• Title/Summary/Keyword: Lateral-type

Search Result 1,270, Processing Time 0.025 seconds

Correlation Between Lateral Photovoltaic Effect and Conductivity in p-type Silicon Substrates

  • Lee, Seung-Hoon;Shin, Muncheol;Hwang, Seongpil;Park, Sung Heum;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1845-1847
    • /
    • 2013
  • The lateral photovoltaic effect (LPE) can be observed in semiconductors by irradiating a light spot position between electrodes on sample's surface. Because lateral photovoltaic voltage (LPV) is sensitively changed by light spot position, a LPE device has been tried as a position-sensitive detector. This study discusses the correlation between LPV and conductivity in p-type silicon and nano-structured Au deposited p-type silicon (nano-Au silicon), respectively. Conductivity measurement of the sample was carried out using the four-wire method to eliminate contact resistance, and conductivity dependence on LPV was simultaneously measured by changing the light irradiation position. The result showed a strong correlation between conductivity and LPV in the p-type silicon sample. The correlation coefficient was 0.87. The correlation coefficient between LPV and conductivity for the nano-Au silicon sample was 0.41.

평면전극구조를 갖는 바이올로진 기반의 일체형 전기변색소자 (Viologen-based All-in-one Electrochromic Devices with a Lateral Electrode Structure)

  • 김현정;이상래;최진희;나윤채
    • 한국분말재료학회지
    • /
    • 제27권1호
    • /
    • pp.58-62
    • /
    • 2020
  • Recently, electrochromic devices (ECDs) have gathered increasing attention owing to their high color contrast and memory effect, which make them highly applicable to smart windows, auto-dimming mirrors, sensors, etc. Traditional ECDs have a sandwich structure that contains an electrochromic layer between two ITO substrates. These sandwich-type devices are usually fabricated through the lamination of two electrodes and followed by the injection of a liquid electrolyte in the inner space. However, this process is sometimes complex and time consuming. In this study, we fabricated ECDs with a lateral electrode structure that uses only an ITO substrate and an all-in-one electrochromic gel, which is a mixture of electrolyte and electrochromic material. Furthermore, we investigated the EC properties of the lateral-type device by comparing it with a sandwich-type device. The lateral-type ECD shows strong blue absorption as the applied voltage increases and has a competitive coloration efficiency compared to the sandwich-type device.

기둥식 벽체 거푸집 시스템 개발에 관한 실험적 연구 (An Experimental Study on the Development of Unit Column Wall Form System Using (Focusing on the Lateral Pressure))

  • 강창수;이한승;태성호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.507-510
    • /
    • 2005
  • Euro form which constructs the present RC structures is used widely by the form method of construction of a wall type structure had much consumption of the human power and equipments by the assembly and the demolition, and the complement was required according to demerit with much leakage of cement paste by the form joint, so it developed the new pillar type form system. On the study, in order to consider the modification characteristic by lateral pressure which does the influence most important for the new developed pillar type form system performance, research of a paper manufactured a miniature wall form model, and advanced performance evaluation focusing on lateral pressure. Moreover, lateral pressure evaluation of a new style system was actually gone on through the on-site experiment about a part of wall type srutcture spot for a model experiment and its result on the foundation which is the purpose in evaluating on-site application possibility propriety at the foundation time of wall type concrete structure construction of a pillar type form system.

  • PDF

족관절 외과의 Danis-Weber B형 단독 골절에 있어서 활주 방지 금속판고정술과 외측 금속판고정술의 비교 (Comparison of Antiglide Plate Fixation and Lateral Plate Fixation for Danis-Weber Type B Isolated Lateral Malleolar Fractures)

  • 하중원;김형복;고민석;윤한국
    • 대한족부족관절학회지
    • /
    • 제15권3호
    • /
    • pp.153-158
    • /
    • 2011
  • Purpose: This study was performed retrospectively and to compare the clinical outcomes of the surgical management using Antiglide plating and lateral plating for Danis-Weber type B isolated lateral malleolar fractures. Materials and Methods: Between March 2004 and March 2009, 92 patients were followed up for more than 6 months after surgical treatment. 49 patients were treated with Antiglide plating, whereas the remaining 43 patients underwent lateral plating. The results of the two groups were analyzed both radiographically and clinically using Ankle scoring system. Results: Both groups were comparable for age, sex distribution, time to surgery, and operation time. Bone union was noted at average of 8 weeks in all fractures. The mean ankle score was similar in both groups (94% versus 93%). Conclusion: Antiglide plating for Danis-Weber type B isolated lateral malleolar fracture is one of the good methods which has some advantages such as early ankle motion, ambulation and smaller operative incision.

