    • /
    • 제30권6호
    • /
    • pp.521-526
    • /
    • 2010
  • Gas transmission pipelines are often inspected and monitored using the magnetic flux leakage method. An inspection vehicle known as a "pig" is launched into the pipeline and conveyed along the pipe by the pressure of natural gas. The pig contains a magnetizer, an array of sensors and a microprocessor-based data acquisition system for logging data. This paper describes magnetic flux leakage (MFL) signal processing used for detecting mechanical damages during an in-line inspection. The overall approach employs noise removal and clustering technique. The proposed method is computationally efficient and can easily be implemented. Results are presented and verified by field tests from an application of the signal processing.

자기누설탐상시스템에서 밀집된 다수의 결함에 의한 탐상 신호 왜곡에 관한 연구 (Study on the Distortion of Detecting Signals with the Multi-Defects in Magnetic Flux Leakage System)

  • 서강;김덕건;한재만;박관수
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.876-883
    • /
    • 2007
  • The magnetic flux leakage(MFL) type nondestructive testing(NDT) method is widely used to detect corrosion, defects and mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Hall sensors detect the leakage fields in the region of the defect. The defects are sometimes occurred in group. The accuracy of the detecting signals in this defect cluster become lowered because of the complexity of the defect cluster. In this paper, the effects of the multi -defects are analyzed. The detecting signals are computed by 3-dimensional finite element method and compared with real measurement. The results say that, rather than the size of the defects, the effects of the relative position of the multi-defects are very important on the detecting signals.