• Title/Summary/Keyword: Lead chromate

Search Result 15, Processing Time 0.022 seconds

Effect of Humic acid on the Distribution of the Contaminants with Black Shale (휴믹산이 black shale과 오염물질의 분포에 미치는 영향에 대한 연구)

  • Min, Jee-Eun;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.670-675
    • /
    • 2004
  • Humic acids are macromolecules originated from natural water, soil, and sediment. The characteristics of humic acid enable it to change the distribution of metals as well as many kinds of organic contaminants and to determine the sorption of them from soil solution. To see the effect of humic acid on the removal rate of organic contaminants and heavy metals, batch-scale experiments were performed. As a natural geosorbent, black shale was used as a sorbent media, which showed hight sorption capacity of trichloroethylene (TCE), lead, cadmium and chromium. The effect of sorption-desorption, pH, ionic strength and the concentration of humic acid was taken into consideration. TCE sorption capacity by black shale was compared to natural bentonite and hexadecyltrimethylammonium (HDTMA) modified bentonite. The removal rate was good and humic acid also sorbed onto black shale very well. The organic part of humic acid could effectively enhance the partition of TCE and it act as an electron donor to reduce Cr(VI) to Cr(III). Cationic metal of Pb(II) and Cd(II) also removed from the water by black shale. With 3 mg/L of humic acid, both Pb(II) and Cd(II) were removed more than without humic acid. That could be explained by sorption and complexation with humic acid and that was possible when humic acid could change the hydrophobicity and solubility of heavy metals. Humic acid exhibited desorption-resistivity with black shale, which implied that black shale could be an alternative sorbent or material for remediation of organic contaminants and heavy metals.

Case study of Hexavalent Chromium and Silica Exposure Assessment and Respiratory Fit-test for Paint Manufacturing Worker (페인트 제조 작업자의 6가 크롬 및 실리카 노출평가와 호흡보호구 밀착도 검사 사례)

  • Lee, Hyun Seok;Kim, Boowook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.295-303
    • /
    • 2021
  • Objective: Paint manufacturing industry workers are exposed to various lung cancer carcinogenic substances including hexavalent chromium and crystalline silica. Studies have been conducted on lung cancer in Paint manufacturing industry workers and the concentration of hexavalent chromium in paint industry; however, the concentration of crystalline silica and hexavalent chromium and cases of lung cancer in a single Paint factory has never been reported in Korea. Methods: To determine whether the cancer was related to his work environment, we assessed the level of exposure to carcinogens during pouring and mixing talc and pigment. In addition, a mask fit test was performed for the worker. Results: Analysis of talc and silica bulk powder materials showed that crystalline silica (quartz) was 5% in talc and 100% in silica. The green and yellow pigments contained 87% and 92% of lead chromate, respectively. Our quantitative analysis of pigment powder samples showed that the hexavalent chromium contents quantified in the green and yellow pigment samples were 87% and 92%, respectively. In order to estimate his exposure level of hexavalent chromium, we measured a personal exposure level of hexavalent chromium for a worker in accordance with the National Institute for Occupational Safety and Health #7605 method. The results showed that the worker was exposed to the high level of hexavalent chromium (0.033 mg m-3). In addition, the talc powder also contained 5% quartz, and the worker's exposure level to respirable quartz exceeded OEL. As a result of the respiratory protection fit test for workers, the overall Fit Factor was '15' when wearing a second-grade mask and '25' when wearing a first-grade mask, significantly lower than the US Occupational Safety and Health Agency (OSHA) pass value of "100". Conclusion: Workers who pouring and mixing powder materials such as talc or colored pigments in paint manufacturing company may be exposed to high concentrations of carcinogenic substances. These findings indicate that it is necessary to local ventilation system inspection, safety and health education for employers and workers, and periodically monitoring and manage the working environment.

The effects of chromium exposure on sister chromatid exchange and concentration of 8-hydroxydeoxyguanosine (크롬 폭로가 자매염색분체교환 빈도 및 8-hydroxydeoxyguanosine 농도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Kim, Heon;Ha, Mi-Na;Joo, Young-Soo;Park, Soo-Min;Kwon, Ho-Jang;Kim, Yong-Dae;Chung, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.511-525
    • /
    • 1995
  • To elucidate some DNA adducts as a biological marker for workers of chromate pigment, the effects of chromium exposure on the formation of 8-hydroxydeoxyguanosine(8-OH-dG) and sister chromatid exchanges(SCEs) frequency in 38 workers of a pigment plant in Bucheon which utilized lead chromates, were examined. The chromium contents of venous blood and urine were measured as working environmental exposure level. The concentrations of 8-OH-dG in DNA isolated from lymphocytes were determined with high performance liquid chromatography and electrochemical detector and denoted as a molar ratio of 8-OH-dG to deoxyguanosine(dG). The SCEs frequency were analyzed in DNA isolated from lymphocytes. A significant correlation was found between creatinine adjusted urine chromium concentration and the molar ratio of 8-OH-dG to dG(r=0.47, p<0.01). After adjusting the current smoking habit, the correlation coefficient was increased(r=0.62, p<0.05). However, there was no significant correlation between the SCE frequency and chromium exposure. This significant results between molar ratio of 8-OH-dG to dG and chromium exposure are in good agreement with in vitro studies that support the importance of DNA adduct formation for the carcinogenic effect of chromium.

