• Title/Summary/Keyword: Lateral drift capacity

Search Result 87, Processing Time 0.024 seconds

Structural Performance Evaluation of Repaired Structural Walls (보수된 전단벽의 강도 및 변형능력 회복 여부에 관한 연구)

  • 유승욱;한상환;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.525-528
    • /
    • 1999
  • Structural walls have been favored for the design of reinforced concrete buildings in seismic zone areas because they provide an efficient bracing system and offer great potential for lateral load resistance and drift control. Loads on structures due to earthquakes are not unlikely to reach, if not exceed, the design load levels. Hence, structural damage to walls is inevitable, and it is necessary to repair this damaged walls. Yet, information on repair method and data related to the strength and deformation characteristics of repaired walls is limited. In this study, specimens which have their aspect ratios of about 1 to 3 will be repaired. For the repairing the damaged walls, new concrete and new reinforcing bar are replaced with cracked concrete and the buckled reinforcing bar, respectively. The objective of this study is to evaluate the performance of the repaired structural walls in the capacity of strength, stiffness, and maximum deformation comparing with the undamaged walls.

  • PDF

Comparison of Motion Control Capacity of Viscous and Viscoelastic Dampers for Lateral Loads (횡하중에 대한 점성 및 점탄성감쇠기의 진동제어성능의 비교)

  • Kim, Jin-Koo;Kim, Yu-Kyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.155-162
    • /
    • 2001
  • In this study a structure with viscoelastic and viscous dampers with identical damping coefficient subjected to stationary seismic and wind load were analyzed in time and frequency-domain to compare motion control capability of viscous and viscoelastic dampers. The dampers were placed based on story drift and acceleration obtained from RMS responses. According to the analysis results, the motion control capability of viscous dampers turned out to be superior to that of the viscoelastic dampers for the case of seismic load. On the contrary, in case of wind load, the viscoelastic dampers were more effective in the mitigation of dynamic responses. However, it was also found that the differences were in a narrow margin.

  • PDF

A Study on the Behavior Properties of Residential-Commercial Building by Pushover Analysis (정적탄소성해석에 의한 복합구조물의 거동특성에 관한 연구)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.209-216
    • /
    • 2000
  • The purpose of this study is to investigate elasto-plastic behaviour and estimate ultimate resistance capacity of the residential-commercial building subjected to lateral force along the height of structure. Four types of residential-commercial building are chosen as analytical models and investigated by pushover analysis. Pushover analysis estimates initial elastic stiffness, post-yielding stiffness, and plastic hinges on each story of structures through three-dimensional nonlinear analysis program CANNY-99. Skeleton curve of bending stiffness model is bilinear, shear stiffness model is trilinear, and axial stiffness model is elastic. Skeleton curve of axial stiffness model has the axial compression and tension stiffness of reinforced concrete members. This study presents the change of inter story drift, story stiffness and hinge of story and member.

  • PDF

The cyclic behavior of steel-polyoxymethylene composite braces

  • Demir, Serhat
    • Structural Engineering and Mechanics
    • /
    • v.70 no.5
    • /
    • pp.591-600
    • /
    • 2019
  • Steel tubular buckling controlled braces are well known as being simple, practical and cost-effective lateral force resisting systems. Although these system features have gained the attention of the researchers over the last decade, steel tubular buckling controlled braces currently have limited application. Indeed, only a few steel tubes tightly encased within each other exist in the steel industry. In this paper, a new and practical design method is proposed in order to better promote the widespeared application for current steel tubular buckling controlled brace applications. In order to reach this goal, a holed-adapter made with polyoxymethylene adaptable to all round and square steel sections, was developed to use as infiller. The research program presents designing, producing and displacement controlled cyclic loading tests of a conventional tubular brace and a buckling controlled composite brace. In addition, numerical analysis was carried out to compare the experimental results. As a result of the experimental studies, buckling was controlled up to 0.88 % drift ratio and the energy dissipation capacity of the conventional tubular brace increased 1.46 times due to the proposed design. The main conclusion of this research is that polyoxymethylene is a highly suitable material for the production of steel tubular buckling controlled braces.

