• 제목/요약/키워드: Lateral Damper

검색결과 96건 처리시간 0.028초

Tuned mass dampers for torsionally coupled systems

  • Pansare, A.P.;Jangid, R.S.
    • Wind and Structures
    • /
    • 제6권1호
    • /
    • pp.23-40
    • /
    • 2003
  • The steady state response of a torsionally coupled system with tuned mass dampers (TMDs) to external wind-induced harmonic excitation is presented. The torsionally coupled system is considered as one-way eccentric system. The eccentricity considered in the system is accidental eccentricity only. The performance of single tuned mass damper (TMD) optimally designed without considering the torsion is investigated for the torsionally coupled system and found that the effectiveness of a single TMD is significantly reduced due to torsion in the system. However, the design of TMD system without considering the torsion is only justified for torsionally stiff systems. Further, the optimum parameters of a single TMD considering the accidental eccentricity are obtained using numerical searching technique for different values of uncoupled torsional to lateral frequency ratio and aspect ratio of the system. The optimally designed single TMD system is found to be less effective for torsionally coupled system in comparison to uncoupled system. This is due to the fact that a torsionally coupled system has two natural frequencies of vibration, as a result, at least two TMDs are required which can control both lateral and torsional response of the system. The optimum damper parameters of different alternate arrangements such as (i) two identical TMDs placed at opposite corners, (ii) two independent TMDs and (iii) four TMDs are evaluated for minimum response of the system. The comparative performance of the above TMDs arrangements is also studied for both torsionally coupled and uncoupled systems. It is found that four TMDs arrangement is quite effective solution for vibration control of torsionally coupled system.

Buffeting response control of a long span cable-stayed bridge during construction using semi-active tuned liquid column dampers

  • Shum, K.M.;Xu, Y.L.;Guo, W.H.
    • Wind and Structures
    • /
    • 제9권4호
    • /
    • pp.271-296
    • /
    • 2006
  • The frequency of a traditional tuned liquid column damper (TLCD) depends solely on the length of liquid column, which imposes certain restrictions on its application to long span cable-stayed bridges during construction. The configuration of a cable-stayed bridge varies from different construction stages and so do its natural frequencies. It is thus difficult to apply TLCD with a fixed configuration to the bridge during construction or it is not economical to design a series of TLCD with different liquid lengths to suit for various construction stages. Semi-active tuned liquid column damper (SATLCD) with adaptive frequency tuning capacity is studied in this paper for buffeting response control of a long span cable-stayed bridge during construction. The frequency of SATLCD can be adjusted by active control of air pressures inside the air chamber at the two ends of the container. The performance of SATLCD for suppressing combined lateral and torsional vibration of a real long span cable-stayed bridge during construction stage is numerically investigated using a finite element-based approach. The finite element model of SATLCD is also developed and incorporated into the finite element model of the bridge for predicting buffeting response of the coupled SATLCD-bridge system in the time domain. The investigations show that with a fixed container configuration, the SATLCD with adaptive frequency tuning can effectively reduce buffeting response of the bridge during various construction stages.

Tuned liquid column dampers with adaptive tuning capacity for structural vibration control

  • Shum, K.M.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.543-558
    • /
    • 2005
  • The natural frequencies of a long span bridge vary during its construction and it is thus difficult to apply traditional tuned liquid column dampers (TLCD) with a fixed configuration to reduce bridge vibration. The restriction of TLCD imposed by frequency tuning requirement also make it difficult to be applied to structure with either very low or high natural frequency. A semi-active tuned liquid column damper (SATLCD), whose natural frequency can be altered by active control of liquid column pressure, is studied in this paper. The principle of SATLCD with adaptive tuning capacity is first introduced. The analytical models are then developed for lateral vibration of a structure with SATLCD and torsional vibration of a structure with SATLCD, respectively, under either harmonic or white noise excitation. The non-linear damping property of SATLCD is linearized by an equivalent linearization technique. Extensive parametric studies are finally carried out in the frequency domain to find the beneficial parameters by which the maximum vibration reduction can be achieved. The key parameters investigated include the distance from the centre line of SATLCD to the rotational axis of a structure, the ratio of horizontal length to the total length of liquid column, head loss coefficient, and frequency offset ratio. The investigations demonstrate that SATLCD can provide a greater flexibility for its application in practice and achieve a high degree of vibration reduction. The sensitivity of SATLCD to the frequency offset between the damper and structure can be improved by adapting its frequency precisely to the measured structural frequency.

