• Title/Summary/Keyword: Lateral groove angle

Search Result 12, Processing Time 0.116 seconds

The Study on PRAT Performance due to Tire Pattern Shapes using Steady State Rolling Analysis Method (정상 상태 롤링 해석 기법 적용을 통한 타이어 패턴 형상에 따른 PRAT 특성 연구)

  • Sung, Ki-Deug;Park, Hyun-Man;Koo, Byong-Kook;Cho, Choon-Tack
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.15-21
    • /
    • 2008
  • It is generally known that the PRAT(Plysteer Residual Aligning Torque) is one of indicating a performance factors of a tire for assessing the vehicle pull, also tire pattern shape, which means lateral groove angle, is very important tire design factor in relation to the PRAT. Lateral grooves of tire pattern are widely divided into center and shoulder parts. So, this paper has studied the correlation between the PRAT and their lateral groove angles using FEM. Especially, the steady state rolling analysis among tire rolling analysis methods has been used for the PRAT performance study. Firstly, analysis result data have been compared with the experimental data to validate FE analysis for PRAT. Next, the PRAT due to the lateral groove angle about PCR(Passenger Car Radial) tire and SUV tire has been analyzed. The tendency of the PRAT due to the lateral groove angles can be used as a guide line for the tire design in relation to vehicle pull.

A Study on the Radiant Emission Characteristics of Isothermal and Diffuse Equi-Lateral Trapezoid Groove Cavity (等溫 - 擴散 等邊사다리꼴 홈 Cavity 의 輻射放射率 特性 에 관한 硏究)

  • 박희용;이승호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.294-300
    • /
    • 1983
  • The purpose of this study is to investigate the radiant emission characteristics of diffuse equi-lateral trapezoid groove cavity for the case of uniform surface temperature. The theoretically developed results for the apparent emissivity are presented and the values of apparent emissivity for the trapezoid groove cavity were compared with those of the V-groove cavity. In the experimental part of this study, the test models were manufactured from 100x 100x 15mm copper plates on which the equi-lateral trapezoid cavities were grooved. The inclined angles of the groove were 30,45 and 60 degrees and the ratio of groove depth to base surface width varied from 1 to 5 for each inclined angle. As a result of this work, it was found that the trapezoid groove cavity was more general form of V-groove and the apparent emissivity of trapezoid groove cavity was greater than that of V-groove cavity. The resulting equation for the apparent emissivity in the trapezoid groove cavity was valid for the angles greater than 40 degrees.

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

A STUDY ON THE BOND STRENGTH OF RESIN-RETAINED PROTHESIS WITH VARIOUS CAST RETAINER DESIGNS (주조체의 설계 변화에 따른 수지접착형 보철물의 접착강도에 관한 연구)

  • Joo Dae-Won;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.508-525
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of some resistance form designs on the bond strength of resin-retained prosthesis. Six sub-groups are designed in natural teeth group and resin teeth group . The framework designs in natural teeth group: 1) no groove preparation 2) groove at the center of distal surface 3) groove at the distobuccal line angle 4) 45 degree lateral load with no groove 5) 45 degree lateral load with center groove 6) splint two teeth with no groove. The framework designs in resin teeth group: 1) no groove preparation 2) groove at the center of distal surface 3) groove at the distobuccal line angle 4) metal covered the 1/2 of distal surface 5) metal covered the 1/2 of mesial surface 6) metal extended over the 114 of buccal surface. Specimens were treated electrolytic etching by Oxy-Etch and cemented with Panavia EX. Failure load was measured by Instron. Another 30 specimens were carried out fatigue tests by MTS 810 fatigue testing machine for 5000 cycles at different load level. The following results were obtained from this study. 1. The failure load was significantly increased by resistance forms. 2. The failure load was not increased by increase of total surface area bonded with teeth. The distal surface area played an important role in failure load. 3. In 45 degree lateral load group, the failure load was decreased significantly than that of in vertical load group. 4. Bond failure modes between static test and fatigue test exhibited no differences.