실물모형 시험를 이용한 U형 강박스거더의 상부 수평브레이싱에 관한 실험적 연구: 비틂강성 (Experimental Study on the Top- Lateral Bracing of U-Type Steel Box Girders Using Real Size Specimen: Torsional Stiffness)

  • 심낙훈;박영석
    • 한국강구조학회 논문집
    • /
    • 제18권4호
    • /
    • pp.447-456
    • /
    • 2006
  • 본 논문에서는 실내실험을 통하여 U형 강박스거더의 상부 수평브레이싱이 비틂거동에 미치는 영향을 파악하고 기존의 제안식에 대한 적정성을 검토하기 위하여, 실제 시공되고 있는 U형 강박스거더 단면 크기의 2/3 정도 되는 캔틸레버보 형식의 시험체를 제작하여 상부 수평브레이싱의 형태 및 패널 간격에 따른 비틂강성의 효과를 파악하였다. 그 결과, 상부 수평브레이싱을 설치함으로써 거더의 비틂강성이 상당히 증가함을 알 수 있었으며, 브레이싱의 패널 구성을 가장 경제적으로 설계하기 위해서는 폭과 길이의 비가 약 1:1.5 즉, 대각선브레이싱과 상부 플랜지의 경사 예각이 약 $40^{\circ}$로 설치하는 것이 바람직할 것으로 판단되었다.

Danis-Weber B형 족관절 외과 골절의 고정방법 비교연구 : Antiglide 금속판 고정술 대 외측 금속판 고정술 (Comparative Study for the Fixation Method in the Danis-Weber Type B Lateral Malleolar Fractures: An Antiglide Plate Fixation versus A Lateral Plate Fixation)

  • 신헌규;최재열;강동호
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.201-206
    • /
    • 2006
  • Purpose: To evaluate the advantages of the antiglide plate fixation procedure for Danis-Weber type B lateral malleolar fractures of ankle compared to other methods of lateral plate fixation. Materials and Methods: We reviewed 70 cases that antiglide plate fixation and lateral plate fixation procedures were performed from Mar. 2001 through Mar. 2006. Of the total 70 cases, they were divided into two groups ; 22 cases were treated with the antiglide plate procedure (Group I) and 48 cases were treated with the lateral plate procedure (Group II). The results of the two groups were analyzed both radiographically and clinically using Ankle-Hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS). Results: All fractures were healed at average of 8 weeks both radiographically and clinically. According to the Ankle-Hindfoot scale, all cases of Group I and 48 cases of Group II were above 80 points. 2 cases (9%) in Group I complained of peroneal tendinitis, while 19 cases (39%) in Group II showed skin irritation resulting from the screw or the plate. A total of 6 cases (27%) in Group I and 27 cases (55%) in Group II complained cosmetic problems. Conclusion: we concluded that the antiglide plate fixation for Danis-Weber type B lateral malleolar fractures is one of the good methods. But, further analysis will be need to find a solution for the peroneal tendinitis.

  • PDF

Lateral arthroplasty along with buccal fat pad inter-positioning in the management of Sawhney type III temporomandibular joint ankylosis

  • Malhotra, Vijay Laxmy;Singh, Virendra;Rao, JK Dayashankara;Yadav, Sunil;Gupta, Pranav;Shyam, Radhey;Kirti, Shruti
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권3호
    • /
    • pp.129-134
    • /
    • 2019
  • Objectives: The objective of this study was to highlight the role of lateral arthroplasty along with interposition of the buccal fat pad (BFP) in the management of Sawhney type III temporomandibular joint (TMJ) ankylosis. Materials and Methods: Ten patients with TMJ ankylosis (7 unilateral and 3 bilateral, total of 13 joints) were treated with lateral arthroplasty and BFP interposition. The bony bridge of the ankylotic mass on the lateral aspect was resected, leaving a distance of 1.5 to 2.0 cm from the base of the skull to the neck of the condyle. The condyle was left intact. Coronoidectomy was performed on the ipsilateral side via the same approach in all cases. The inter-incisal opening was measured at that time, and if it was less than 35 mm, contralateral coronoidectomy was performed by using the intra-oral approach. After satisfactory inter-incisal mouth opening (${\geq}35mm$) was achieved, the TMJ surgical site was revisited, and BFP was retrieved and used to cover the lateral aspect of the medially placed condyle. Results: With lateral arthroplasty, the medially displaced condyle can be left in-situ to maintain the mandibular ramal height and function and to act as a growth center in children. Interposition of the BFP prevents reformation of the lateral bony bridge that was removed. Conclusion: Lateral arthroplasty along with interpositioning of the BFP is a novel technique for managing Sawhney type III ankylosis that achieves management goals while avoiding complex and advanced reconstructive surgical procedures.