제진장치를 적용한 초고층 주거형 건축물의 횡변위 제어 성능 평가 (Performance Evaluation of the Drift Control in Residential Tall Building Using the Dampers)

  • 박지형;김태호;김욱종;이도범
    • 한국전산구조공학회논문집
    • /
    • 제21권3호
    • /
    • pp.265-273
    • /
    • 2008
  • 최근 급속하게 증가하고 있는 초고층 건축물은 바람이나 지진에 의한 횡변위를 효율적으로 제어하는 기술이 매우 중요하다. 그러나 국내의 초고층 주거형 건축물에 주로 사용되는 횡력 저항 구조시스템인 아웃리거 시스템은 별도의 공간을 요구하여 시공이 어렵고 공사 기간이 오래 걸리는 등의 불리한 점들이 있다. 반면 근래에 사용되고 있는 제진 시스템은 동적 하중에 의한 진동에너지를 부가적인 제진장치에 집중시킴으로써 건물의 횡변위를 저감시키며, 댐퍼의 설치도 비교적 용이하다. 또한, 아웃리거 설치와 같은 횡변위 제어시스템은 강성증가로 인해 풍응답이 증가되어 거주자의 불편과 같은 사용성 문제가 발생하기도 하며 이는 다른 추가적인 제어방식을 요구하게 된다. 따라서 본 연구에서는 초고층 주거형 건축물에 대한 횡변위를 효과적으로 제어하면서 아웃리거시스템을 대체 또는 보완할 수 있는 새로운 방법으로써 다양한 제진장치를 적용하여 각각의 횡변위제어 성능을 검토해보았다.

고속열차의 주행동특성 개선에 관한 연구 (A study on the Dynamic Behavior Enhancement of the Korean High-speed Train)

  • 전창성
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.81-87
    • /
    • 2017
  • 본 연구는 고속열차 시운전 시험과 이에 따른 주행동특성 고찰 및 개선에 관한 것이다. 고속열차 시운전 시험을 통한 선행 연구에서 도출한 요댐퍼 설치 방법에 따른 후미 진동 개선 방안을 실제 고속철도 차량의 시운전시에 적용하여 후미 진동 저감 효과가 있음을 확인하였다. 또한 전체 차량에 대한 진동저감 방안을 동역학 해석 소프트웨어를 사용하여 수치 해석적 방법으로 도출하였으며, 그 효과를 시운전 시험을 통하여 확인하였다. 개선된 설계안은 실제 2층 고속열차 객차에 적용되어 주행동특성 문제없이 시운전을 진행하였다. 차세대 고속열차 임계속도에 영향을 미치는 현가장치 파라미터들에 대한 민감도 분석을 수행하였으며, 임계속도에 크게 영향을 미치는 4개의 설계변수를 도출하였는데, 이는 1차 탄성조인트 열차진행 방향 강성, 2차 요댐퍼 시리즈 강성, 2차 횡댐퍼 댐핑계수, 차간 댐퍼 댐핑계수 순이었다. 이 설계변수에 대한 최적화를 통하여 임계속도를 23.3% 향상시키는 현가장치 파라미터를 제시하였으며, 이는 차세대 고속열차 상용화 모델의 설계에 이용될 수 있다.

Analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers

  • Huang, Xiaogang;Zhou, Zhen;Zhu, Dongping
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.355-366
    • /
    • 2019
  • Self-centering wall (SCW) is a resilient and sustainable structural system which incorporates unbonded posttensioning (PT) tendons to provide self-centering (SC) capacity along with supplementary dissipators to dissipate seismic energy. Hysteretic energy dissipators are usually placed at two sides of SCWs to facilitate ease of postearthquake examination and convenient replacement. To achieve a good prediction for the skeleton curve of the wall, this paper firstly developed an analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers (VD-SCWs) using the concept of elastic theory. A simplified method for the calculation of limit state points is developed and validated by experimental results and can be used in the design of the system. Based on the analytical results, parametric analysis is conducted to investigate the influence of damper and tendon parameters on the performance of VD-SCWs. The results show that the proposed approach has a better prediction accuracy with less computational effects than the Perez method. As compared with previous experimental results, the proposed method achieves up to 60.1% additional accuracy at the effective linear limit (DLL) of SCWs. The base shear at point DLL is increased by 62.5% when the damper force is increased from 0kN to 80kN. The wall stiffness after point ELL is reduced by 69.5% when the tendon stiffness is reduced by 75.0%. The roof deformation at point LLP is reduced by 74.1% when the initial tendon stress is increased from $0.45f_{pu}$ to $0.65f_{pu}$.

