• 제목/요약/키워드: Leak test

검색결과 257건 처리시간 0.024초

실배관 파괴특성 평가에 관한 연구 (I) (A Study on the Evaluation of the Pipe Fracture Characteristic (I))

  • 박재실;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.345-350
    • /
    • 2001
  • In order to perform elastic-plastic fracture mechanical analyses, fracture resistance curves for concerned materials are required. 1T-CT specimen was used to obtain fracture resistance curves. But the fracture resistance curve by the 1T-CT specimen was very conservative to evaluate the integrity of the structure. And fracture resistance curve was affected by the specimen geometry and crack plane orientation. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the 1T-CT specimen and to provide the additional safety margin. For these, the fracture tests using the real pipe specimen and standard 1T-CT specimen test were performed. 4-point bending jig was manufactured for pipe test and direct current potential drop method was used to measure the crack extension and length for pipe test. From the pipe and the 1T-CT specimen test results, it was observed that the J-integral of the 1T-CT specimen test at the crack initiation point was very small compare to that of the pipe specimen test.

  • PDF

원전 단종 밸브의 DED 방식 금속 3D프린팅 제작 및 성능시험 (Manufacturing and Performance Test of Obsolete Valve in NPP using DED Metal 3D Printing Technology )

  • 장경남
    • 한국압력기기공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.75-82
    • /
    • 2021
  • The 3D printing technology is one of the fourth industrial revolution technology that drives innovation in the manufacturing process, and should be applied to nuclear industry for various purposes according to the manufacturing trend change. In nuclear industry, it can be applied to manufacture obsolete items and new designed parts in advanced reactors or small modular reactors (SMRs), replacing the traditional manufacturing technologies. A gate valve body was manufactured, which was obsolete in nuclear power plant, using DED(Directed Energy Deposition) metal 3D printing technology after restoring design characteristics including 3D design drawing by reverse engineering. The 3D printed valve body was assembled with commercial parts such as seat-ring, disk, stem, and actuator for performance test. For the valve assembly, including 3D printed valve body, several tests were performed, including pressure test, end-loading test, and seismic test according to KEPIC MGG and KEPIC MFC. In the pressure test, hydraulic pressure of 391kgf/cm2 was applied to 3D printed valve body, and no leak was detected. Also the 3D printed valve assembly was performed well in end-loading and seismic tests.

Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구 (A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3))

  • 이숙경;김광신;손순환;송규민;이계우;박정서;조병호;유병재;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.311-318
    • /
    • 2010
  • 공학적 안전설비 공기정화계통의 규제지침인 Reg. Guide 1.52(Rev.3)의 변경사항중 성능시험과 관련한 운전가능성 시험시간 단축, HEPA 필터 현장누설시험용 시험물질 변경 및 활성탄 성능시험 Methyl Iodidie 투과허용율 상향 변경을 영광 5,6호기에 적용하고자, 모사실험장치와 현장 설비를 활용하여 기술적 타당성을 확인하는 실험을 수행하였다. 10시간 이상의 장시간 운전가능성 시험을 통해 계통내 습분을 제거하여도 시험후 1~4일만에 회복됨을 확인하여 운전가능성 시험은 기기적 운전가능성 점검에 적합한 매월 15분 이상의 시험을 수행하는 것이 타당함을 확인하였다. HEPA 필터 현장누설시험용 시험물질 변경을 위해 DOP와 PAO의 에어로졸 입자크기, 발생량, 누설인지도를 비교한 결과 PAO는 원전에서도 DOP 대체시험물질로 사용 가능함을 확인하였다. 베드깊이 4 인치 이상의 활성탄여과기에 대한 Methyl Iodide의 투과율 허용치가 0.175 %에서 0.5 %로 상향 변경된 것은, ASTM D3803(1989)으로의 활성탄 성능시험 방법 변경에 따른 것으로서, $30^{\circ}C$ 상대습도 95 %에서의 Methyl Iodide 투과허용율 0.5 %가 사용 중 활성탄의 성능을 시험하기에 충분히 보수적인 시험방법임을 확인하였다. 본 실험 결과를 바탕으로 영광 5,6호기는 인허가변경을 완료하였다.

콘크리트 지하구조물 누수 처리를 위한 유도배수시스템 (Drainage system for leakage treatment of cement concrete structure in underground)

  • 김동규
    • 한국터널지하공간학회 논문집
    • /
    • 제21권4호
    • /
    • pp.573-585
    • /
    • 2019
  • 본 연구의 목적은 운영 중인 콘크리트 지하구조물에서 발생하는 누수를 유도배수하기 위하여 시공성, 차수 및 유도배수 성능을 향상시킨 유도배수시스템을 제안하는 것이다. 기존 유도배수시스템에서 제기된 유도배수관의 시공성 및 누수를 개선하였다. 개선된 유도배수관을 적용한 유도배수시스템은 시공성, 차수 및 유도배수 성능에 대한 현장평가를 위하여 재래식 콘크리트 라이닝 터널에서 시험 시공되었다. 재령 3주, 6주, 9주, 11주, 14주, 17주 및 23주차에 개선된 유도배수시스템 배면에 약 1,000 ml 이상의 붉은색 물을 주입하여 유도배수시스템의 차수와 유도배수 성능을 평가하였다. 현장 성능평가 실험이 진행된 6개월 동안 터널이 위치한 지역의 일일 평균 온도는 $-12.4{\sim}19.7^{\circ}C$이며 일일 최저 온도는 $-17.2^{\circ}C$이고 일일 최고 온도는 $26.7^{\circ}C$였다. 현장 성능평가 실험이 진행되는 6개월 동안 개선된 유도배수시스템에서는 누수가 발생하지 않았다. 또한 개선된 유도배수관에서도 누수가 발생하지 않았다. 개선된 유도배수시스템은 누수가 발생하는 다양한 콘크리트 지하구조물에서 적용가능하며 계절적 영향도 거의 받지 않는 것으로 판단되었다.

