• 제목/요약/키워드: Lateral resolution.

검색결과 168건 처리시간 0.026초

Extended SBM 공정을 이용하여 단일 실리콘 기판상에 제작된 새로운 z 축 가속도계 (A Novel z-axis Accelerometer Fabricated on a Single Silicon Substrate Using the Extended SBM Process)

  • 고형호;김종팔;박상준;곽동훈;송태용;조동일;허건수;박장현
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.101-109
    • /
    • 2004
  • This paper presents a novel z-axis accelerometer with perfectly aligned vertical combs fabricated using the extended sacrificial bulk micromachining (extended SBM) process. The z-axis accelerometer is fabricated using only one (111) SOI wafer and two photo masks without wafer bonding or CMP processes as used by other research efforts that involve vertical combs. In our process, there is no misalignment in lateral gap between the upper and lower comb electrodes, because all critical dimensions including lateral gaps are defined using only one mask. The fabricated accelerometer has the structure thickness of $30{\mu}m$, the vertical offset of $12{\mu}m$, and lateral gap between electrodes of $4{\mu}m$. Torsional springs and asymmetric proof mass produce a vertical displacement when an external z-axis acceleration is applied, and capacitance change due to the vertical displacement of the comb is detected by charge-to-voltage converter. The signal-to-noise ratio of the modulated and demodulated output signal is 80 dB and 76.5 dB, respectively. The noise equivalent input acceleration resolution of the modulated and demodulated output signal is calculated to be $500{\mu}g$ and $748{\mu}g$. The scale factor and linearity of the accelerometer are measured to be 1.1 mV/g and 1.18% FSO, respectively.

High Resolution Transmission Electron Microscopy Observations on Sintering Processes in KNbO3 Ceramics

  • Lee, Hwack Joo;Kim, Young Heon;Ryu, Hyun;Cho, Yang-Koo;Nahm, Sahn
    • Applied Microscopy
    • /
    • 제47권3호
    • /
    • pp.203-207
    • /
    • 2017
  • A homogeneous $KNbO_3$ (KN) phase was formed by sintering at $1,040^{\circ}C$ for 1 hour, without formation of the $K_2O$-deficient secondary phase even though suffering the minor loss of $K_2O$. KN liquid phase was formed during sintering and abnormal grain growth occurred in this specimen. The detailed microstructural observations on KN during sintering were carried out using high resolution transmission electron microscopy. The ledged structures were found at the KN grain boundary and the abnormal grain growth was performed by the lateral migration of these ledges in the presence of the liquid phase. The liquid pockets were found in the KN grains. They have various external shapes mainly due to the kinetic factors. They have atomically flat interfaces with some ledges with one atomic height. The slight deficient $K_2O$ by evaporation might somewhat reduce the melting point of KN from the reported at $1,058^{\circ}C$. The liquid pockets play an important role in supplying the liquid phase during the abnormal grain growth in the sintering process of KN ceramics.

피부학(Dermatology)을 위한 고해상도 초음파 진단 장치에 관한 연구 (A study of the high resolution Ultrasound Diagnostic system for Dermatology)

  • 류점수;임춘성;김영길
    • 전자공학회논문지S
    • /
    • 제35S권6호
    • /
    • pp.66-71
    • /
    • 1998
  • 본 연구에서 피부계통의 진단에 이용될 수 있는 고해상도 영상진단기를 개발하였으며 개발된 영상진단기는 sector scanning 방식으로서 A-mode, B-mode, M-mode의 80${\mu}m$ 축방향, 250${\mu}m$ 축방향 해상도로 $5mm {\times} 5mm$의 인체 단면 영상을 초당 20frame으로 나타낸다. 이 영상장치는 대부분의 피부학(dermatology) 계통의 질환에 그 병리학적인 연구에 이용될 수 있을 뿐만 아니라 안과(ophthalmology)나 치과(odontology) 계통의 병리학적인 판단에도 도움을 줄 수 있다고 생각되며 또한 피부미용(dermato-cosmetology)을 위한 분야에도 응용 가능하다.

