• 제목/요약/키워드: Lead Battery

검색결과 271건 처리시간 0.026초

원전 비상전원 설계를 위한 납축전지 및 리튬계열전지 전기적 특성 비교 (Comparison of electrical characteristic between Lead-Acid Battery and Lithium-based Battery for Designing in NPPs)

  • 박성윤;김건우;김종훈;박성백
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.119-120
    • /
    • 2018
  • 국내 원자력 발전소의 비상전원공급을 위하여 대체교류디젤 발전기와 납축전지를 사용하고 있다. 납축전지는 온도, 방전 전류, 수명 및 안정성 등에서 리튬계열전지와 비교되고 있으며, 전기적 특성이 우수하고 안정성이 높은 리튬계열전지의 사용이 고려되고 있다. 본 논문은 원전의 비상전원 설계를 위하여 납축전지와 리튬계열전지의 전기적 특성을 비교 분석하였다.

  • PDF

연 노출 근로자들의 혈장 δ - aminolevulinic acid 량과 연 노출 지표들과의 관련성 (The Relationships between Plasma δ - aminolevulinic acid Concentration and Lead Exposure Indices in Lead Workers)

  • 김진호;안규동;이성수;황규윤;김용배;이병국
    • 한국산업보건학회지
    • /
    • 제10권2호
    • /
    • pp.165-172
    • /
    • 2000
  • This study was carried out to investigate relationship between plasma $\delta$ - aminolevulinic acid (ALAP) and lead exposure indices in exposure to lead. The subjects were 218 male workers in 2 storage battery companies and 2 secondary smelting companies. Blood lead(PbB), blood zinc-protoporphyrin( ZPP), urinary $\delta$ - aminolevulinic acid (ALAU), hemoglobin(Hb), and hematocrit(Hct) were measured as lead exposure indices. The results were as follows, 1. The means of blood lead and blood ZPP concentration of subjects were $27.2{\pm}14.0{\mu}g/d{\ell}$ and $55.1{\pm}47.6{\mu}g/d{\ell}$, respectively. The means of plasma $\delta$ - ALA and urinary $\delta$ - ALA concentration were $18.9{\pm}25.1{\mu}g/d{\ell}$ and $2.1{\pm}4.6mg/{\ell}$, respectively. 2. The concentration of ALAP was $11.2{\mu}g/{\ell}$ for below $20{\mu}g/d{\ell}$ PbB, $12.8{\mu}g/{\ell}$ for from $21-40{\mu}g/d{\ell}$ PbB, and $51.2{\mu}g/{\ell}$ for over $40{\mu}g/d{\ell}$ PbB, respectively. 3. ALAP was significantly correlated with ALAU(r=0.829, p<0.01), ZPP(r=0.724, p<0.01) and PbB(r=0.552, p<0.01).

  • PDF

연작업자들에서 골중 연량이 신경행동학적 검사성적에 미치는 영향 (Association of Bone Lead with Neurobehavioral Test Scores in Lead Workers)

  • 이성수;김남수;김화성;안규동;이병국
    • 한국산업보건학회지
    • /
    • 제15권2호
    • /
    • pp.144-152
    • /
    • 2005
  • To evaluate the effect of lead biomarkers including bone lead on neurobehavioral test in lead workers, 652 lead workers without any occupational exposure to organic solvent, mercury and arsenic were agreed to participate this study. For the control subjects 102 non-occupationally lead exposed blue collar workers in general manufacturing industries were also joined this study. All study subjects joined this study with written informed consent. The study variables of lead exposure were blood and patella lead. For the general characteristics of study subjects, standardized questionnaire regarding age, sex, past disease history, job duration, body mass index (BMI), drinking and smoking habit were provided. For the past history of neurotoxicity related diseases, all study subjects were interviewed by qualified occupational health physician. The results obtained were as follows: 1. Compared with controls without occupational lead exposure, lead exposed subjects had worse performance on all tests(p<0.05). 2. After adjustment for covariates (age, sex, job duration, education level, BMI, smoking and drinking status), the signs of the regression coefficients for blood lead were negative for 13 of the 14 tests. Blood lead was a significant predictor of poorer scores on 8 tests (simple reaction time(ms & root MSD), Trail-Making Test B, Digit Symbol Substitution, Purdue Pegboard assembly, Digit Span Test, Benton Visual Retention, and Purdue pegboard both hand). 3. After adjustment for covariates (age, sex, job duration, education level, BMI, smoking and drinking status), the signs of the regression coefficients for patella lead were negative for 12 of the 14 tests. Patella lead was a significant predictor of poorer scores on 8 tests (simple reaction time(ms). Purdue Pegboard assembly, Digit Span Test, Benton Visual Retention. Pursuit Aiming rest (no. of correct & no. of incorrect), Purdue pegboard non-dominant hand and both hand). With above results, blood lead and patella lead were associated with poorer performance of neurobehavioral tests. In addition, patella lead was confirmed to be better predictor of manual dexterity test in neurobehavioral test battery in lead workers

