International Journal of Vascular Biomedical Engineering
/
제3권2호
/
pp.10-16
/
2005
Because patients with coronary artery disease (CAD) have depressed vagal modulation and the mortality risk from acute myocardial infarction is lower in patients with higher vagal modulation, methods that can increase vagal modulation are desirable in patients with CAD. We intended to inspect the effect of recumbent posture on vagal modulation. By using angiography, 33 patients with abnormal (CAD group) and 33 patients with normal coronary arteries (control group) were studied. The nonlinear as well as the linear characteristics of heart rate variability (HRV) were analyzed on these patients in three recumbent postures: namely, the supine, right lateral decubitus, and left lateral decubitus postures. The lower the normalized high-frequency power (nHF) in the supine or left lateral decubitus posture, the higher the increase in the nHF when the posture was changed from supine or left lateral decubitus to right lateral decubitus in both groups of patients. Right lateral decubitus posture can lead to the highest vagal modulation and the lowest sympathetic modulation among the three recumbent postures in both normal and patients with CAD. Therefore, the right lateral decubitus posture can be used as an effective physiologic vagal enhancer in patients with CAD.
Chest lateral decubitus is a chest examination to determine the persence of pleural fluid in thorax. In this study, we prepare recumbent holding position time standard of chest lateral decubitus. The records of 15 patients with chest lateral decubitus between May and Jun. Recumbent holding time is 30, 60, 90, 120, 180, 210, 240 seconds. The result is fluid level change between 0.88mm to 9.63. Fluid heigh change between 9.9 percent to 42.5 percent. We can confirm fluid level change with chest decubitus image. The proper time for fluid level change is 180 seconds.
It is widely recognized that manipulation of body position takes advantage of the influences of gravity for improving oxygenation. The study aims to determine the effects of positioning(supine, prone, right lateral decubitus and left lateral decubitus positions) applied to the mechanically ventilatory acute respiratory failure patients on arterial oxygen partial pressure($PaO_2$), alveolar arterial oxygen tension difference($AaDO_2$), mean aterial pressure, peak inspiratory pressure and plateau pressure. Thirty two acute respiratory failure patients admitted to the medical intensive care unit at Kangnam St. Mary's Hospital, The Catholic University of Korea from March 1997 to January 1998, were divided into three groups by radiographic evidence of unilateral or bilateral lung disease. In group 1 with dominant right lung disease were twelve subjects, group 2 with dominant left lung disease had eight subjects and group 3 had twelve subjects with bilateral lung disease. The variables were measured in 30 minutes after each position of supine, prone, good lung down lateral decubitus and sick lung down lateral decubitus position. The position order was done at random by Latin squre design. The results are as follows; 1) With group 1 patients, the $PaO_2$ in the left lateral decubitus and prone position were $126.8{\pm}30.8$ mmHg and $106.7{\pm}36.8$ mmHg, respectively(p=0.0001). 2) With group 2 patients, the $PaO_2$ in the prone and the right lateral decubitus position were $121.7{\pm}44.7$ mmHg and $118.5{\pm}31.7$ mmHg, respectively (p=0.0018). 3) With group 3 patients, the $PaO_2$ was $143.6{\pm}36.6$ mmHg in the prone position (p=0.0001). 4) With group 1 patients, the $AaDO_2$ in the left lateral decubitus and the right lateral decubitus position were $178.1{\pm}29.7$ mmHg and $233.1{\pm}24.4$ mmHg, respectively(p=0.0001). 5) With group 2 patients, the $AaDO_2$ in the prone and the left lateral decubitus postion were $184.0{\pm}39.5$ mmHg and $231.0{\pm}23.9$ mmHg, respectively(p=0.0019). 6) With group 3 patients, the $AaDO_2$ in the prone and the supine postion were $377.1{\pm}35.6$ mmHg and $435.7{\pm}13.1$ mmHg, respectively (p=0.0001). 7) There were no differences among the mean arterial pressure, peak inspiratory pressure and plateau pressure for each of the supine, prone, left lateral decubitus and right lateral decubitus position. The results suggest that oxygenation may improve in mechanically ventilatory patients with unilateral lung disease when the position is good lung dependent and prone, and patients with bilateral lung disease when the position is prone without any effects on the mean arterial pressure and airway pressure. It is suggested that body positions improve ventilation/perfusion matching and oxygenation need to be specified in patient care plans.
