• Title/Summary/Keyword: Lateral plate fixation

Search Result 42, Processing Time 0.028 seconds

Comparative Study for the Fixation Method in the Danis-Weber Type B Lateral Malleolar Fractures: An Antiglide Plate Fixation versus A Lateral Plate Fixation (Danis-Weber B형 족관절 외과 골절의 고정방법 비교연구 : Antiglide 금속판 고정술 대 외측 금속판 고정술)

  • Shin, Hun-Kyu;Choi, Jae-Yeol;Kang, Dong-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.201-206
    • /
    • 2006
  • Purpose: To evaluate the advantages of the antiglide plate fixation procedure for Danis-Weber type B lateral malleolar fractures of ankle compared to other methods of lateral plate fixation. Materials and Methods: We reviewed 70 cases that antiglide plate fixation and lateral plate fixation procedures were performed from Mar. 2001 through Mar. 2006. Of the total 70 cases, they were divided into two groups ; 22 cases were treated with the antiglide plate procedure (Group I) and 48 cases were treated with the lateral plate procedure (Group II). The results of the two groups were analyzed both radiographically and clinically using Ankle-Hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS). Results: All fractures were healed at average of 8 weeks both radiographically and clinically. According to the Ankle-Hindfoot scale, all cases of Group I and 48 cases of Group II were above 80 points. 2 cases (9%) in Group I complained of peroneal tendinitis, while 19 cases (39%) in Group II showed skin irritation resulting from the screw or the plate. A total of 6 cases (27%) in Group I and 27 cases (55%) in Group II complained cosmetic problems. Conclusion: we concluded that the antiglide plate fixation for Danis-Weber type B lateral malleolar fractures is one of the good methods. But, further analysis will be need to find a solution for the peroneal tendinitis.

  • PDF

Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation (견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술)

  • Ko, Sang-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Clinical and Computed Tomography Evaluation of Plate and Screw on the Cervical Lateral Mass : A Modified Magerl's Technique

  • Lee, Dong-Chan;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Jong-Oon;Hyun, Dong-Keun;Park, Heon-Seon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.251-255
    • /
    • 2006
  • Objective : To determine the clinical and radiological safety of 15 consecutive patients managed with plate and screw fixation systems applied to the cervical lateral mass. Methods : 15 patients who underwent posterior cervical and T1 arthrodesis were reviewed from Jan 2002 to Dec 2004. Posterior cervical screw and plate fixation was applied on the lateral mass of the cervical spine. The authors have tried lateral mass screw fixation using a modified Magerl's technique [$20^{\circ}$ lateral and $20{\sim}30^{\circ}$ rostral screw trajectory] under preliminary radiological study. The average patient age was $39.73^{\circ}{\pm}11.00\;years$, and the average follow-up period was $9.73^{\circ}{\pm}6.77\;months$. Computed tomography scans taken after surgery were reviewed to confirm the attempted screw trajectory correct and safety. Results : Three of 93 lateral mass screws were malpositioned but clinical damage was not noted. Two of 8 pedicle screws on the T1 vertebrae were not placed on the correct pedicle area. Screw and plate loosening was observed in one case but was not subjected to an additional procedure because of maintained screw position observed during follow-up periods. Conclusion : The results of this study indicate that lateral mass screw fixation using the Modified Magerl's technique on the cervical lateral mass may provide safe and effective application on the patients. In addition, the chance of incorrectly placed screws was higher in T1 pedicle screw fixation than in lateral mass screw fixation of the cervical area.

Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate (Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료)

  • Ha, Sung-Sik;Hong, Ki-Do;Chung, Nam-Sik;Sim, Jae-Cheon;Ahn, Sang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Clinical and Radiological Outcomes of Hook Plate Fixation in the Lateral End Fracture of the Clavicle and Acromioclavicular Dislocation

  • Min, Young Kyoung;Kim, Jung Han;Gwak, Heui Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • Background: The purpose of this study was to identify the clinical and radiological outcomes of hook plate fixation for lateral end fracture of the clavicle and acromioclavicular dislocation. Methods: There were a total of 20 cases with lateral end fracture of the clavicle and 16 cases with acromioclavicular dislocation. All patients were evaluated for range of motion, functional score by using Constant score, and American Shoulder and Elbow Surgeons shoulder index at just before implant removal and at final follow-up. Coracoclavicular distance was measured in acromioclavicular dislocation and bony union was evaluated in the lateral end fracture of the clavicle. Results: The clinical outcomes and range of motion were increased at the final follow-up compared with just before implant removal in both the lateral end fracture of the clavicle and acromioclavicular dislocation. In acromioclavicular dislocation, all cases-except one-showed maintenance of reduction after implant removal. Moreover, in the lateral end fracture of the clavicle, all cases-except one-showed bony union. Conclusions: Hook plate fixation in the lateral end fracture of the clavicle and acromioclavicular dislocation resulted in good clinical and radiological results.