배터리 리드탭 압흔 오류 검출의 딥러닝 기법 적용 (Application of deep learning technique for battery lead tab welding error detection)

  • 김윤호;김병만
    • 한국산업정보학회논문지
    • /
    • 제27권2호
    • /
    • pp.71-82
    • /
    • 2022
  • 자동차용 배터리 제조공정 가운데 하나인 Tab Welding 공정에서 생산된 제품의 샘플링 인장검사를 대체하기 위해 현재 비전검사기를 개발하여 사용하고 있다. 그러나, 비전검사는 검사 위치 오차 문제와 이를 개선하기 위해 발생하는 비용 문제를 가지고 있다. 이러한 문제점들을 해결하기 위해 최근 딥러닝 기술을 적용하는 사례들이 발생하고 있다. 본 논문도 그런 사례 중 하나로 기존 제품 검사에 딥러닝 기술 중 하나인 Faster R-CNN을 적용하여 그 유용성을 파악하고자 하였다. 기존 비전검사기를 통해 획득한 이미지들을 학습 데이터로 사용하여 Faster R-CNN ResNet101 V1 1024x1024 모델을 사용하여 학습하였다. 검사 기준인 미검률 0%, 과검률 10%의 기준으로 기존 비전검사와 Faster R-CNN 검사결과를 비교 분석하였다. 미검출률은 기존 비전검사에서 34.5%, Faster R-CNN 검사에서 0%였다. 과검출률은 기존 비전검사에서 100%, Faster R-CNN에서 6.9%였다. 결론적으로 자동차용 배터리 리드탭 암흔 오류 검출에 딥러닝 기술이 매우 유용함을 확인할 수 있었다.

전기자동차용 리튬이온 전지의 제조공정을 위해 개선된 극판 건조 기술 (Improved Drying Process for Electrodes in Production of Lithium-Ion Batteries for Electric Vehicles)

  • 장찬희;이재천
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.37-45
    • /
    • 2018
  • 전기자동차는 내연기관 자동차와는 달리 배출가스가 없어 친환경 차량을 대표하지만, 장착된 축전지에 충전된 전기로 구동되기 때문에, 1회 충전으로 갈 수 있는 거리가 전지의 에너지 밀도에 의해 좌우된다. 따라서 높은 에너지 밀도를 갖는 리튬이온 배터리가 전기구동자동차용 전지로 많이 사용하고 있다. 리튬이온 배터리의 효율을 지배하는 중요한 구성품은 전극이므로 전극 제조공정은 리튬이온 배터리 전체생산 공정에서 중요한 역할을 한다. 특히 전극의 제조 공정 중 건조공정은 성능에 큰 영향을 미치는 매우 중요한 공정이다. 본 논문에서는 전극제조에서 건조공법의 효율성 및 생산성 증대를 위한 혁신적인 공정을 제안하고, 장비 설계 방법 및 개발 결과에 대하여 기술하였다. 구체적으로, 극판 결착력 향상 기술, 대기압 과열증기 건조 기술, 그리고 건조로 폭 슬림화 기술들에 대한 설계 절차 및 개발방법을 제시하였다. 결과로 세계최초의 개방형/일체형 대기압 과열증기 Turbo Dryer 양산기술 확보를 통해 전기차 전지용 극판 고속건조기술을 확보 하였다. 기존의 건조공정과 비교할 때 건조로 길이 생산성을 향상시켰다 (건조 Lead Time 0.7분(分) ${\rightarrow}$ 0.5분(分)기준).

연 노출 근로자들의 ALAD genotype에 따른 연 노출지표 및 증상과의 관련성 (Relationship on the lead exposure indices and symptoms by ALAD genotype in lead worker)

  • 안규동;이종천;조광성;김진호;이성수;이병국
    • 한국산업보건학회지
    • /
    • 제11권2호
    • /
    • pp.111-117
    • /
    • 2001
  • A cross-sectional study was performed to evaluate associations between lead biomarkers, lead-related symptoms, and ${\delta}$-aminolevulinic acid dehydratase (ALAD) genotype among 598 lead workers and 144 control office workers in storage battery industries, secondary smelting and litharge making industries. Lead inhibits the second enzymes, ALAD, in the heme synthesis pathway. ALAD gene, which codes for one of three isozymic proteins (termed ALAD1-1, ALAD1-2, and ALAD2-2), seems to modify the toxicokinetics of lead. The result as follows; The percents of total workers whose genotype of ALAD1-1 and ALAD1-2 were 88.4% and 11.6%, respectively. The zinc protoporphyrin in blood (ZPP) and ${\delta}$-aminolevulinic acid in urine (ALAU) of lead workers with ALAD1-2 were significantly lower than those of lead workers with ALAD1-1, but there were no significant difference between two genotype for blood lead, age, and work duration. The proportion of ALAD1-2 genotype in control office workers was 13.2%. The proportions of ALAD1-2 genotype of lead workers were 14.0%(their mean air lead level below $0.024mg/m^3$), 10.4%($0.025-0.049mg/m^3$), 11.8%($0.050-0.099mg/m^3$), and 9.4%(above $0.100mg/m^3$), respectively. In the logistic analysis of 15 lead related symptoms, 'arthralgia'(S7) symptom of ALAD1-2 was significantly lower (OR=0.481; 95% CI=0.248-0.932) than that of ALAD1-1, but 'feeling of irritation'(S11) of ALAD1-2 was significantly higher(OR=1.636; 95% CI=1.035-2.586) than that of ALAD1-1 after controlling possible confounder (blood lead, work duration, smoking and drinking habit).

