• 제목/요약/키워드: Latent heat storage system

검색결과 95건 처리시간 0.021초

LNG 냉열활용을 위한 열교환기의 배열 형태가 냉동창고 성능에 미치는 연구 (Effect of the Array Type of Heat Exchangers on Performance of Refrigerated Warehouse for Utilization of LNG Cold Energy)

  • 한단비;김윤지;변현승;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.282-288
    • /
    • 2019
  • When liquefied natural gas (LNG) is vaporized to form natural gas for industrial and household consumption, a tremendous amount of cold energy is transferred from LNG to seawater as a part of the phase-change process. This heat exchange loop is not only a waste of cold energy, but causes thermal pollution to coastal fishery areas by dumping the cold energy into the sea. This project describes an innovative new design for reclaiming cold energy for use by cold storage warehouses (operating in the 35 to $62^{\circ}C$ range). Conventionally, warehouse cooling is done by mechanical refrigeration systems that consume large amounts of electricity for the maintenance of low temperatures. Here, a closed loop LNG heat exchange system was designed (by simulator) to replace mechanical or vapor-compression refrigeration systems. The software PRO II with PROVISION V9.4 was used to simulate LNG cold energy, gas re-liquefaction, and the vaporized process under various conditions. The effects on sensible and latent heats from changes to the array type of heat exchangers have been investigated, as well as an examination of the optimum.

수소액화공정에서 LNG 냉열 적용에 관한 시뮬레이션 연구 (Simulation Study on the Application of LNG Cold Energy for Hydrogen Liquefaction Process)

  • 한단비;변현승;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.33-40
    • /
    • 2020
  • As hydrogen utilization becomes more active recently, a large amount of hydrogen should be supplied safely. Among the three supply methods, liquefied hydrogen, which is an optimal method of storage and transportation convenience and high safety, has a low temperature of -253℃, which is complicated by the liquefaction process and consumes a lot of electricity, resulting in high operating costs. In order to reduce the electrical energy required for liquefaction and to raise the efficiency, hydrogen is cooled by using a mixed refrigerant in a precooling step. The electricity required for the precooling process of the mixed refrigerant can be reduced by using the cold energy of LNG. Actually, LNG cold energy is used in refrigeration warehouse and air liquefaction separation process, and a lot of power reduction is achieved. The purpose of this study is to replace the electric power by using LNG cold energy instead of the electric air-cooler to lower the temperature of the hydrogen and refrigerant that are increased due to the compression in the hydrogen liquefaction process. The required energy was obtained by simulating mixed refrigerant (MR) hydrogen liquefaction system with LNG cold heat and electric system. In addition, the power replacement rate of the electric process were obtained with the pressure, the temperature of LNG, the rate of latent heat utilization, and the hydrogen liquefaction capacity, Therefore, optimization of the hydrogen liquefaction system using LNG cold energy was carried out.

수직원통형 빙축열조내 외향용융과정시 열전달특성에 관한 연구 -작동유체의 유동방향 및 축열조 형상비에 따른 열성능 비교- (A study on the heat transfer characteristics during outward melting process of ice in a vertical cylinder)

  • 김동환;김동춘;김일경;김영기;임장순
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.171-179
    • /
    • 1997
  • During the day time in summer, peak of air conditing load, and electric power management system lies under overloaded condition. The reason is the enlarged peak load value of electric power caused by increased air-cooling load in summer. To prevent load concentration during day time and overloaded condition of power management system, some energy storage methods are suggested. One of these methods is ice storage system. Water has some good properties as P.C.M.(Phase Chang Material) : Its melting point is the range of required operation temperature. It has large specific latent heat and is chemically stable compared to other organic or inorganic substances. It is cheap and easy to treat. This study represents experimental results of heat transfer characteristics of P.C.M. under the outward melting process in a vertical cylinder. We experimented with twelve combinations of conditions, i.e., three different inlet temperatures($7^{\circ}C,\;4^{\circ}C\;and\;1^{\circ}C$), two working fluid directions(upward and downward), and two aspect ratios, H/R(4 and 2). At the inlet temperature of $7^{\circ}C$ and $4^{\circ}C$, there was temperature stagnation region where the temperature of P.C.M. remains constant at $4^{\circ}C$ regardless of aspect ratio and direction of working fluid. This temperature stagnation occurs as the water, at its maximum density, flows down to the lower region. The phase change interface formed bell-shaped curve as the melting process continued. With a new set of conditions(4H/R, inlet temperature $4^{\circ}C$ and $1^{\circ}C$, downward/upwerd inlet direction), the movement of phase change interface was faster when the working flued inlet direction was downward. With the same set of conditions, melting rate and total melting energy were larger when the working fluid inlet direction was downward. The results were reversed when the other sets of conditions were applied.

