실리콘 혼합 차폐체의 개발과 성능비교 (Development and Performance Comparison of Silicon Mixed Shielding Material)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.187-195
    • /
    • 2023
  • A shield was made by mixing materials such as bismuth(Bi) and barium(Ba) with silicon to evaluate its shielding ability. Bismuth was made into a shield by mixing a bismuth oxide(Bi2O3) colloidal solution and a silicon base and applied to a fibrous fabric, and barium was made by mixing lead oxide(PbO) and barium sulfate(BaSO4) with a silicon curing agent and solidifying it to make a shield. The test was conducted according to the lead equivalent test method for X-ray protective products of the Korean Industrial Standard. The experiment was conducted by increasing the shielding body one by one from the test condition of 60 kVp, 200 mA, 0.1sec and 100 kVp, 200 mA, 0.1 sec. At 60 kVp, 2 lead oxide-barium sulfate shields, 2 bismuth oxide 1.5 mm shields, and 5 bismuth oxide 0.3 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. At 100 kVp, 2 lead oxide-barium sulfate shields and 2 bismuth oxide 1.5 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. It was confirmed that when using 2 pieces of lead oxide-barium sulfate and 1.5 mm of bismuth oxide, respectively, it has shielding ability equivalent to that of lead. Bismuth oxide and lead oxide-barium sulfate are lightweight and have excellent shielding ability, thus they have excellent properties to be used as an apron for radiation protection or other shielding materials.

고 에너지 전자선 치료를 위한 3D 프린터 물질의 차폐 성능평가 (Evaluation of Shielding Performance of 3D Printer Materials for High-energy Electron Radiation Therapy)

  • 오창우;배상일;문영민;양현경
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.687-695
    • /
    • 2022
  • 고 에너지 전자선 치료 시 차폐체로 사용되는 납을 대체할 수 있는 3D 프린터 소재를 찾기 위해 MCNP6 프로그램을 사용하였다. 고 에너지 전자선을 방출하는 선형가속기의 PDD(Percent Depth Dose), Flatness, Symmetry를 측정하고, MCNP6로 선형가속기를 모의 모사 후 비교하여 실측과 모의 모사와의 선원항이 일치함을 확인하였다. 납 차폐체를 모의 모사하여, 흡수선량의 95 % 이상을 차폐할 수 있는 납 차폐체의 적정 두께를 선정하였다. 3 mm 두께의 납 차폐체에 대한 흡수선량 데이터를 기준으로 하여 ABS + W(10%), ABS + Bi(10%), PLA + Fe(10%) 소재들의 1, 5, 10, 15 mm 두께 별로 모의 모사로 분석하여 차폐성능을 분석하였다. 3D 프린터로 각각의 시제품을 제작하여 모의 실험과 같은 조건으로 측정하여 분석한 결과 ABS+W(10%) 소재가 최소 10 mm 이상의 두께로 형성되었을 때, 3 mm 두께의 납을 대체할 수 있는 차폐성능을 가지는 것을 확인하였다. 주사전자현미경(SEM)과 EDS 스펙트럼을 이용하여 ABS + W(10%) 소재의 원소조성 및 표면형상을 분석하였다. 이러한 결과를 통해, 상용화 된 납 차폐체를 ABS + W(10%) 소재로 대체하면 납과 같은 차폐효과를 낼 뿐만 아니라 3D 프린터를 이용하여 환자 맞춤형으로 제작할 수 있어 고 에너지 전자선 치료에 매우 유용할 수 있음을 확인하였다.

산화철, 알루미나를 이용한 X선 차폐체 개발 및 성능 평가 (Development and Performance Evaluation of X-Ray Shields using Fe2O3 and Al2O3)

  • 양희수;김지환;전민철
    • 미래기술융합논문지
    • /
    • 제1권2호
    • /
    • pp.19-25
    • /
    • 2022
  • 방사선 차폐 물질인 납을 대신하여 싸고 친환경적인 산화철, 알루미나로 차폐체를 제작 후 차폐체의 성능을 평가하고자 한다. 산화철과 알루미나 각각 석고와 혼합하여 차폐체를 제작 이후 X-ray Tube를 이용하여 석고보드, 납복과 비교하여 성능을 평가한다. 관전압에 변화를 주며 실험한 결과 알루미나의 차폐 성능은 석고보드보다 차폐 성능이 떨어졌으며 50%의 알루미나가 함유되었을 때 석고보드와 차폐 성능이 비슷하였다. 산화철은 약 75%가 함유되었을 때 납복의 차폐 성능과 비슷해졌다. 알루미나를 이용한 차폐체는 석고와 비슷한 차폐 성능을 보여줘 납 대체물질로 적합하지는 않다. 하지만 산화철은 납복과 비슷한 차폐 성능을 나타내어 향후 납을 대체하는 X선 차폐 물질로 활용이 가능하기에 추가 연구가 필요하다.

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정 (Scattering Measurement of Syringe Shield Used in PET/CT)

  • 장동근;박철우;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

감마선 영상화 장치용 경량 고효율 차폐체 최적설계에 관한 연구 (A study on the optimization of light weight high efficiency shield for gamma-ray imaging detector)

  • 박강택;이남호;황영관
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.773-774
    • /
    • 2016
  • 본 논문에서는 감마선원 영상화를 위한 감마선 탐지장치에 적용할 차폐체의 경량, 소형화 연구를 수행하였다. 선행 연구를 통해 상용 감마선 영상화 장치의 차폐체와 유사한 차폐효율 및 성능을 나타내는 납 기반의 차폐체를 구현하였으며, 본 논문에서는 납 기반의 차폐체보다 경량화, 소형화를 위해 텅스텐기반의 차폐체를 설계하였다. 차폐체 설계를 위해서 MCNP 전산모사를 수행하였으며, 그 결과 17%의 경량화 및 51%의 체적을 줄이는 결과를 얻었다.

  • PDF

Provil과 cerrobend을 이용한 electron 차폐물 제작 (The Fabrication of Internal Shielding using Provil and Cerrobend)

  • 김종화;이강현;손정혜
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.37-39
    • /
    • 1996
  • The skin cancer is a highly curable disease which frequently occurs in the head and neck region exposed to the sun. When the eyelid is treated usually eye shield made of lead is used to protect the eyeball as a internal shield. For the same reason on internal shield should be used when the nose is treated when electron to protect the nasal mucosa. Our hospital made an internal shield for the treatment of the skin cancer on the nose using provil and cerrobend. The characteristics of the internal shield were examined.

  • PDF

친환경 소재의 의료 방사선 차폐 시트 개발 ; I: 섬유, 고무, 실리콘 소재 차폐 시트의 성능 비교평가 (Development of Radiation Shield with Environmentally-Friendly Materials ; Ⅰ: Comparison and Evaluation of Fiber, Rubber, Silicon in the Radiation Shielding Sheet)

  • 김선칠;박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.121-126
    • /
    • 2010
  • 영상의학과 검사실을 비롯하여 병원에서 의료방사선 차폐제로 사용되는 대표적인 물질이 납이다. 납은 재질이 연하고 오래 동안 변질되지 않으며, 특히 X(${\gamma}$)선에 대한 선흡수계수가 커서 방사선 차폐제로 매우 유용하다. 그러나 납은 생물학적 구조와 기능에 필요하지 않는 부분이 많아 인체에 과다하게 노출되면 위험하므로 카드뮴, 수은, 비소 등과 같이 중금속으로 분류되어 있다. 이러한 위험성에서 벗어나기 위해서 납과 같은 방사선 차폐능력을 가지고 어떠한 형태로도 가공이 가능한 방사선 차폐물질을 개발하려고 노력하고 있다. 본 연구에서는 인체에 무해한 황산바륨을 이용하여 섬유, 고무, 실리콘에 함유하여 의료방사선 차폐시트를 개발하였고 이를 대상으로 의료방사선 차폐능력을 비교 평가하였다. 평가 결과에 있어서 실리콘에 바륨을 함유하여 제조한 시트가 가장 우수한 차폐능을 보였다.

헬멧형 뇌자도 장치로의 활용을 위한 Pb 초전도 차폐의 특성 (Characteristics of Superconductive Pb shield for a Whole Head MEG System)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.30-35
    • /
    • 2009
  • We have investigated the characteristics of a superconductive Pb shield for hemispherical shape and plate to improving signal-to-noise ratio(SNR) of biomagnetism. We measured the shielding factor for the position of helmet shape Pb and for changing the distance from Pb surface. To make a uniform magnetic field, a $1.5m{\times}1.5m$ set of the helmholtz coils activated at several frequencies. The shielding factor of hemispherical shape Pb was from 20 to 57 dB and of Pb plate was about $6{\sim}26dB$ as a function of distance from the lead surface. The shielding factor was rapidly reduced as increasing the distance from Pb surface. The white noise of superconductive quantum interference device(SQUID) with a superconductive shield was about $12fT/Hz^{1/2}$ at 1 Hz, $7fT/Hz^{1/2}$ at 100 Hz. The white noise was more increased about two times than conventional SQUID system without Pb shielding. An auditory signal was measured by first order gradiometer and magnetometer with Pb superconductive shield and compared the SNR. The SQUID system with Pb shield had better performance at low frequency noise level.

  • PDF

완전차폐시 50MVA급 HTS-케이블 샘플의 교류손실 (AC loss of a 50MVA HTS-cable sample in perfect shielding)

  • 마용호;이주영;진홍범;류경우;임지현;손송호;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.296_297
    • /
    • 2009
  • 다층구조의conductor와 shield로 구성되는 HTS-cable의 교류손실 특성 연구를 위하여 2005년부터 실증시험 중에 있는 22.9kV, 50MVA, 100m급 KEPCO HTS-cable system에 사용된 케이블과 동일한 두개의 short-sample에 대하여DC 및 AC 특성을 실험적으로 조사하였다. KEPCO HTS-cable system에서처럼 shield전류를 conductor와 크기는 같게 하고 방향을 반대로하여 수주기동안 AC pulse전류를 인가했을 때, shield의 임계전류가 conductor보다 작음에도 불구하고 conductor-lead에 대하여 측정된 AC loss가 shield의 것과 비교하여 약 1.5배 큰 것을 알 수 있었다

  • PDF