• Title/Summary/Keyword: Leakage Direction

Search Result 190, Processing Time 0.029 seconds

Field Test Facilities for Composite Long Rod Insulator (고분자(高分子) 장간애자용(長幹碍子用) 옥외(屋外)시험장(試驗場) 구축(構築))

  • Hahn, Key-Man;Kim, Dong-Wook;Kwon, Hyuk-Sam;Yoo, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1499-1501
    • /
    • 1994
  • This paper studies on the outdoor field test facilities which are established for weather-resist and mechanical-resist property teat of composite insulator. We have established measuring and data acquisition system for various test conditions -leakage current, temperature, humidity, wind direction, wind velocity and rainfall. The merry-go-round test and salt fog test have been studied in order to evaluate non tracking property of rubber material. Especially we have checked the relationship between hydrophobicity and outdoor exposure degree by contact angle measurement.

  • PDF

Film Compensation based on Discotic Film in Fringe Field Switching Mode

  • Hwang, Seong-Han;Jung, Byoung-Sun;Kim, Seong-Su;Lee, Seung-Hee;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.527-530
    • /
    • 2007
  • Film compensation to suppress a light leakage in the dark state of fringe-field switching (FFS) at off normal direction was performed by optimizing retardation value of discotic (negative A) and TAC films including in-plane switching (IPS). The normal FFS mode shows wide viewing angle characteristics that region of CR 10:1 is over $70^{\circ}$ of polar angle in all directions. The optimized FFS cell exhibits much better performances than other methods do in terms of CR and color uniformity.

  • PDF

A Study on the Mitigation Schemes of Thermal Stratification Phenomenon in a Branch Piping (분기배관에서의 열성층 현상 완화방안에 관한 연구)

  • Park Man-Heung;Kim Kwang-Chu;Lee Seung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.603-611
    • /
    • 2006
  • A variety of schemes were sought for a mitigation of thermal stratification phenomenon in the branch piping of domestic nuclear power plant. Several mechanisms of thermal stratification occurrence were introduced in this paper. A number of factors were selected to find out the schemes for thermal stratification mitigation and the computational analysis were performed. The length of vertical branch piping, the diameter, the radius of curvature of the elbow, the direction of connection between main piping and branch piping, the slope of branch piping, the leakage flow rate, the installation of additional valve, the change of the 1st valve position and another branch piping connected with branch piping were mentioned as factors in this paper.

Analysis of Electromigration in Nanoscale CMOS Circuits

  • Kim, Kyung Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • As CMOS technology is scaled down more aggressively, the reliability mechanism (or aging effect) caused by the diffusion of metal atoms along the conductor in the direction of the electron flow, also called electromigration (EM), has become a major reliability concern. With the present of EM, it is difficult to control the current flows of the MOSFET device and interconnect. In addition, nanoscale CMOS circuits suffer from increased gate leakage current and power consumption. In this paper, the EM effects on current of the nanoscale CMOS circuits are analyzed. Finally, this paper introduces an on-chip current measurement method providing lifetime electromigration management which are designed using 45-nm CMOS predictive technology model.

Influence of Rolling Friction in Linear Ball Guideways on Positioning Accuracy

  • Tanaka, Toshiharu;Ikeda, Kyohei;Otsuka, Jiro;Masuda, Ikuro;Oiwa, Takaaki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.85-89
    • /
    • 2007
  • Linear ball guideways have been used recently in precision or ultra-precision positioning devices. However, when the inner balls begin to roll or the moving direction reverses, these guideways are subject to rolling friction or nonlinear spring behavior. An ultra-precision device with a linear motor, referred to as a 'tunnel actuator' (TA), has been constructed to measure these phenomena. The application of a TA is beneficial for two reasons: it mostly cancels the attractive magnetic force between the stator and mover (armature), and its magnetic flux leakage is very low. The influence of the nonlinear spring behavior in ball guideways was investigated in this study using the pure driving force from a TA. The equilibrium between the driving force from the TA and the nonlinear spring force provided great accuracy for a positioning stage using a linear ball guideway.