  • PDF

아이스슬러리형 축냉시스템을 이용한 쇼케이스 냉각장치의 열적성능에 관한 실험적 연구 (Thermal Performance of the Show-Case Cooler Using Ice Slurry Type Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.26-29
    • /
    • 2011
  • 일반적인 냉각 과정에 적용되는 이차 냉매로서 아이스슬러리 적용 기술이 최근 개발되고 있다. 아이스슬러리는 액체와 거의 동일한 특성을 가지고 있고, 단위 체적당 아이스슬러리의 에너지용량이 얼음 입자의 잠열로 인해 냉각수나 브라인에 비해 상당히 높지만 파이프를 통해서 잘 유동시킬 수 있다. 아이스슬러리를 적용하는 냉각시스템의 설계를 위한 기초 결과를 제시하기 위하여, 쇼케이스의 냉각 코일에 아이스슬러리를 적용하는 실험을 수행하였다. 냉각 코일 입구에서의 아이스슬러리의 온도가 R22에 비하여 적어도 $5^{\circ}C$ 정도 높지만, R22를 적용하는 냉각시스템에 비하여 동등한 열적 성능을 가지고 있었다.

광릉 산림의 플럭스 자료 처리와 품질 관리 (Processing and Quality Control of Flux Data at Gwangneung Forest)

  • 임희정;이영희
    • 한국농림기상학회지
    • /
    • 제10권3호
    • /
    • pp.82-93
    • /
    • 2008
  • 보다 자동화된 방법으로 신뢰성 있는 난류 플럭스의 자료를 생산하기 위해서 Hong and Kim(2002)의 난류 품질 관리 프로그램을 개선하고 개선된 프로그램을 광릉산림에 적용하여 복잡한 산림지역에서 난류 플럭스의 특성을 조사하였다. 개선된 프로그램을 이용하여 2005년 1월부터 5월까지 광릉 수목원에 위치한 주 타워의 두 고도(20m와 40m)에서 관측된 난류 자료에 대하여 품질 검사를 실시하였다. 개선전과 비교해 개선된 프로그램은 이상점(outlier)에 해당되는 자료들을 많이 제거하였다. 자료의 품질체계는 4등급(Good, Dubious, Missing, Bad)으로 분류하였으며 본 분석에서 사용된 기간의 자료 중 25%는 결측이었고(Missing 등급), 60%는 Good 등급으로 분류되었다. 고도 별로는 40m에서 관측된 자료가 20m에서 관측된 자료보다 Bad 등급의 자료수가 적었는데 이는 20m가 식생 꼭대기에 인접한 거칠기 아층에 해당하고 또한 풍속도 더 낮은데 기인한다. Bad 등급으로 분류된 자료의 주원인은 낮은 풍속으로 나타났다. 분석 기간 동안의 에너지 수지의 닫힘은 약 40%로 나타났고 이러한 에너지 불균형의 부분적인 이유로는 열 저장항들이 고려되지 않은 점, 토양열 플럭스 측정의 불확실성, 복잡한 지형 등에 의한 국지풍에 의한 이류 등이 복합적으로 작용했을 것으로 생각된다. 광릉에서 발생하는 상향 운동량 플럭스는 국지풍의 발달 시 높은 발생률을 보여 이 둘이 밀접히 관련되어 있음을 나타낸다. 야간에 낮은 음의 $CO_2$ 플럭스가 발생하는 경우에 대하여 평균 시간을 증가시킴에 따른 $CO_2$ flux의 변화를 조사한 결과 평균시간이 10분 이상 증가함에 따라 $CO_2$ flux의 절대값이 빠르게 증가하는 경향을 보였다. 이는 야간에 $CO_2$ 플럭스는 중규모 운동이나 비정상성(nonstationarity) 등의 영향을 많이 받고 있음을 시사한다. 그러므로 야간에 보다 정확한 난류 플럭스 값을 산출하기 위해서는 평균시간의 적절한 조절이 필요할 것으로 보인다.