  • PDF

철도차량용 축전지 적용 사례 (Cases of applying battery to rolling stock)

  • 김상웅;김신국;안홍관;김재기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.413-422
    • /
    • 2011
  • 축전지는 차량을 기동할 때나 비상시의 제어전원으로서 철도차량의 구성품 중 매우 중요한 부분이다. 현재 널리 사용되고 있는 축전지로는 연축전지와 니켈카드뮴축전지 등이 있으며 점차 소형화 경량화 되어 가고 있는 추세이다. 또한 철도차량의 전자제어기술의 발달로 인하여 필요로 하는 전기용량이 늘어나고 있다. 따라서 다양한 종류의 고효율 축전지들이 신규 노선의 차량에 검토되고 있지만 철도차량용 축전지는 안전상으로 충분히 검증이 되어야 하며 또한 관리 측면에서도 어려움이 없어야 하는 요구조건으로 인하여 실제 적용하는 데에는 많은 어려움이 있다. 본 논문에서는 현재 철도차량에 적용된 축전지 사례를 조사하고 적용을 시도 중인 축전지들의 특성을 확인하여 안전 및 성능, 관리적인 측면에서 어떠한 문제가 있는지 검토하여 향후 축전지 발전 동향에 대하여 논하고자 한다.

  • PDF

전력소비자 수요관리용 전지전력저장시스템의 적정 가격 산정 (Estimation of Reasonable Price of Battery Energy Storage System for Electricity Customers Demand Management)

  • 김슬기;조경희;김종율;김응상
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1390-1396
    • /
    • 2013
  • The paper estimated the reasonable market price of lead-acid battery energy storage system (BESS) intended for demand management of electricity customers. As time-of-use (TOU) tariffs have extended to a larger number of customers and gaps in the peak and off-peak rates have gradually risen, deployment of BESS has been highly needed. However, immature engineering techniques, lack of field experiences and high initial investment cost have been barriers to opening up ESS markets. This paper assessed electricity cost that BESS operation could save for customers and, based on the possible cost savings, estimated reasonable prices at which BESSs could become a more prospective option for demand management of customers. Battery scheduling was optimized to maximize the electricity cost savings that BESS would possibly achieve under TOU tariffs conditions. Basic economic factors such as payback period and return on investment were calculated to determine reasonable market prices. Actual load data of 12 industrial customers were used for case studies.

박막 전지용 Pt 도핑 비정질 산화바나듐의 구조적 변화 (Structure Evolution of Pt doped Amorphous ${V_2}{O_5}$Cathode Film for Thin Film Battery)

  • 김한기;전은정;옥영우;성태연;조원일;윤영수
    • 한국전기전자재료학회논문지
    • /
    • 제13권9호
    • /
    • pp.751-757
    • /
    • 2000
  • The r.f. power effect for Pt doping is investigated on structural and electrochemical properties of amorphous vanadium oxide(V$_2$O$_{5}$) film, grown by direct current (d.c.) magnetron sputtering. Room temperature charge-discharge measurements based on a half-cell with a constant current clearly indicated that the Pt doping could improve the cyclibility of V$_2$O$_{5}$ cathode film. Using glancing angle x-ray diffraction(GXRD) and high-resolution transmission electron microscopy (HRTEM) analysis, we found that the Pt doping with 10W r.f. power induces more random amorphous structure than undoped V$_2$O$_{5}$ film. As the r.f. power of Pt target increases. large amount of Pt atoms incorporates into the amorphous V$_2$O$_{5}$ film and makes $\alpha$-PtO$_2$microcrystalline phase in the amorphous V$_2$O$_{5}$ matrix. These results suggest that the semiconducting $\alpha$-PtO$_2$ microcrystalline phase in amorphous matrix lead to a drastically faded cyclibility of 50W Pt doped V$_2$O$_{5}$ cathode film. Possible explanations are given to describe the Pt doping effect on cyclibillity of the amorphous V$_2$O$_{5}$ cathode film battery. film battery.

  • PDF

디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구 (Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator)

  • 조종민;안현성;김지찬;차한주
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.