  • PDF

A Study on the Lubrication Characteristics of Spool Valve with Spiral Groove (스파이럴 그루브가 가공된 스풀밸브의 윤활 특성 연구)

  • Hong, Sung-Ho;Son, Sang-Ik;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.303-314
    • /
    • 2012
  • In this research, spool valves with spiral grooves are suggested and their lubrication characteristics are investigated by numerical analysis. The three-dimensional flow field is obtained by solving the Navier-Stokes equations in dimensionless form, so that the performance variables such as lateral force, friction force and volume flow rate are determined. Also, the lubrication characteristics of spool valves with spiral grooves are compared with those with typical grooves under variable working conditions. It is shown that spool valves with spiral grooves can get better performance in aspect of mitigation of uneven pressure distribution surrounding spool. Moreover, it is found that the minimum distance between spool edges and grooves, the type of spiral groove, and the groove angle have noticeable effect on the lubrication characteristics.

Bilateral Patellar Groove Replacement in a Dog with Iatrogenic Trochlear Groove Damage

  • Kim, Yongrak;Park, Yunsik;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.33 no.5
    • /
    • pp.295-299
    • /
    • 2016
  • A 2-year-old, 1.94 kg spayed female Toy Poodle was referred for revision surgery for patellar reluxation following surgery for bilateral medial patellar luxation (MPL). Intermittent non-weight-bearing lameness of the right hindlimb and weight-bearing lameness of the left hindlimb were evident on general inspection. A physical examination revealed that there was a bilateral grade 4 MPL. On radiographs, the medial and lateral trochlear ridge was bilaterally worn out. Patellar groove replacement (PGR) was performed in two stages to replace the bilateral femoral trochlea that had a severely worn out groove. Corrective femoral osteotomy with increasing anteversion angle, tibial tuberosity transposition, medial releasing, lateral imbrications and PGR were performed on the right hindlimb. Six months after surgery on the right hindlimb, a PGR prosthesis was positioned medially on the frontal plane and tibial tuberosity transposition and lateral imbrications were performed on the left hindlimb. Two weeks after surgery, reluxation of the patella occurred on the left hindlimb. The tibial tuberosity transposition was performed to realign the patella more laterally than the previous surgery, and a patellar sling was applied. Two years after the last surgery, the patient showed no pain on the stifle joint and satisfactory weight-bearing ambulation. Reluxation did not recur. PGR maybe a successful treatment for dogs with iatrogenically damaged and/or worn out patellar grooves.

Lateral nasal advancement flap for reconstruction of the nasal sidewall and dorsum

  • Ogawa, Yutaka;Ogawa, Yasuko
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.102-105
    • /
    • 2020
  • Malignant skin tumors and precancerous lesions have a predilection to be located in the nasal dorsum or sidewall. Although invasive reconstructions have been presented, no simple and suitable method has yet been reported for this area. The flap presented herein, named the lateral nasal advancement flap, is designed on the adjacent lateral region of the sidewall or nasal dorsum and advanced in the medial direction. Two Burow's triangles are removed in the upper and lower portions of the flap: the upper triangle along the nasofacial sulcus and the lower triangle along the nasofacial sulcus and/or the alar groove. Excellent results were obtained in the two clinical cases described in this report. Neither a trap door deformity nor dog-ears developed in either case. The postsurgical scars followed the aesthetic lines and became inconspicuous. A distinct angle was formed in the nasofacial sulcus without anchor sutures. This surgical procedure is technically simple and is performed under local anesthesia. Although the flap is a cheek-based advancement flap, postsurgical scars do not remain in the cheek; instead, they are located in the nasofacial sulcus and alar groove. The lateral nasal advancement flap is recommended for reconstruction of the nasal sidewall and dorsum.