  • PDF

Triamcinolone Acetonide 주사를 이용한 족관절 외과 점액낭염의 치료 (Triamcinolone Acetonide Injections for Lateral Malleolar Bursitis of the Ankle)

  • 우승훈;김정신;손승민;신원철
    • 대한족부족관절학회지
    • /
    • 제23권1호
    • /
    • pp.12-17
    • /
    • 2019
  • Purpose: This study examined the clinical outcomes and usefulness of triamcinolone acetonide (TA) injections as an option in the conservative treatment of patients with lateral malleolar bursitis of the ankle. Materials and Methods: A total of 27 patients (27 ankles), in whom TA injection had been performed between March 2016 and June 2017, were reviewed retrospectively. After the aspiration of fluid in the lateral malleolar bursal sac, 1 mL (40 mg) of TA was injected into the malleolar bursal sac. After the injection, the ankle was compressed with an elastic cohesive bandage for 2 to 4 weeks. The clinical outcomes and side effects were evaluated at the following time points: 2 weeks, 4 weeks, 3 months, 6 months, and 1 year after TA injection therapy. The responses to treatment were assessed according to the degree of fluctuation, shrinkage of the bursal sac, and soft tissue swelling. Results: The mean age was 62.1 years (range, 41~81 years); there were 19 males and 8 females. Complete resolution was observed in 26 patients (96.3%) after the first or second application of a TA injection, and a partial response was observed in 1 patient (3.7%) after the first TA injection. The physical component scores of Medical Outcomes Study 36-item Short-Form Health Survey improved from 71.1 to 76.0 at the last follow-up (p=0.001). Associated complications were 1 patient (3.7%) with skin atrophy and 3 patients (11.1%) with transient hyperglycemia in diabetes mellitus. Conclusion: TA injection is a useful and safe procedure for patients not responding to the usual conservative treatment of lateral malleolar bursitis of the ankle.

특허맵과 AHP를 활용한 최적의 LCD 저온폴리실리콘 결정화 기술 선정 (Determining an Optimal Low Temperature Polycrystalline Silicon Crystallization Technology of LCD using Patent Map and AHP)

  • 김관열;이장희
    • 지식경영연구
    • /
    • 제12권1호
    • /
    • pp.39-52
    • /
    • 2011
  • Many LCD manufacturers continue to develop the technologies of LCD manufacturing processes for the reduction of production cost, power consumption and high-resolution. The LTPS (Low Temperature Polycrystalline Silicon) crystallization technology is important for rearranging the internal structure of liquid crystal grain by adding certain energy to amorphous silicon and turning it into poly-silicon in order to manufacture LCD with better performance. We consider 14 existing technologies of LTPS crystallization in the LCD manufacturing and present an intelligent analysis methodology using patent map and AHP (Analytic Hierarchy Process) analysis for determining an optimal LTPS crystallization technology. By using patent map analysis, we easily understand the development process and mega-trend of LTPS crystallization technologies and their relationship. By using AHP analysis, we evaluate 14 LTPS technologies. Through the use of proposed methodology, we determine the Continuous Wave Laser Lateral Crystallization technology as an optimal one.

  • PDF

Spontaneous Pneumocephalus Caused by Pneumococcal Meningitis

  • Kim, Hyun Sook;Kim, Seok Won;Kim, Sung Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권4호
    • /
    • pp.249-251
    • /
    • 2013
  • Pneumocephalus is a condition characterized by the presence of air in the cranium, and it is mainly caused by trauma or a neurosurgical procedure. In the absence of head trauma or a neurosurgical procedure, meningitis is an extremely rare cause of pneumocephalus. Here, the authors present a rare case of spontaneous pneumocephalus caused by pneumococcal meningitis, in which simple lateral radiography and computed tomography (CT) findings of the skull suggested the diagnosis. Cerebrospinal fluid analysis showed bacterial meningitis which later revealed streptococcus pneumonia. The patient was treated with antibiotics and responded remarkably well. Repeat CT performed after 2 weeks of treatment showed complete resolution of the intracranial gas. Here, the authors report an unusual case of a pneumocephalus caused by meningitis in the absence of head trauma or a neurosurgical procedure.