  • PDF

Analysis of Paint Used for a Helicopter Operated in the Korean War through the History of Paint Application (페인트 도장의 역사를 통해 본 6·25전쟁 운용 헬기의 도료분석)

  • Kang Hyunsam;Jang Hanul;Choi Yangho
    • Conservation Science in Museum
    • /
    • v.29
    • /
    • pp.133-152
    • /
    • 2023
  • This study references preceding studies to examine the history of paint application techniques using various paints in the past, with the aim to contribute to the long-term preservation of large military cultural heritage assets situated outdoors. To this end, the study compared the findings of preceding research with the findings of an analysis conducted on a H-13 helicopter housed at the War Memorial of Korea. Upon collecting and analyzing samples from three grounded WWII aircraft from above-ground by preceding studies, it was confirmed from each sample that the various chemical properties of chrome ensured the effectiveness of the protective coating. The compound was first tested as a corrosion-inhibiting pigment in the early 1940s and proved its excellent moisture-resistant properties over the course of 80 years, despite the deterioration of the paint layer and long-term exposure to the natural environment. For this reason, it has been widely used as a corrosion inhibitor for aluminum alloys in the aviation industry. In other word, the most widely-used material for preventing corrosion was an organic primer containing chromate. In this study, based on the paint analysis of a H-13 helicopter operated in the Korean War, it was shown that the second layer, consisting of the primer, contains chromium oxide (Cr2O3). In addition, it was estimated that red lead tetraoxide (Pb3O4) was used for the vehicle. Analysis results and data from previous studies can help to confirm the continued effectiveness of corrosion prevention function provided by chromate. Meanwhile, the result of infrared spectroscopy analysis confirmed the use of alkyd resin. In the future, comparisons with a more diverse range of artifacts will allow the identification of changes in the manufacturing technology of paints used to protect alloys from corrosion.

Status of Industrial Environments of Some Industries in Taegu Kyungpook Area (대구지방 산업장에 있어서 건강장애요인과 작업환경검사에 대한 기업인의 수용태도 (ll))

  • Kim, Du-Hui;Seong, Su-Won
    • 월간산업보건
    • /
    • s.8
    • /
    • pp.4-30
    • /
    • 1988
  • Examination of working environments was conducted to get more detailed data about harmful working environments and to make a contribution to more effective management. Study was carried out on 722 factories located in Taegu city and eight counties in Kyungpook Province, Korea, for a period of one year, from February 1 to December 30, 1986. The total number and proportion of workers exposed to harmful material was 37,697, 45.2% among 83,368 workers. The results according to exposed material were as follows: 1. In the case of noise, proportion of exceeding the 8-hour TLV was 59%, Included were nail-cutting in assembly metal manufacturing industry and weaving process in textile. 2. Dust in mill process of coal manufacturing industries exceeded the TLV of second class of dust at all parts and exceeded the TLV at 6% as a whole.: 3. The fields of industry lower than 70 lux of illumination were storage equipment of food, auto-winder of textile, painting of wood wares and coal mixing, and 44% of all cases was lower than standard. 4. As a result of temperature index investigation(WBGT), about 12% of all sujects exceeded limit value. Included parts were rolling machine and reducing room. 5. In the case of organic solvents, TLV was exceeded at about 8%, The parts exceeded TLV according to materials belonged to this category were as follows. 1) Toluene: adhesive work in assembly metal manufacturing 2) Xylene: printing and paint mixing in chemical manufacturing 3) Methyl ethytl ketone: paint mixing in all parts examined and coating machine partially in chemical manufacturing 4) Methyl isobutyl ketone: printing in chemical manufacturing 5) Acetone: vapor polishing in assembly metal manufacturing 6. Among specified chemical materials, the concentration of HC1 in the air in metal assembly manufacturing factory exceeded TLV. in one of three assembly metal manufacturing examined. Others, such as benzene, acetic acid, formic acid, sodium hydroxide, formalin, ammonia, copper, chromate etc. were lower than TLV in its indoor atmospheric concentration. As a whole, the proportion of exceeding TLV was about 0.8% 7. The concentrations of inorganic lead were lower than TLV in all parts examined. The results of this investigation show the fact that current management of working environments is not satisfactory, and so more active management is needed.

  • PDF