• Title/Summary/Keyword: Leak accidents

Search Result 134, Processing Time 0.023 seconds

Smart Home Safety Platform Program for City Gas Leakage (도시가스 누출에 따른 스마트 홈 안전 플랫폼 프로그램 구축)

  • Ji, HyunMin;Lee, Ugwiyeon;Oh, Jeongseok
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.97-102
    • /
    • 2019
  • In this study, city gas is the most commonly used in homes, and gas accidents are increasing as demand increases. Among them, accidents due to user carelessness are the most and we try to provide information by establishing scenarios to effectively prevent this. The gas leak in the home is an enclosed space, and the appropriate Gaussian model is applied. As smart home control technology is developed by the 4th industrial revolution, it will make a foundation to provide information through program to predict and prevent gas leakage accidents and apply it to smart home safety platform.

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

A leak detection and 3D source localization method on a plant piping system by using multiple cameras

  • Kim, Se-Oh;Park, Jae-Seok;Park, Jong Won
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.155-162
    • /
    • 2019
  • To reduce the secondary damage caused by leakage accidents in plant piping systems, a constant surveillance system is necessary. To ensure leaks are promptly addressed, the surveillance system should be able to detect not only the leak itself, but also the location of the leak. Recently, research to develop new methods has been conducted using cameras to detect leakage and to estimate the location of leakage. However, existing methods solely estimate whether a leak exists or not, or only provide two-dimensional coordinates of the leakage location. In this paper, a method using multiple cameras to detect leakage and estimate the three-dimensional coordinates of the leakage location is presented. Leakage is detected by each camera using MADI(Moving Average Differential Image) and histogram analysis. The two-dimensional leakage location is estimated using the detected leakage area. The three-dimensional leakage location is subsequently estimated based on the two-dimensional leakage location. To achieve this, the coordinates (x, z) for the leakage are calculated for a horizontal section (XZ plane) in the monitoring area. Then, the y-coordinate of leakage is calculated using a vertical section from each camera. The method proposed in this paper could accurately estimate the three-dimensional location of a leak using multiple cameras.

Constructing a Database Structure for the Domestic LP Gas and Natural Gas Accidents and its Analysis (국내 LP 및 천연가스사고 Database 구축 및 분석에 관한 연구)

  • Ko, Jae-Sun;Park, Sun-Young;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.56-63
    • /
    • 2008
  • We have garnered 3,593 data of gas [Natural Gas (NG) and Liquefied Petroleum Gas (LPG)] accidents reported for 16 years from 1991, and then analyzed the accidents according to their types and causes based on the classified database. According to the results the gas leak has been the most common accident followed by the explosion and then fire accidents. The most frequent accident-occurring locations for fire, explosion and leak are recognized around the valve, hose and pipeline, respectively. In addition, we have applied the Poisson analysis to predict the most-likely probabilities of fire, explosion and release in the upcoming 5 years. From this research we have assured the successive database updating will highly improve the anticipating-probability accuracy and thus it will play a key role as a significant safety-securing guideline against the gas disasters.

  • PDF

A Study on the Water Absorption Diagnosis Method through Capacitance Measurement for Generator Stator Windings (발전기 고정자 권선의 정전용량 측정을 통한 흡습 진단 방법에 관한 연구)

  • Kim, Hee-Soo;Bae, Yong-Chae;Kee, Chang-Doo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.50-57
    • /
    • 2006
  • The water leak in water-cooled generator stator windings can generate the serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them for the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. The developed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

Discussions on the Leak Phenomena of Liquid Butane in the Open Air (액화석유가스(butane)의 대기중 누출현상에 대한 고찰)

  • Yoon, Jae-Kun
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2000
  • Almost accidents related with gas have started with the leakage of LPG(Liquefied Petroleum Gas) in the open air. But experimental data of LPG leak jet are difficult to find because the safety of experiment is hard to secure and its phenomenon is not steady but transitional. This study is focused on the phenomena of injection jet of liquid butane to the open air. Simple experiment shows that only liquid butane jet in the open air is possible due to the slow vaporization because of low temperature difference between the liquid and air and low vapor pressure of liquid butane. Comparing with the water, 25~40% more liquid butane flow through the tube under the same pressure difference driving.

  • PDF

AN ARTIFICIAL NEURAL NETWORK BASED SENSOR SYSTEMS FOR GAS LEAKAGE MONITORING

  • Ahn, Hyung-Il;Kim, Eung-Sik;Lee, June-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.282-288
    • /
    • 1997
  • The purpose of this paper is to predict the situation of leak in closed space using an Artificial Neural Network (ANN). The existing system can't monitor the whole He situations with on/off signals. Especially the first stage of data determines the leak spot and intensity is disregarded in gas accidents. To complement these faults, a new prototype of monitoring system is proposed. Ihe system is composed of'sensing systenL data acquisition system computer, and ANN implemented in software and is capable of identifying the leak spot and intensity in closed space. The concentration of gas is measured at the 4 different places. The network has 3 layers that are composed of 4 input Processing Element (PE),24 hidden PEs, md 4 output PEs. The ANN has optimum condition through several experiments and as a consequence the recognition rate of93.75% is achieved finally

  • PDF

Method to Analyze Information Leakage Malware using SSL Communication in Android Platform

  • Cho, Gilsu;Kim, Sangwho;Ryou, Jaecheol
    • Journal of Internet Computing and Services
    • /
    • v.19 no.3
    • /
    • pp.1-6
    • /
    • 2018
  • Widely used around the world, smartphones contain many features and can store content such as contacts, photos, and videos. Information that can be leaked in proportion to the information that the smartphone can store has also been increased. In recent years, accidents such as personal information leakage have occurred frequently. Personal information leakage is happening in the Android environment, which accounts for more than half of the smartphone operating system market share. Analyzing malicious apps that leak information can tell you how to prevent information leakage. Malicious apps that leak information will send importantinformation to the hacker's (C & C) server, which will use network communication. Malicious apps that are emerging nowadays encrypt and transmit important information through SSL communication. In this case, it is difficult to knowwhat kind of information is exposed to network. Therefore, we suggest a method to analyze malicious apps when leak important information through SSL communication. In this paper, we identify the way malicious apps leak information. And we propose a method for analyzing information leaked by SSL communication. Data before encryption was confirmed in the device through SSL hooking and SSL Strip method.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

A Study on Prevention of Accidents of Carbon Monoxide Leak from Gas Boilers (가스보일러 일산화탄소 누출사고 경감에 관한 연구)

  • Song, Jaechang;Kwon, Hweeung;Lee, Younghee;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.277-281
    • /
    • 2012
  • This work is concerned with a plan for preventing accidents of CO gas leak from gas boilers, involving the enforcement of installations of both CO alarm system and condensing boilers, and financial support of government grants. If amongst 1,460,000 beneficiaries of basic livelihood security, one million households in use of gas boilers receive 3-year support of 200,000 won, the difference of prices between common and condensing boilers, the government grants would be 2,000 billion won. If 3 million common householders are in 3-year support of 100,000 won, government grants would be 3,000 billion won. Therefore, 3-year grand total of government grants would be 5,000 billion won. Finance for government grants can be purveyed from energy saving; yearly 2,000 billion won of energy saving by enforcing to replace one million existing boilers with condensing boilers, leading to 2 trillion won of energy saving for 10 years. In this way, 6,000 billion won of 3-year grand total of government grants for CO alarm system and condensing boilers can be purveyed. The rest amount would be fundraised for energy savings. We claim that our proposal can make an achievement of more than 50% reduction of CO leak accidents during 10 years.