철도차량 이차현가장치 댐퍼 매개변수 변화에 따른 고유모드 특성에 대한 연구 (A Study on the Eigenmode Characteristics by Changing Damping Parameters of Secondary Suspension (Damper) on Railway Vehicles)

  • 신유정;유원희;박준혁;허현무
    • 한국정밀공학회지
    • /
    • 제28권7호
    • /
    • pp.796-804
    • /
    • 2011
  • Railway vehicles are capable of indicating several types of instability. This phenomenon, which is called hunting motion, is a self excited lateral oscillation that is caused by the running velocity of the vehicle and wheel frail interactive forces. The interactive forces act to change effectively the damping characteristics of railway vehicle systems. This paper will show the impact of instability on the transfer function behavior using damping characteristics of secondary suspension. The vehicle dynamics are modeled using a 17 degree of freedom considering linear wheel/rail contact. The paper deals with certain condition of the damper characteristics that one is about various damping coefficient and another is equipped damper direction.

진동대 실험을 통한 강골조 구조물에 설치된 점탄성 감쇠기의 성능평가 (Performance Evaluation of Viscoelastic Dampers installed in the Steel Frame Structures Using the shaking table set)

  • 김진구;서현수;권민호;임정희;김진섭
    • 복합신소재구조학회 논문집
    • /
    • 제7권1호
    • /
    • pp.32-38
    • /
    • 2016
  • It has been many efforts for reinforcement of existing structure since the number of earthquake has been increased world widely. Especially the occurrence of earthquake surrounding area of Korean peninsular is dramatically increased. Since the buildings in Korea have not been designed to carry the lateral and shear force caused by earthquake, the building will experience massive damages even under moderate earthquake. For this reason, the viscoelastic damper is proposed in this paper to enhance the earthquake resistance of a steel frame buildings. The viscoelastic dampers have been able to increase the overall damping of the structure significantly, hence improving the overall performance of dynamically sensitive structures. In this paper, Viscoelastic dampers designed are consists of FRP panel and viscoelastic material. In this paper, evaluate the performance of the viscoelastic damper through the experiment.

Seismic performance enhancement of a PCI-girder bridge pier with shear panel damper plus gap: Numerical simulation

  • Andika M. Emilidardi;Ali Awaludin;Andreas Triwiyono;Angga F. Setiawan;Iman Satyarno;Alvin K. Santoso
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.69-82
    • /
    • 2024
  • In the conventional seismic design approach for a bridge pier, the function of the stopper, and shear key are to serve as mechanisms for unseating prevention devices that retain and transmit the lateral load to the pier under strong earthquakes. This frequently inflicts immense shear forces and bending moments concentrated at the plastic hinge zone. In this study, a shear panel damper plus gap (SPDG) is proposed as a low-cost alternative with high energy dissipation capacity to improve the seismic performance of the pier. Therefore, this study aimed to investigate the seismic performance of the pre-stressed concrete I girder (PCI-girder) bridge equipped with SPDG. The bridge structure was analyzed using nonlinear time history analysis with seven-scaled ground motion records using the guidelines of ASCE 7-10 standard. Consequently, the implementation of SPDG technology on the bridge system yielded a notable decrease in maximum displacement by 41.49% and a reduction in earthquake input energy by 51.05% in comparison to the traditional system. This indicates that the presence of SPDG was able to enhance the seismic performance of the existing conventional bridge structure, enabling an improvement from a collapse prevention (CP) level to an immediate occupancy (IO).

한국형고속열차 세미액티브 진동 제어 (Semi-Active Vibration Control for HSR 350x)

  • 김상수;김영국;김기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.169-173
    • /
    • 2007
  • To improve the riding comfort and to increase the speed of high-speed railway, it needs active suspension system for railway more and more. In Korea, Korean Train Express (KTX) was opened to commercial traffic 3years ago. Korea High-speed Railway (HSR 350x) was developed and succeeded 350km/h test run by Korean government and several related institute. With the increase of the speed, the vibration control of the high-speed railway becomes important to improve high ride quality. To meet this request, the authors suggest the installation of lateral semi-active damper to the power car of HSR 350x. The result shows better performance.

  • PDF