Chest lateral decubitus 촬영은 일반적으로 PA 검사를 시행하여 왔으나, 응급환자나 몸이 불편한 환자의 검사에 있어 많은 불편이 있었다. 이에 본 연구에서는 AP 검사와 PA 검사를 비교하여 영상의 질, 환자의 안전성, 검사 효율성을 분석하고 두 검사간의 유용성을 알아보고자 하였다. 본원에서 2011.10.1 ~ 2012.7.30까지 늑막염 또는 기흉으로 의심되거나 진단된 환자들 중 chest lateral decubitus 촬영을 시행한 30명(남자 20명, 여자 10명)을 대상으로 하였다. 영상 화질 평가방법은 폐야의 미세구조, 진단영역의 넓음, air-fluid 경계면의 명확 유무, 환자 회전유무, 심장음영과 횡격막의 선명유무를 기준으로 하였으며, 영상의학과 전문의 2명, 호흡기내과 전공의 2명이 blind test로 평가하였다. 환자 안정성 및 방사선 검사의 효율성 평가는 환자 position의 안정성, 환자 상태 확인 등의 기준으로 일반촬영 5년 이상 경력의 방사선사 15명이 5점 척도로 평가를 하였고, 통계 분석은 Paired T-test로 분석하였다. Chest decubitus 촬영 시 AP와 PA자세에 따른 검사의 유용성을 비교 분석한 결과 영상의 화질에서 AP와 PA자세는 큰 차이가 없었던 반면, 환자의 안정성 및 방사선사의 검사 효율성에 있어 PA자세에 비해 AP자세의 평가 점수가 높게 나타났다. 이에 특별히 PA자세가 요구되지 않는다면 AP자세로 검사하여도 무방할 것으로 사료된다.
Purpose: Internal fixation using compression hip screws (CHS) and traction tables placing patients in the supine position is a gold standard option for treating intertrochanteric fractures; however, at our institution, we approach this treatment with patients in a lateral decubitus position. Here, the results of 100 consecutive elderly (i.e., ${\geq}45$ years of age) patients who underwent internal fixation with CHS in lateral decubitus position are analyzed. Materials and Methods: Between March 2009 and May 2011, 100 consecutive elderly patients who underwent internal fixation with CHS for femoral intertrochanteric fracture were retrospectively reviewed. Clinical outcomes (i.e., Koval score, Harris hip score [HHS]) and radiographic outcomes (i.e., bone union time, amount of sliding of lag screw, tip-apex distance [TAD]) were evaluated. Results: Clinical assessments revealed that the average postoperative Koval score decreased from 1.4 to 2.6 (range, 0-5; P<0.05); HHS was 85 (range, 72-90); and mean bone union time was 5.0 (range, 2.0-8.2) months. Radiographic assessments revealed that anteroposterior average TAD was 6.95 (range, 1.27-14.63) mm; lateral average TAD was 7.26 (range, 1.20-18.43) mm; total average TAD was 14.21 (range, 2.47-28.66) mm; average lag screw sliding was 4.63 (range, 0-44.81) mm; and average angulation was varus $0.72^{\circ}$(range, $-7.6^{\circ}-12.7^{\circ}$). There were no cases of screw tip migration or nonunion, however, there were four cases of excessive screw sliding and six cases of varus angulation at more than $5^{\circ}$. Conclusion: CHS fixation in lateral decubitus position provides favorable clinical and radiological outcomes. This technique is advisable for regular CHS fixation of intertrochanteric fractures.