Humeral, Glenoid Retroversion and Bicipital Groove Distance of the Normal Korean Adults (정상 한국 성인의 상완골과 관절와의 후경각 및 개방적 수술의 비교)

  • Kim Jin Sub;Yoo, Jung Han;Park Joo Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.151-156
    • /
    • 1999
  • Purpose : Average humeral head retroversion was showed significant wide range from literatures based on variable measuring technique, We performed computed tomography(CT) study in an effort to define the specific anatomy relationships and evaluate their use. Materials and Methods : Two hundreds shoulders and distal humeri CT scan with no known pathology were examined. The study population was divided to 10 groups by gender and age (from third to seventh decade). The number of each group was twenty. Retroversion of proximal humerus and glenoid were measured using the lines that were connected the central axis of humeral head, central points of the humeral epicondyles paralleling to the trochlea, paralled to the glenoid surface, midpoint between the transverse glenoid diameter and medial edge of the scapular. We also measured the bicipital groove distance from the humeral central axis and scapulothoracic angle. Results: Retroversion of proximal humerus was highly variable, ranging in this study from 13 to 58 degrees(mean 28.73) These values correlated with sex, not age, height or hand dominance. Glenoid retroversion at the inferior sections showed average 1.3 degree, did not signigicant differences. The central axis was an average of l0mm(5-15mm) posterior to the posterior margin of the bicipital groove. Scapulothoracic angle was average 43 degrees(25-53 degrees) Conclusion: Anatomical reconstruction of retroversion angle should be individualized and bicipital groove could be useful as landmark for the lateral fin of the prosthesis to be positioned an average of 10mm posteriorly.

  • PDF

Structure Optimization of a Slot-Die Head with a Hydrophobic Micro-Patterns for Stripe Coatings (소수성 마이크로 패턴을 갖는 Stripe 코팅용 슬롯 다이 헤드 구조 최적화)

  • Yoo, Su-Ho;Lee, Jin-Young;Park, Jong-Woon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.6-10
    • /
    • 2019
  • In the presence of $\mu-tip$ for narrow stripe coating, there appears lateral capillary flow along the hydrophilic head lip because the $\mu-tip$ has some resistance to flow. It was known to be suppressed by increasing the contact angle of the head lip. In this paper, we have demonstrated by computational fluid dynamics(CFD) simulations that it can also be suppressed by the formation of micro-patterns on the shim and meniscus guide embedded into the slot-die head. To optimize the micro-patterned structure, we have performed simulations by varying the groove width, depth, and clearance. In the absence of micro-patterns, it is shown by experiment and simulation that the solution spreads to a distance of $1,300{\mu}m$ from the ${\mu}-tip$. In the presence of micro-patterns with the groove width and clearance of $50{\mu}m$, the distance the solution spreads is reduced to $260{\mu}m$. However, no further suppression in the capillary flow is observed with micro-patterns with the groove width of $40{\mu}m$ or less. It is also observed that the capillary flow is not affected by the groove depth if it is larger than $10{\mu}m$. We have shown that the distance the solution spreads can be reduced further to $204{\mu}m$ by coating a hydrophobic material (contact angle of $104^{\circ}$) on the surface of micro-patterns having the groove width and clearance of $50{\mu}m$.

Patellofemoral Instability in Children: Imaging Findings and Therapeutic Approaches

  • Hee Kyung Kim;Shital Parikh
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.674-687
    • /
    • 2022
  • Patellofemoral instability (PFI) is common in pediatric knee injuries. PFI results from loss of balance in the dynamic relationship of the patella in the femoral trochlear groove. Patellar lateral dislocation, which is at the extreme of the PFI, results from medial stabilizer injury and leads to the patella hitting the lateral femoral condyle. Multiple contributing factors to PFI have been described, including anatomical variants and altered biomechanics. Femoral condyle dysplasia is a major risk factor for PFI. Medial stabilizer injury contributes to PFI by creating an imbalance in dynamic vectors of the patella. Increased Q angle, femoral anteversion, and lateral insertion of the patellar tendon are additional contributing factors that affect dynamic vectors on the patella. An imbalance in the dynamics results in patellofemoral malalignment, which can be recognized by the presence of patella alta, patellar lateral tilt, and lateral subluxation. Dynamic cross-sectional images are useful for in vivo tracking of the patella in patients with PFI. Therapeutic approaches aim to restore normal patellofemoral dynamics and prevent persistent PFI. In this article, the imaging findings of PFI, including risk factors and characteristic findings of acute lateral patellar dislocation, are reviewed. Non-surgical and surgical approaches to PFI in pediatric patients are discussed.