Comparison of Antiglide Plate Fixation and Lateral Plate Fixation for Danis-Weber Type B Isolated Lateral Malleolar Fractures (족관절 외과의 Danis-Weber B형 단독 골절에 있어서 활주 방지 금속판고정술과 외측 금속판고정술의 비교)

  • Ha, Joong-Won;Kim, Hyoung-Bok;Ko, Min-Suk;Yoon, Han-Kook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.153-158
    • /
    • 2011
  • Purpose: This study was performed retrospectively and to compare the clinical outcomes of the surgical management using Antiglide plating and lateral plating for Danis-Weber type B isolated lateral malleolar fractures. Materials and Methods: Between March 2004 and March 2009, 92 patients were followed up for more than 6 months after surgical treatment. 49 patients were treated with Antiglide plating, whereas the remaining 43 patients underwent lateral plating. The results of the two groups were analyzed both radiographically and clinically using Ankle scoring system. Results: Both groups were comparable for age, sex distribution, time to surgery, and operation time. Bone union was noted at average of 8 weeks in all fractures. The mean ankle score was similar in both groups (94% versus 93%). Conclusion: Antiglide plating for Danis-Weber type B isolated lateral malleolar fracture is one of the good methods which has some advantages such as early ankle motion, ambulation and smaller operative incision.

The Anti-glide Plate in the Treatment of Lateral malleloar fracture (Antiglide 금속판을 이용한 족관절의 외과 골절의 치료)

  • Kim, Do-Young;Shin, Joo-Ho;Cho, Won-Ho;Hwang, Hyun-Chull
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2001
  • Most of Danis-Weber type B fracture has an oblique fracture plane proximal posteriorly to distal anteriorly. In these cases, the lateral plate has become widely accepted. However some limitation to the use of the lateral plate exist. The plate must be bent accurately and the screws in the distal fragment must be unicortical to avoid penetration into the joint, predisposing it to poor fixation in the osteoporotic bone. In 1982, Brunner and Weber introduced the antiglide plate for fixation of the shaft oblique fracture of the distal fibula, but it has not widely used. The author reviewed 21 cases treated by antiglide plate fixation from March, 1995 to March, 1999 which could be follow-up more than 1 year. We analysed the result radiographically and clinically using Ankle-Hindfoot scale(100 % total) of the American Orthopedic Foot and Ankle Society. The results obrained were as follows: 1. All fracture were united at average 8 weeks clinically and radiographically. 2. According to the Ankle- Hindfoot scale, 8 cases were above 90 points, 11 cases were beet ween 80 and 89 points and two cases were below 80 points. 3. One case had an injury to intermediate dorsal cutaneous nerve.

  • PDF

Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures (종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교)

  • Lee, Yun-Tae;Oh, Hyun-Cheol;Yoon, Han-Kook;Jang, Jae-Won;Jang, Ki-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

Acromion Fracture after Hook Plate Fixation for Distal Clavicle Injury: A Report of 2 Cases

  • Kang, Suk;Lee, Ho Min;Back, In Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.168-171
    • /
    • 2016
  • Fractures at the lateral end of the clavicle inevitably require surgical treatment as there is high potential for delayed union or nonunion. Acromioclavicular dislocation also requires stable and solid fixation for healing, and surgical treatment is recommended for the maintenance of joint function. The hook plate maintains the biomechanics of the acromioclavicular joint, enabling early range of motion. Therefore, for the past 10 years, the hook plate has been widely used in distal clavicle fractures and acromioclavicular joint injuries. However, the hook plate is associated with several complications, such as proximal clavicle fractures, widening of the hook hole, rotator cuff tear, subacromial impingement, and often acromial fractures. We report on two unusual cases of acromion fracture after hook plate fixation in patients with distal clavicle fracture and acromioclavicular dislocation alongside a literature review.

Treatment for Distal Humeral Fractures by Modified Anatomical Y-Plate (변형된 Y형 해부학적 금속판을 이용한 상완골 원위부 골절의 치료)

  • Moon Eun Sun;Park Jae Hyung;Lee Young Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1998
  • Comminuted fracture of the distal end of the humerus in adults is very rare and difficult to treat. In operative treatment, an implant which can achieve accurate anatoraical reduction and rigid fixation is needed. But the pre­existing Y -shaped plate had wide and thick limbs and some problems in fixation for most distal humeral fractures. So we devised a modified plate which is more narrow and th1n and has a different hole distance and wing length (long lateral wing). The aim of the study was to evaluate the clinical result of this modified anatomical Y -plate. From 1991 to 1997, we treated 23 cases of distal humeral fractures using modified anatomical plate and the results were as follows. 1. Fracture type in 18 patients(78%) was C-type(C1,C2,C3) which were intraarticular and mostly displaced or comminuted. 2. Bony union was obtained in 22 patients(96%) through rigid fixation and observed radiologically at 3.5 months(2-6months) on the average. 3. In 23 patients, 19 patients(82%) showed satisfactory results after 34 months(6-73months) follow-up. So if the modified anatomical Y-plate is used in the treatment of distal humeral fracture, a satisfactory result can be obtained through a more accurate, easy, and rigid fixation than preexisting plate.

  • PDF