• Title/Summary/Keyword: Leak effect

Search Result 179, Processing Time 0.018 seconds

Deterministic Fracture Mechanics Analysis of Nuclear Reactor Pressure Vessel Under Rot Leg Leak Accident (고온관 누설에 의한 가압열충격 사고시 원자로 용기의 건전성 평가를 위한 결정론적 파괴역학 해석)

  • Lee, Sang-Min;Choi, Jae-Boong;Kim, Young-Jin;Park, Youn-Won;Jhung, Myung-Jo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2219-2227
    • /
    • 2002
  • In a nuclear power plant, reactor pressure vessel (RPV) is the primary pressure boundary component that must be protected against failure. The neutron irradiation on RPV in the beltline region, however, tends to cause localized damage accumulation, leading to crack initiation and propagation which raises RPV integrity issues. The objective of this paper is to estimate the integrity of RPV under hot leg leaking accident by applying the finite element analysis. In this paper, a parametric study was performed for various crack configurations based on 3-dimensional finite element models. The crack configuration, the crack orientation, the crack aspect ratio and the clad thickness were considered in the parametric study. The effect of these parameters on the maximum allowable nil-ductility transition reference temperature ($(RT_{NDT})$) was investigated on the basis of finite element analyses.

A Study on the Clamping Force of an Automotive Air-conditioning Hose according to the Friction Coefficient (마찰계수를 고려한 자동차용 에어컨 호스의 체결력에 관한 연구)

  • Baek, Jae-Kwon;Kim, Byung-Tak
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.39-46
    • /
    • 2011
  • The automotive air conditioning hose is used for connecting the components of air conditioner in a vehicle. The hose is usually manufactured by the swaging process to connect the rubber hose with the metal fitting at the end of the hose. In case that the clamping force is small, the refrigerant gas in the hose can leak locally under the severe operating circumstances. The practical test of clamping force is performed by means of the measurement of separation force. In this study, the swaging process of a hose is simulated with the finite element method, to investigate the effect of friction coefficient on the clamping force. The contact condition is used in consideration of real manufacturing process, and the material properties for the Mooney-Rivlin model is obtained by the experimental results. The result interpretations are focused on the contact forces, which is displayed graphically with respect to friction coefficient, on the surfaces between the hose and the metal fittings.

Diseases of Aquaculture animals and prevention of Drug Residues (양식어류의 질병과 수산동물용 의약품의 잔류방지 대책)

  • 허강준;신광순;이문한
    • Journal of Food Hygiene and Safety
    • /
    • v.7 no.2
    • /
    • pp.107.2-119
    • /
    • 1992
  • Fish pathology is one of the main scientific bases upon which this expansion in aquaculture has been dependent and requires a wide knowledge of the environmental constraints, the physiology and characteristic of the various pathogens, the responses of the host, and the methods by which they may be controlled. The primary disease and parasite problems in aquaculture animals related to viral, bacteria, fungal and protozoan epizootics. Parasitic nematodes, trematodes and cestodes are commonly found in aquaculture animals, but seldom are they present in concentrations sufficient to cause significant problems, When an epizootic does occur and chemical treatment is indicated, the appropriate chemical must be selected an properly applied. We have antibiotics, sulfa, nitrofuran and other chemicals for treatment of fish diseases, Some may be mixed with the feed during formulation, added to the pellets of feed as a surface coating, given in the form of an injection or used as a bath. Even though a drug or chemical has been officially approved for use in aquaculture, the substance should never be used unless there is a clear need, Some of the reasions for this view are as follows: (1) the constant use of antibiotics can leak to the development of resistant strains of bacteria, (2) biofilter efficiency may be impaired or destroyed by chemicals added to closed recirculating water systems, and(3) the injudicious use of chemical can have a damaging effect on the environment as well as on human.

  • PDF

A Study on Fusion Welding Strength of PE pipe (PE배관의 융착 강도에 관한 연구)

  • Jun, Hung-Won;Kim, Yong-Soo;Tae, Soon-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.16-21
    • /
    • 2002
  • At present the Polyethylene piping, on supporting LNG is widely used because of it's disposition which are anti-corrosion flexible and so on. However, it has a few kinds of risk which are the possibility of piping leak, the character of easily corroded and so on. For giving solution, this study is intended to experiment the intension of the PE pipe after melted and when it is melting, the condition which are temperature and pressure is changed. the melting condition in temperature and pressure is adapted identically. After melting, it's joint is tested as intension. The result is that the effect of temperature in intension is more effective than pressure. In $210^{\circ}C$, $20kg/cm^{2}$ condition, the melting intension has the highest. Compare to the Butt melting joint and the Saddle melting joint, the former was $214kg/cm^{2}$ and the latter was $50kg/cm^{2}(bead\;2{\sim}3mm)$ and $73kg/cm^{2}(bead\;5{\sim}7mm)$. It means that the Butt melting method has more intensive than saddle. Consequently, the result shows that the liability and safety when pipe melting method is used will improve in pipe installation.