3-Dimension 영상을 이용한 카메라 초점측정 및 동일축 이동 모델의 영상 정합 (Camera Focal Length Measuring Method and 3-Dimension Image Correspondence of the Axial Motion Model on Stereo Computer Vision)

  • 정기룡
    • 한국항해학회지
    • /
    • 제16권3호
    • /
    • pp.77-85
    • /
    • 1992
  • Camera arrangement for depth and image correspondence is very important to the computer vision. Two conventional comera arrangements for stereo computer vision are lateral model and axial motion model. In this paper, using the axial motion stereo camera model, the algorithm for camera focal length measurement and the surface smoothness with the radiance-irradiance is proposed fro 3-dimensional image correspondence on stereo computer vision. By adapting the above algorithm, camera focal length can be measured precisely and the resolution of 3-dimensional image correspondence has been improved comparing to that of the axial motion model without the radiance-irradiance relation.

  • PDF

Nanomechanical Properties Analysis on Polymer Blend Surfaces by Atomic Force Microscopy

  • Fujinami, So;Nakajima, Ken;Nishi, Toshio
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.340-340
    • /
    • 2006
  • Applying force-distance curve measurement by atomic force microscopy to a theoretical mechanical model gives us elastic properties of polymer surfaces. Our group focuses on force-mapping method, in which force-distance curve is performed at each lattice point on a sample surface and subsequently a variety of properties derived from analytical results are combined to construct a 2-dimensional image. With this method we succeeded in deriving Young' s modulus distribution map method of rubbery/rubbery polymer blend surfaces with ${\sim}100\;nm$ lateral resolution. We also applied force-mapping method to another theory to divide distribution of hardness from that of adhesion. We will demonstrate recent progress.

  • PDF

The Laser Range Finder for the Mobile Robot Navigation using a Lock-in Amplifier

  • Yoon, Hee-Sun;Shin, Myung-Kwan;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1423-1426
    • /
    • 2005
  • Map building is the most important thing for the mobile robots navigation. It requires specific vision system such as CCD camera, range finding system, and many other things. Laser range finder has highly collimated beams can be obtained easily, thus achieving lateral resolution. Laser Diode is used for a continuous laser source. The Automatic Current Control Circuit and the Bias-T is used for mix AC signal with DC bias. This signal is used for driving Laser Diode. The main idea of the calculating distance is detecting phase shift between reference signal and detected signal by photo detector. For the signal processing, the Lock-in amplifier system is addressed in this paper. We used a diffused reflected beam to detect phase shift in this system. But this beam is minuteness signal so it can be easily buried in nose. Lock-in amplifier is used to measure the amplitude and phase of signals which are buried in noise.

  • PDF

Application of Seismic Inversion to the Gas Field Development

  • Jo, Nam-Dae;Yang, Su-Yeong;Kim, Jae-Woo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 특별 심포지엄
    • /
    • pp.47-56
    • /
    • 2009
  • Proper reservoir characterization is an integral part of formation evaluation, reserve estimation and planning of field development. Seismic inversion is a widely employed reservoir characterization tool that provides various rock properties of reservoir intervals. This study presents results of the inversion studies including Geostatistical Inversion carried out on the gas fields, offshore Myanmar. Higher resolution and multiple models can be produced by Geostatistical Inversion using input data such as pre-stack seismic data, well logs, petrophysical relationships and geological inferences for example reservoir shape and lateral extent. Detailed reservoir characterization was required for the development plan of gas fields, and the Geostatistical Inversion studies served as a basis for integrated geological modeling and development well planning.

  • PDF