회전압축기형 스털링 냉동기의 열환경 성능시험에 관한 연구 (A Study on Thermal Environmental Performance Test of the Rotary Compressor Stirling Cryocooler)

  • 박성제;홍용주;김효봉;김대웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1953-1958
    • /
    • 2007
  • This paper presents the results of a series of performance tests for the integral Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Integral Stirling cryocooler for thermal imaging system have matured to the stage of undergoing formal qualification test program. The thermal environmental test of the Stirling cryocooler is presented in this paper. We performed that low and high temperature keeping test from $-40^{\circ}C$ to $+71^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooldown time to 80K and steady state input power at 80K were determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooldown time to 80K of less than 5 minutes 24seconds for $71^{\circ}C$ ambient temperature with input power of 11W

  • PDF

내장형 레귤레이터 및 솔레노이드 개발 (Development of In-tank Pressure Regulator and Solenoid Valve)

  • 이준혁;임태호;김경남;심상학
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.188-191
    • /
    • 2007
  • This paper shows the Development of In-tank pressure regulator and Solenoid Valve used in FCV(Fuel Cell Vehicle). We have developed new type of Regulator and Solenoid through analysis of the structure and characteristics of component of FCS(Fuel Cell System) from the advanced technology. Now it is possible to localize the component by making use of the development of Regulator and Solenoid made by us. Regulator and Solenoid is a equipment to control hydrogen pressure supplied into a stack. Therefore, outlet pressure, a flow of fluid and temperature are important parameters according to a inlet pressure. And leak test, endurance test and burst test should be done to guarantee the performance and safety of Regulator and Solenoid used in the fuel of high pressure. Also, Hydrogen friendly materials are applied to inner parts of the Regulator, Solenoid and weight reduction is done to cost saving in part not related to performance. As a result, we have proven the good performance and reliability in endurance of Regulator, Solenoid and will make an development in performance as well as durability to ensure industrialization.

  • PDF

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

초고온융 공기예열식 열교환기의 개발 및 성능 평가 (The Development and Performance Evaluation of the Air-preheating Heat Exchanger for Ultra-high Temperature Applications)

  • 박용환
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.78-84
    • /
    • 1999
  • A compact air-preheating type heat exchanger was developed and tested for the ultra-high temperature heat recovery applications. For the direct use of exhaust gases up to $1200^{\circ}C$, the heat exchanger adopted a ceramic core with high strength and low thermal expansion coefficient less than $1{\times}10^{-6}^{\circ}C^{-1}$. The ceramic core was fabricated by special extrusion and bonding techniques. To minimize thermal stresses in the core, spring-loaded sealing mechanism was designed and successfully installed. 1-pass air flow scheme was adopted for the compactness and cost-savings. The pressure test for the ceramic core showed no failure under 35 kPa and less than 3% leak under 7 kPa. Flue gas simulation system was developed to investigate the performance of the heat exchanger. The test results showed normal operations of the heat exchanger up to $1200^{\circ}C$ of exhaust gases and relatively high heat recovery efficiencies of 31~39% depending upon exhaust gas temperatures..

  • PDF

영광원자력 배관소재의 재료물성치 평가 (1)-정지냉각계통- (Evaluation of Material Properties for Yonggwang Nuclear Piping System(I)-Shutdown Cooling System-)

  • 석창성;최용식;장윤석;김종욱
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1106-1116
    • /
    • 1994
  • Leak Before Break(LBB) design concept is applied to piping systems of newly-built Yonggwang 3, 4 nuclear generating stations as a design alternative to the provision of pipe whip restraints, in recognition of the questionable benefits of providing such restraints. The objective of this paper is to evaluate the material properties (tensile and fracture toughness) of SA312 TP316 stainless steel and their associated welds manufactured for shutdown cooling system of Yonggwang 3, 4 nuclear generating stations. Effect of various parameters such as specimen orientation, test temperature, welding on material properties were examined.

액체로켓엔진 산화제(과산화수소) 공급계 구축에 관한 연구 (The study of manufacturing the oxidizer(Hydrogen Peroxide) feeding system of liquid rocket engine)

  • 전준수;정재훈;김유;고영성;김선진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2009
  • 본 연구에서는 액체로켓엔진 산화제로 과산화수소를 사용하기 위한 공급 설비 구축 및 세척 방법을 제시하고자 한다. 과산화수소 공급 설비의 오염을 최소화하기 위하여 공급 설비를 세척하고 세척된 공급 설비에 보호막을 입히는 passivation 절차를 확립하였다. 또한, 구축된 공급 설비는 누설 시험과 연소 시험을 통해서 안정성을 검증하였다.

  • PDF