The Design of Active Storage Virtualization System for Information Protection (정보보호를 위한 능동적 스토리지 가상화 시스템 설계)

  • Cho, Kyoung-Ok;Han, Seung-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2040-2048
    • /
    • 2010
  • In contemporary society, though convenience and efficiency of work using information system is growing high, adverse effect problems of malignant code, system hacking, information leak by insiders due to the development of the network are raising their head daily. Because of this, enormous work forces and expenses for the recovery and management of system is needed. The existing system can be divided into two aspects: security solution which surveils and treats virus and malignant codes, and network management solution which observes the system of computer, and practices maintenance and repair such as management, recovery, backup. This treatise applied Active Write Filter mechanism and the technology based on NFS and complemented the maintenance problems of user data of the existing system and designed the system which enables solving problems of intellectual property right such as information protection and illegal work.

A System IC for Controlling the Fire Prevention (화재방지제어 시스템 IC)

  • Kim, Byung-Cheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.737-746
    • /
    • 2009
  • In this study, we have developed one chip system IC for preventing the overload, detecting an abnormal conditions, and controlling the fire prevention in the intelligent home appliances. For the purpose, a circuit detectable an electric leak for preventing an electric shock, and a circuit detectable arc that has effect directly on the fire are designed. The circuits designed on every block are verified by comparing simulation with bread-boarding using a standard transistors. The system IC is fabricated by using 34 V 2 metal $1.5{\mu}m$ bipolar transistor process from evaluation results. The electrical performances of IC application circuits and the system IC equipped on PCB board are evaluated. It is confirmed that the system IC is well operated for arc and ground fault(GF) signal.

Effect of Inspection on Failure Probability of Pipes in Nuclear Power Plants (원전 배관의 파손확률에 대한 검사의 영향)

  • Park, Jai-Hak;Choi, Young-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1249-1254
    • /
    • 2012
  • Pipe inspections conducted in nuclear power plants play an important role in ensuring the structural integrity of pipes. Because considerable manpower and expense is required for pipe inspections, it is very important to determine the optimum inspection period and the level of inspection. In this study, the effects of the period and the inspection quality on the failure probability of pipes are investigated using the P-PIE program, which has been developed to calculate the failure probability of pipes. The pipe data of an internal nuclear power plant is used in the study, and fatigue and stress corrosion crack growth are considered in the analysis.

Stellar populations of Galactic Globular Cluster $\omega$ Cen using HST/WFC3 near-UV observations

  • Kim, Eun-Hyeuk;Joo, Seok-Joo;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.54.2-54.2
    • /
    • 2010
  • The most massive galactic globular cluster, $\omega$ Cen has been observed using recently mounted WFC3/UVIS cameras of Hubble Space Telescope at both near-UV and optical bands. We present the photometry of stars in the central region of $\omega$ Cen in F225W, F275W and F336W bands. The near-UV color-magnitude diagrams and color-color diagrams of stars in $\omega$ Cen show multiple red giant branches and main sequences as already discovered in both ground-based and HST/ACS observations in the optical bands. We modelled the stellar populations of $\omega$ Cen using Yonsei Isochrone, where $\alpha$-particles and helium enhancement processes have been included properly. We compare the best-fit stellar populations obtained from the current near-UV observations to the suggested stellar population models based on optical band data. We also discuss the methodological issues arising when dealing with the near-UV observations; red-leak in near-UV filters and the huge interstellar extinction in near-UV bands compared to the optical bands and its non-linear effect in color-magnitude diagrams.

  • PDF

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Leaking Flow in a T-Branch of Square Cross-Section (난류침투가 사각단면 T분기관 내 누설유동에 의해 발생한 열성층 현상에 미치는 영향)

  • 홍석우;최영돈;박민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. $textsc{k}$-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of the main flow in the duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from the main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.

Optimization of Conduction-cooled Pottier Current Leads (전도냉각형 펠티어 전류도입선의 최적화)

  • Jeong, Eun-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.764-771
    • /
    • 2005
  • A theoretical investigation for optimization of conduction-cooled Peltier current leads is undertaken. A Pottier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high Tc superconductor (HTS) lead in the order of decreasing thermoelectric tempera ture. Mathematical expression for the minimum heat flow per unit current crossing the TE metal interface and that flowing from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE-metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the 73 and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.