Carbonization Behavior due to Surface Tracking (연면 트래킹에 의한 탄화 거동)

  • Jung, Yeon-Ha;Jang, Tae-Jun;Shong, Kil-Mok;Roh, Young-Su;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • In this paper, we are studied on the direction and formation of carbonized conductive path according to surface leakage current between electrodes. The characteristics of the tracking as surface is broken down between exposed live parts. Using the HSIS(high speed imaging system. 100,000[fps], redlake ltd., USA), it took photographs by arc growth mechanism occurred in on/off surge, ground fault and discharge between electrodes. Then the results was analyzed. Hereafter, it expected effects that application of energy utility technology through the arc control.

A Method for Indentifying Broken Rotor Bar and Stator Winding Fault in a Low-voltage Squirrel-cage Induction Motor Using Radial Flux Sensor

  • Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.666-670
    • /
    • 2011
  • In this paper, a method for detecting broken rotor bar and stator winding fault in a low voltage squirrel-case induction motor using an air-gap flux variation analysis is proposed to develop a simple and low cost diagnosis technique. To measure the leakage flux in radial direction, a radial flux sensor is designed as a search coil and installed between stator slots. The proposed method is able to identify two kinds of motor faults by calculating load condition of motors and monitoring abnormal signals those are related with motor faults. Experimental results obtained on 7.5kW three-phase squirrel-cage induction motors are discussed to verify the performance of the proposed method.

Performance Analysis of Linear Brake by Using Efficient 2-D Model (유효한 2차원 모델을 이용한 리니어 브레이크 성능 해석)

  • Han, Pil-Wan;Chun, Yon-Do;Lee, Ju;Lee, Kwan-Seop
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.601-607
    • /
    • 1998
  • This paper presents the efficient 2-D linear brake analysis model which can compensate the lateral leakage flux by changingng the airgap length and magneto-motive force(MMF). The linkage flux of the 2-D analysis is larger than that of 3-D analysis. This is caused by the assumption in 2-D analysis that geometric and physical values are constant along the perpendicular direction(z) to the analysis region. The equivalent MMF have been calculated from the linkage flux difference between the 2-D and 3-D analyses which are performed at zero velocity. The performances of the linear brake have been analyzed effectively by using the compensated 2-D models without using 3-D FEM.

  • PDF

Analyses on Solute Transport with the Movement of an LNAPL on the Water Table (지하수면 위의 LNAPL 이동을 고려한 용질이동에 대한 분석)

  • 김지훈;최종근
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • A modified model was developed for solute transport in porous media that can consider the movement of an LNAPL above the water table. From the results of sensitivity analyses with and without considering LNAPL movement, there are some differences according to the hydraulic gradient, the quantity of oil leakage and dispersivity. The mean deviation between the model in this study and a conventional model without LNAPL movement increases as the hydraulic gradient decreases and the quantity of oil leakage increases. Variation of dispersivity has no influence on the magnitude of the mean deviation. However, the spatial distribution of the deviation between the two models is wider as dispersivity increases. Furthermore, groundwater is at high risk of contamination in the vertical direction in the case that transverse dispersion value is large. A conventional model underestimates the concentration of solute in an aquifer where the movement of an LNAPL cannot be negligible: Based on the study results, it is important to understand how fast the LNAPL moves on the water table for realistic prediction of solute transport in an aquifer with the movable LNAPL on the water table.

Cross-Shaped Magnetic Coupling Structure for Electric Vehicle IPT Charging Systems

  • Ren, Siyuan;Xia, Chenyang;Liu, Limin;Wu, Xiaojie;Yu, Qiang
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1278-1292
    • /
    • 2018
  • Inductive power transfer (IPT) technology allows for charging of electric vehicles with security, convenience and efficiency. However, the IPT system performance is mainly affected by the magnetic coupling structure which is largely determined by the coupling coefficient. In order to get this applied to electric vehicle charging systems, the power pads should be able to transmit stronger power and be able to better sustain various forms of deviations in terms of vertical, horizontal direction and center rotation. Thus, a novel cross-shaped magnetic coupling structure for IPT charging systems is proposed. Then an optimal cross-shaped magnetic coupling structure by 3-D finite-element analysis software is obtained. At marking locations with average parking capacity and no electronic device support, a prototype of a 720*720mm cross-shaped pad is made to transmit 5kW power at a 200mm air gap, providing a $1.54m^2$ full-power free charging zone. Finally, the leakage magnetic flux density is measured. It indicates that the proposed cross-shaped pad can meet the requirements of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) according to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA).