• Title/Summary/Keyword: Lead determination

Search Result 290, Processing Time 0.024 seconds

Studies on effects of calibration methods and current lead position on the direct current potential drop method for crack length measurement (직류전압강하법에 의한 균열길이 측정에 미치는 도선의 위치 및 보정방법의 영향에 관한 연구)

  • Cho, C.C.;Kim, I.S.;Kim, S.S.;Choe, S.J.;Hur, B.Y.
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.300-306
    • /
    • 1997
  • The effective resolution of the direct current potential drop (DCPD) method for crack length determination is strongly affected by a number of factors including wire locations and calibration method. In the present study, the effects of wire locations, thermal EMF and reference probe locations on the accuracy of calibration methods, including Hicks-Pickard equation and Johnson's equation, were examined with the CT specimens which were nine times larger than the standard specimen. In light of experimental results, it was found that Hicks-Pickard equation can accurately represent the a/W-V/Vo relationship when current input wire is located at the load line. It was also found that the accuracy of DCPD method can be greatly improved with the thermal EMF calibration and the use of Vo value at a/W = 0.241. The use of reference potential was found to be impractical when current input wire is located at the load line.

  • PDF

Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro (In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교)

  • Lee, In Hee;Kim, Yoo Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.306-312
    • /
    • 2015
  • The measurement of histamine is to determine the degree of allergy because the allergic reaction can lead to the release of histamine. In general, the antigen-antibody reaction was quantified by measuring absorbance using a microplate reader. In this study, we compare the method using a general antigen-antibody reaction and the method using a high performance liquid chromatography mass spectrometer (HPLC-MS) of chemical analysis in the measurement of histamine secretion. The cell line used was RBL-2H3, an allergic reaction was induced by stimulation with C48/80 (compound 48/80). Allergy-induced cells degranulation rate was confirmed by measurement of ${\beta}$-hexosaminidase and cytotoxicity was performed for the validity of the experiment. The quantitative determination of histamine showed a significant difference, since the quantitative limit of the measurement by the antigen-antibody reaction was 10.257 ppm while the quantitative limit of the measurement by HPLC-MS was 0.020 ppm. Measurement of histamine in allergic activity and anti-allergy tests showed that the HPLC-MS analysis rather than the analysis of the antigen-antibody reaction is a more precise and accurate test.

Development of a Method to Measure Hydrogen Sulfide in Wine Fermentation

  • Park, Seung-Kook
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.9
    • /
    • pp.1550-1554
    • /
    • 2008
  • A hydrogen sulfide $(H_2S)$ detecting tube was developed for the quantitative determination of $H_2S$ produced by yeast during laboratory scale wine fermentations. The detecting tube consisted of a small transparent plastic tube packed with an $H_2S$-sensitive color-indicating medium. The packed medium changed color, with the color change progressing upward from the bottom of the tube, upon exposure to $H_2S$ produced by yeast during fermentation. A calibration study using a standard $H_2S$ gas showed that the length of the portion that darkened was directly related to the quantity of $H_2S$ (${\mu}g$) with a high correlation coefficient ($r^2$=0.9997). The reproducibility of the $H_2S$ detecting tubes was determined with five repetitive measurements using a standard $H_2S$ solution [5.6${\mu}g$/200 ml (28 ppb)], which resulted in a coefficient of variation of 3.6% at this level of $H_2S$. With the sulfide detecting tubes, the production of $H_2S$ was continuously monitored and quantified from laboratory scale wine fermentations with different yeast strains and with the addition of different levels of elemental sulfur to the grape juice. This sulfide detecting tube technology may allow winemakers to quantitatively measure $H_2S$ produced under different fermentation conditions, which will eventually lead winemakers to better understand the specific factors and conditions for the excessive production of $H_2S$ during wine fermentation in a large production scale.

An Energy Efficient Data-Centric Probing Priority Determination Method for Mobile Sinks in Wireless Sensor Networks (무선 센서 네트워크에서 에너지 효율을 고려한 모바일 싱크의 데이터 중심 탐색 우선순위결정 기법)

  • Seong, Dong-Ook;Lee, Ji-Hee;Yeo, Myung-Ho;Yoo, Jae-Soo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.5
    • /
    • pp.561-565
    • /
    • 2010
  • Many methods have been researched to prolong sensor network lifetime using mobile technologies. In the mobile sink research, there are the track based methods and the anchor points based methods as representative operation methods for mobile sinks. However, the existing methods decrease Quality of Service (QoS) and lead the routing hotspot in the vicinity of the mobile sink. The reason is that they use static mobile paths that are not concerned about the network environments such as the query position and the data priority. In this paper, we propose the novel mobile sink operation method that solves the problems of the existing methods. In our method, the probing priority of the mobile sink is determined with the data priorities for increasing the QoS and the mobile features are used for reducing the routing hotspot. The experimental results show that the proposed method reduces query response time and improves network lifetime over the existing methods.

Evaluation of Machine Learning Algorithm Utilization for Lung Cancer Classification Based on Gene Expression Levels

  • Podolsky, Maxim D;Barchuk, Anton A;Kuznetcov, Vladimir I;Gusarova, Natalia F;Gaidukov, Vadim S;Tarakanov, Segrey A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.835-838
    • /
    • 2016
  • Background: Lung cancer remains one of the most common cancers in the world, both in terms of new cases (about 13% of total per year) and deaths (nearly one cancer death in five), because of the high case fatality. Errors in lung cancer type or malignant growth determination lead to degraded treatment efficacy, because anticancer strategy depends on tumor morphology. Materials and Methods: We have made an attempt to evaluate effectiveness of machine learning algorithms in the task of lung cancer classification based on gene expression levels. We processed four publicly available data sets. The Dana-Farber Cancer Institute data set contains 203 samples and the task was to classify four cancer types and sound tissue samples. With the University of Michigan data set of 96 samples, the task was to execute a binary classification of adenocarcinoma and non-neoplastic tissues. The University of Toronto data set contains 39 samples and the task was to detect recurrence, while with the Brigham and Women's Hospital data set of 181 samples it was to make a binary classification of malignant pleural mesothelioma and adenocarcinoma. We used the k-nearest neighbor algorithm (k=1, k=5, k=10), naive Bayes classifier with assumption of both a normal distribution of attributes and a distribution through histograms, support vector machine and C4.5 decision tree. Effectiveness of machine learning algorithms was evaluated with the Matthews correlation coefficient. Results: The support vector machine method showed best results among data sets from the Dana-Farber Cancer Institute and Brigham and Women's Hospital. All algorithms with the exception of the C4.5 decision tree showed maximum potential effectiveness in the University of Michigan data set. However, the C4.5 decision tree showed best results for the University of Toronto data set. Conclusions: Machine learning algorithms can be used for lung cancer morphology classification and similar tasks based on gene expression level evaluation.

The Change of Secretory Activity of the Alveolar Type ll Cell During Acute Alveolar Injury Induced by N-Nitroso-N-Methylurethane

  • Lee, Young-Man;Bang, In-Sook;Lee, Suck-Kang
    • The Korean Journal of Physiology
    • /
    • v.28 no.1
    • /
    • pp.71-77
    • /
    • 1994
  • In the animal model of acute respiratory distress syndrome (ARDS) induced by N-nitroso-N-methylurethane (NNNMU) the secretory activity of alveolar type H cells during acute alveolar injury was investigated by determining phospholipid and pulmonary surfactant associated proteins in crude surfactant. The mechanism of the secretory change was studied by determination of DNA and RNA levels in the lung tissue. After induction of acute alveolar injury with NNNMU, pulmonary hemorrhage, atelectasis and gross hypertrophy were observed. Seven days after NNNMU treatment the level of total DNA in lung homogenate was increased markedly indicating that a hypertrophy was induced by cellular proliferation. Although the total DNA level increased, the RNA/DNA ratio was gradually decreased after NNNMU treatment. Seven days after NNNMU treatment the RNA/DNA ratio returned to the normal control level. During the acute alveolar injury, phospholipid and surfactant associated proteins were reduced significantly as compared with the control, implying that the secretory activity of alveolar type II cells was altered during acute alveolar injury induced by NNNMU. The protein content in crude surfactant during peak injury(7 days after NNNMU) was decreased significantly but phospholipid/protein ratios were identical in both control and NNNMU treatment groups. SDS-PAGE of proteins in crude pulmonary surfactant showed a decrease in major surfactant associated protein(M.W. 38,000) during acute alveolar injury. The present study may suggest that while alveolar type H cells proliferate markedly, transcription of alveolar type ll cell gene was inhibited by an unknown mechanism such as DNA methylation induced by NNNMU. Such an inhibition of transcriptional activity is thought to be associated with the decreased secretory activity of alveolar type ll cells, which may lead to pulmonary atelectasis and edema during the acute alveolar injury.

  • PDF

A Study on the Radiopacity of Cavity Lining Materials for Posterior Composite Resin Restoration (구치부 복합레진 수복을 위한 와동 이장용 재료의 방사선투과성에 관한 연구)

  • Moon Joo-Hoon;Choi Eui-Rwan
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.243-248
    • /
    • 2000
  • Purpose: The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Plowable resin) for posterior composite resin restoration. Material & Methods: Resin-modified glass ionomer cement (Fuji II LC, Vitrebond/sup TM/), Compomers (Dyract /sup (R)/ Compoglass, F2,000, Dyract/sup (R)/ flow Compoglass Flow) and Flowable resins (Tetric/sup (R)/ flow, Aeliteflo/sup TM/ Revolution/sup TM/) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtainded from conventional radiograph and NIH image program. Results: All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract, Compoglass, F2,000, Dyract flow, Compoglass Flow) and Vitrebond/sup TM/, Tetric/sup (R)/ flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution/sup TM/ were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric/sup (R)/ flow were greater than those of Revolution/sup TM/, Aeliteflo/sup TM/ or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Conclusion: Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  • PDF

Development of an Axially Viewed Inductively Coupled Plasma for Atomic Emission Spectrometry and Comparison between the Detection Limits of Lead (원자방출 분광분석을 위한 수평형 유도결합 플라스마의 개발과 납 검출한계 비교)

  • Cho, Sung Il;Han, Myung Sub;Lee, Sang Hwa;Lee, Joung Hae;Woo, Jin Chun
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.6
    • /
    • pp.292-298
    • /
    • 1997
  • An ICP(Inductively Coupled Plasma) emission spectrometer was developed with an axially viewed ICP source incorporated by a 5-turned induction coil and a torch, outer quartz tube of which was 50 mm longer than that used in conventional ICP/AES(Inductively Coupled Plasma Atomic Emission Spectrometry). The Optimization of the system has been performed in terms of the determination of signal-to-noise ratio and background intensity at various rf powers, sample flow rates, argon gas flow rates and cut-off gas flow rates. The spectro-analytical characteristics of the spectrum obtained between 200 and 500 nm was revealed to be similar compared with a vertically viewed ICP source. The detection limit of Pb(Ⅱ) at 220.35 nm was 11 ppb which was 5 times lower than that obtained with a vertically viewed ICP source.

  • PDF

Determination of Consolidation Characteristics of Clayey Soils from the Self-boring Pressuremeter Test (자가굴착식 프레셔미터 시험을 이용한 점성토의 압밀특성 산정)

  • 장인성;정충기;김명모;조성민
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.87-96
    • /
    • 2002
  • The strain holding test(SHT) or the sell-boring pressuremeter test(SBPT) has been effectively utilized to determine the horizontal coefficient of consolidation$(c_h)$ of clayey soils. However, a commonly used procedure proposed by Clarke et al.(1979) can lead to an erroneous estimation of $(c_h)$ because of its simplified assumptions. This paper deals with numerical analyses based on realistic test conditions of the generally accepted testing procedure, and .using the most commonly used type of pressuremeter. The effects of pressuremeter geometry, partial drainage during cavity expansion, and the cavity strain level for the holding test are investigated with the radial distributions of the initial excess pore pressure and their dissipation rate. Based on the results of the numerical analyses, the curve of the time factor for the 50% degree of consolidation($T_{50}$) needed to estimate $(c_h)$ is proposed. Comparisons are made between $(c_h)$ values estimated from the SHT or the SBPT and those obtained from other in situ and laboratory tests performed at two sites in Korea. These results suggest the improved capability of the $T_{50}$ curve proposed herein.

Moisturization and Transdermal Penetration Characteristics of PEGimpregnated Aloe vera Gel from DIS Processing (DIS에 의한 Polyethylene Glycol 함침 알로에 베라 겔의 보습 및 경피흡수 특성)

  • Kwon, Hye Mi;Hur, Won;Lee, Shin Young
    • KSBB Journal
    • /
    • v.28 no.5
    • /
    • pp.319-326
    • /
    • 2013
  • This study was carried out to investigate the in vitro and in vivo moisturizing properties and percutaneous absorption of PEG-impregnated Aloe vera gel. The PEG-i-Aloe gel was obtained from dewatering and impregnation by soaking (DIS) of Aloe vera leaf slice. The moisturizing property of the obtained sample was evaluated by moisture determination using gravimetric method in desiccator under different RH% and by water sorption-desorption test on human skin. The transdermal penetration characteristics of PEG-i-Aloe gel was investigated by Franz diffusion cell in vitro transdermal absorption method. PEG-i-Aloe gel had high moisture retention ability and could significantly lead the enhancing skin hydration status as well as reducing the skin water loss due to the film formation as a skin barrier. The skin penetration rate of PEGi- Aloe gel at steady state was 9.76 ${\mu}g/(h{\cdot}cm^2)$ and the quantity of the transdermal absorption was 144 ${\mu}g/cm^2$ in 9 hr. The penetration mechanism was well fitted with Higuchi model ($R^2$ = 0.974-0.994). The results show that PEG-i-Aloe gel has the significant moisturizing effect and strong penetration of the animal skin. It could be used as the moisturizing additive in cosmetic skin products.