Object: To evaluate the efficiencies of the arthroscopic rotator cuff surgery which is Performed without the traction system in the lateral decubitus position. Methods: Twenty-nine cases of the arthroscopic rotator cuff surgery performed without the traction system in the lateral decubitus position were studied from February, 2002 to January, 2005. We performed a repair using the arthroscopic debridement and the arthroscopic rotator cuff repair, or using the mini-open incision technique after the confirmation of rotator cuff tear, then, the arthroscopic subacromial decompression was performed after the confirmation of subacromial lesions Results: We could easily find the subscapularis tear which was often overlooked in the arthroscopic rotator cuff surgery performed with the traction surgery by the relaxation of the subscapularis, as the arm position was internally rotate about 45 to 70 degrees from abducted position. We found that the operation time was reduced 14 minutes shorter than the operation time of the controlled group which had the surgery with the traction system on the average. We also found that there were no neurovascular complications from all cases. Conclusions: The arthroscopic rotator cuff surgery without traction system in the lateral decubitus position provided the better visual field, easy manipulation of the joint and reducing operation time.
The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.
본 연구는 디지털 흉부 측와위 후전방향 검사 시 Ion chamber 설정과 관전압 변화에 따른 피폭선량과 변조전달함수를 측정하여 최적의 진단 영상을 획득하고 환자의 피폭선량을 최소화하는 방안에 대하여 제안하고자 하였다. 실험은 디지털 검출기를 이용하여 흉부 측와위 검사법 중 우측 측와위 상태를 가정하여 Ion chamber를 7가지 조합으로 설정하고, 관전압 변화(100, 110, 120, 130 kVp)에 따라 각 5회씩 촬영하여 표면선량을 측정한 후 평균값을 산출하였다. 실험에서 얻어진 표면선량 값을 몬테카를로 시뮬레이션 프로그램 인 PCXMC에 입력하여 장기선량 및 유효선량을 각각 산출하였고, 영상의 화질을 비교하기 위하여 MTF로 물리적 화질 평가를 하였다. 그 결과 관전압이 높을수록 표면선량이 감소하였으며, Ion chamber 변화에 따른 장기선량과 유효선량은 2번 Ion chamber 설정 시 가장 낮게 나타났으며, 1번 Ion chamber 설정 시 가장 높게 나타났다. MTF 결과는 관전압 120 kVp, 2번 Ion chamber를 설정 시 가장 우수하게 나타났다. 따라서 DR을 이용한 흉부 우측 측와위 촬영 시 화질의 저하 없이 피폭선량을 효과적으로 감소시키며 우수한 영상을 획득할 수 있는 최적의 조합은 관전압 120 kVp와 2번 Ion chamber를 설정하는 것이다.
Objective : This study was performed to evaluate and compare the efficacies of caudal epidural injections performed at prone and lateral decubitus positions. Methods : A total of 120 patients suffering from low back pain and radicular leg pain were included and patients were randomly distributed into 2 groups according to the position during injection. In Group 1 (n=60; 32 women, 28 men), caudal epidural injection was performed at prone position, whereas it was implemented at lateral decubitus position in Group 2 (n=60; 33 women, 27 men). Visual analogue scale, Oswestry Disability Index (ODI), walking tolerance (WT) and standing tolerance (ST) were compared in 2 groups before and after injection. Results : In Group 1, ODI values were higher at 30th minute (p=0.007), 3rd week (p=0.043) and 6th month (p=0.013). In Group 1, ODI, VAS and ST values were improved significantly at all follow-up periods compared to initial values. In Group 1, WT scores were better than initial values at 30th minute, 3rd week and 3rd month. In Group 2, ODI scores at 30th minute, 3rd week, 3rd month and 6th month were improved while VAS and ST scores were improved at all periods after injection. WT scores were better at 30th minute, 3rd week and 3rd month compared to initial WT scores. Conclusion : Our results indicated that application of injection procedure at lateral decubitus position allowing a more concentrated local distribution may provide better relief of pain.
Thoracoscopic esophagectomy for esophageal cancer can be performed in multiple positions, such as the lateral decubitus position or prone position, using various techniques. Each approach has its own advantages and disadvantages, and surgeons can select an appropriate approach based on their preferences. Except for the reduction of pulmonary complications, the benefits of thoracoscopic esophagectomy, including oncologic outcomes, have not been proven scientifically. This review describes the approaches and procedures of thoracoscopic esophagectomy and presents scientific evidence for this procedure.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.