Evaluation and Improvement of Deformation Capacities of Shear Walls Using Displacement-Based Seismic Design

  • Oh, Young-Hun;Han, Sang-Whan;Choi, Yeoh-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.55-61
    • /
    • 2006
  • RC shear walls are frequently used as lateral force-resisting system in building construction because they have sufficient stiffness and strength against damage and collapse. If RC shear walls are properly designed and proportioned, these walls can also behave as ductile flexural members like cantilevered beams. To achieve this goal, the designer should provide adequate strength and deformation capacity of shear walls corresponding to the anticipated deformation level. In this study, the level of demands for deformation of shear walls was investigated using a displacement-based design approach. Also, deformation capacities of shear walls are evaluated through laboratory tests of shear walls with specific transverse confinement widely used in Korea. Four full-scale wall specimens with different wall boundary details and cross-sections were constructed for the experiment. The displacement-based design approach could be used to determine the deformation demands and capacities depending on the aspect ratio, ratio of wall area to floor plan area, flexural reinforcement ratio, and axial load ratio. Also, the specific boundary detailing for shear wall can be applied to enhance the deformation capacity of the shear wall.

Effects of loading history on seismic performance of SRC T-shaped column, Part I: Loading along web

  • Wang, J.;Liu, Z.Q.;Xue, J.Y.;Hu, C.M.
    • Structural Engineering and Mechanics
    • /
    • v.68 no.2
    • /
    • pp.193-201
    • /
    • 2018
  • This paper describes an experimental study on the seismic performance of steel reinforced concrete (SRC) T-shaped columns. The lateral loads were applied along the web of the column with different loading histories, such as monotonic loading, mixed loading of variable amplitude cyclic loading and monotonic loading, constant amplitude cyclic loading and variable amplitude cyclic loading. The failure modes, load-displacement curves, characteristic loads and displacements, ductility, strength and stiffness degradations and energy dissipation capacity of the column were analyzed. The effects of loading history on the seismic performance were focused on. The test results show that the specimens behaved differently in the aspects of the failure mode subject to different loading history, although all the failure modes can be summarized as flexural failure. The hysteretic loops of specimens are plump, and minimum values of the failure drift angles and ductility coefficients are 1/24 and 4.64, respectively, which reflect good seismic performance of SRC T-shaped column. With the increasing numbers of loading cycles, the column reveals lower bearing capacity and ductility. The strength and stiffness of the column with variable amplitude cyclic loading degrades more rapidly than that with constant amplitude cyclic loading, and the total cumulative dissipated energy of the former is less.

Strength of Interior Post-Tensioned Flat Plate Slab-Column Connection based on Failure Mechanism (파괴 메커니즘을 고려한 내부 포스트텐션 플랫 플레이트 슬래브-기둥 접합부의 강도식 평가)

  • Kim, Min-Nam;Ha, Sang-Su;Lee, Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.126-129
    • /
    • 2006
  • A bending moment $M_u$ transferred at slab-column connection is resisted at the slab critical section by flexure and shear. The ACI 318-05 Building Code(1) gives an empirical equation for the fraction ${\gamma}_{\upsilon}$ of the moment $M_u$ to be transferred by shear at the slab critical section at d/2 from the column face and also the effective wide(c+3h). The equation is based on tests of interior slab-column connections without shear reinforcement. In order to investigate the data eight test specimens were examined. The test shows that increased slab load substantially reduces both the unbalanced moment capacity and the lateral drift capacity of the connection. Especially, the specimens with the bottom reinforcement existence and nonexistence, appears remarkable differences. Studies also show that the code equation for ${\gamma}_{\upsilon}$ does not apply to all cases. The purpose of this study is to compare the test results with present ACI 318-05 Building Code provisions for design of slab-column connections and with the analysis of the experimental data for a new limitation of strength equation without shear reinforcement and bottom reinforcement.