5종 골내 임플란트의 구조에 따른 주위의 응력분산에 관한 광탄성학적 연구 (A PHOTOELASTIC ANALYSIS OF STRESS DISTRIBUTIONS AROUND FIVE DIFFERENT TYPES OF ENDOSSEOUS IMPLANTS ACCORDING TO THEIR STRUCTURES)

  • 이정남;조성암
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.643-659
    • /
    • 1993
  • This study was performed for the purpose of evaluating the stress distributions around five different types of implants according to their structures. The stress distribution around the surrounding bone was analysed by two-dimensional photoelastic method. Five epoxy resin models were made, and vertical and lateral forces were applied to the models. A circular polariscope was used to record the isochromatic fringes. The results of this study were summerized as follows : 1. Threaded type implants showed more even stress distribution patterns than cylinderical type implants when vertical and lateral forces were applied. 2. The stress concentrated patterns were observed at the neck portion and middle portion of the cylindrical type implants comparing with threaded type implants when vertical force was applied. 3. Model 1 and model 4 which are tthreaded type implants showed similar stress distribution patterns at the middle and apical portions and more stress was concentrated at the neck porion of model 1 comparing with model 4 when vertical force was applied. The stresses around model 1 were more evenly distributed when lateral force was applied. 4. More stress was concentrated at the neck and middle portion of cylindrical type implants than threaded type implants when lateral force was applied. 5. Model 1 showed the most even stress distribution patterns when lateral force was applied and stress distribution did no occured at the apical portion of modedl 2 when lateral force was applied. 6. There were almost no differences in stress concentrated patterns with or without having hollow design. And the stress concentrated patterns were observed at the corner of apex in model 5 which has hollow design when vertical force was applied.

  • PDF

DCM 타설 지반에 관한 실내모형실험 (Experimental Study on Soft Ground with DCM Column)

  • 홍기권
    • 한국지반신소재학회논문집
    • /
    • 제19권3호
    • /
    • pp.35-44
    • /
    • 2020
  • 본 연구에서는 연약지반에 설치된 DCM 개량체의 개량효과를 개량형식에 따라 정량적으로 비교하기 위하여 일련의 실내모형 실험을 수행하였다. 즉, 무보강 및 3종류의 DCM 개량체 형식에 대한 상재하중 재하에 따른 지반 거동을 재현하고, 지반의 침하량 및 측방변위량을 분석함으로써 DCM 개량형식에 따른 연약지반의 거동을 평가하였다. 먼저, 모형지반에 대한 성토하중 재하시험 결과 무보강의 경우에는 작은 하중 증가에도 침하가 급격히 발생한 반면에, DCM 개량체가 적용된 경우에는 상대적으로 적은 침하가 발생하였다. 그리고 상재하중 증가에 따른 지반의 측방유동 거동을 분석한 결과, 무보강의 경우에는 작은 하중 증가에도 불구하고 측방변위가 크게 발생되었다. 그러나 DCM 개량체가 적용된 경우에는 상대적으로 적은 측방유동이 발생되었으며, 동일한 하중조건에 대한 측방유동 발생량의 크기는 말뚝식, 벽식, 격자식의 순으로 나타남을 확인하였다. 따라서 격자식 DCM 개량체가 적용된 경우가 측방유동에 대하여 우수한 지반개량효과를 나타낸 것으로 평가되었다.

Uniaxial Compression Behavior of High-Strength Concrete Confined by Low-Volumetric Ratio Lateral Ties

  • Hong Ki-Nam;Han Sang-Hoon
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.843-852
    • /
    • 2005
  • Presently, test results and stress-strain models for poorly confined high-strength columns, more specifically for columns with a tie volumetric ratio smaller than $2.0\%$, are scarce. This paper presents test results loaded in axial direction for square reinforced concrete columns confined by various volumetric ratio lateral ties including low-volumetric ratio. Test variables include concrete compressive strength, tie yield strength, tie arrangement type, and tie volumetric ratio. Local strains measured using strain gages bonded to an acryl rod. For square RC columns confined by lateral ties, the confinement effect was efficiently improved by changing tie arrangement type from Type-A to Type-B. A method to compute the stress in lateral ties at the concrete peak strength and a new stress-strain model for the confined concrete are proposed. Over a wide range of confinement parameters, the model shows good agreement with stress-strain relationships established experimentally.