  • PDF

The Nonlinear Behavior Characteristics of the 3D Mixed Building Structures with Variations in the Lower Stories (입체 복합구조물의 하부골조 층수 변화에 따른 비선형 거동특성)

  • 강병두;전대한;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • The upper wall-lower frame structures(mixed building structures) are usually composed of shear wall structure in the upper part of structure which is used as residential space and frame structure in the lower part of structure which is used as commercial space centering around the transfer system in the lower part of structure. These structures are characteristics of stiffness irregularity, mass irregularity, and vertical geometric irregularity. The purpose of this study is to investigate the nonlinear response characteristics and the seismic capacity of mixed building structures when the number of stories in the lower frame is varied. The conclusions of this study are following. 1) As the result of push-over analysis of structure such as roof drift(i.e. roof displacement/structural height) and base shear coefficient, when the stories of lower frame system are increased, base shear coefficient is decreased, but roof drift is increased. 2) According to an increase in stories of the lower fame, story drift and ductility ratio of upper wall system are decreased and behavior of upper wall system is closed to elastic. 3) When the stories of lower frame system are increased, the excessive story drift is concentrated on the lower frame system.

Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties - (낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 -)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • Shearing strength test in tension type was investigated to determine the shear resistance of bolt and drift-pin connection of domestic larix glulam. The specimen was connected with bolt and drift-pin in the inserted plate type, and only bolt in the side plate type. The diameter of bolt and drift-pin used in the experiment are 12, 16 and 20 mm. The hole of bolt was drilled at the end-distance 5 d and 7 d. Tension load was loaded in the direction parallel to grain. The shear resistance was evaluated according to end-distance through this, the yield load was compared with the experimental yield load, using Larsen's formula. The prototype design strength is based on the yield load of end-distance 7 d and the reduction factor of end-distance 5 d was calculated. The results were as follows. 1. The average of maximum load of drift-pin connection was higher by 3~30% at the inserted type than at bolt connection with increasing diameter. In bolt connection, the average of maximum load of the side type was 1.54~2.07 times higher than that of the inserted type. In the same diameter, the average of maximum load of end-distance 7 d was higher by 8~44% than that of 5 d. 2. The bearing stress was 1.16~1.41 times higher at the inserted connection than at drift-pin connection, and 1.37~1.86 times higher at 7 d than at 5 d. Also, when the slenderness ratio was below 7.5 at drift-pin connection and below 6.0 at inserted connection, the lateral capacity was good. 3. The ratio of the experimental yield load and the predicted yield load calculated by Larsen's formula proposed by Larsen was 0.80~1.10 at inserted connection, and 0.75~1.46 at side connection. 4. When the inserted bolt connection was based on the yield load of end-distance 7 d, the reduction factor was 0.89 at 12 mm connection, 0.93 at 16 mm and 0.85 at 20 mm. The reduction factor was 0.89 at 12 mm the inserted drift-pin connection, 0.93 at 16 mm, 0.93 at 20 mm. The reduction factor was 0.79 at the side connection of the 12 mm bolt connection and 0.80 at 16 mm.

Performance of Repaired Structural Walls with Different Shear Span Ratios (전단스팬비가 다른 보수된 벽체의 성능평가)

  • Han, Sang-Whan;Oh, Chang-Hak;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • The purpose of this study is to evaluate the capacities of repaired structural walls with different shear span ratios(1, 2, 3). Experimental tests were carried out. In this study three isolated large-scale wall specimens were made. The original wall specimens were tested until the drift reaches more than 3%. The region of the damaged specimen with the crack larger than 0.2 mm is replaced by new concrete. Also, severly distorted reinforcements were also replaced by new reinforcements. The crack smaller than 0.2 mm was cured by epoxy resin. Because of the space limitation of the laboratory the dimensions of all walls are the same. The shear-span ratio was controlled by the combination of axial and lateral force using the special test setting. All specimens were tested using the incremental quasi static cyclic load until failure occurs. Test results show that strength of repaired walls was almost equivalent to that of original walls. However, deformation capacities of repaired wall specimens are inferior to the original wall specimens.