• Title/Summary/Keyword: Laser-induced bubble

Search Result 17, Processing Time 0.02 seconds

An Experimental Study on the Flow Characteristics in Highly Viscous Liquid by Multi-Nozzle Bubbling (고점성 액체 내부에서의 다중 노즐 버블링에 의한 유동특성에 대한 실험적 연구)

  • Kim, Hyun-Dong;Ryu, Seung-Gyu;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.195-201
    • /
    • 2007
  • A visualization study of flow characteristics in a mixer using multi-nozzle bubbling was performed. The mixer is filed with liquid glycerin (dynamic viscosity = $1000mPa{\cdot}s\;at\;25^{\circ}C$) and convective mixing is induced by air bubbles generated from 9 orifices installed on the bottom of the mixer. To visualize the flow field, PIV (Particle Image Velocimetry) system consisting of 532nm Nd:YAG laser, $2k{\times}2k$ CCD camera and synchronizer is adopted. The bubbles generated with uniform size and frequency form bubble stream and bubble streams rise vertically without interaction between bubble streams. Mixing efficiency is affected by the height of bubbler and the effective height of bubbler is 20nm from the bottom of the mixer.

Flow Visualization and PIV Measurement of Multiphase Flow in Highty Viscous Liquid (고점성 유체 내부에서의 다상유동장 가시화 및 PIV 측정)

  • Kim, Hyun-Dong;Ryu, Seung-Gyu;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.48-54
    • /
    • 2006
  • A visualization study of flow characteristics in a mixer using multi-nozzle bubbling was performed. The mixer is filled with liquid glycerin (dynamic viscosity = $1000mPa{\cdot}$ s at $25^{\circ}C$) and convective mixing is induced by air bubbles generated from 9 orifices installed on the bottom of the mixer. To visualize the flow field, PIV (Particle Image Velocimetry) system consisting of 532nm Nd:YAG laser, $2k\times2k$ CCD camera and synchronizer is adopted. The bubbles generated with uniform size and frequency form bubble stream, and bubble streams rise vertically without interaction between bubble streams. Mixing efficiency is affected by the height of bubbler and the effective height of bubbler is 20mm from the bottom of the mixer.

  • PDF

Generation of sub-micron (nano) bubbles and characterization of their fundamental properties

  • Kim, Sangbeom;Kim, Hyoungjun;Han, Mooyoung;Kim, Tschungil
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.382-388
    • /
    • 2019
  • Although nanobubbles attract significant attention, their characteristics and applications have not been thoroughly defined. There are diverse opinions about the definition of nanobubbles and controversy regarding methods that verify their characteristics. This study defines nanobubbles as having a size less than $1{\mu}m$. The generation of these sub-micron (nano) bubbles may be verified by induced coalescence or light scattering. The size of a sub-micron (nano) bubbles may be measured by optical, and confocal laser scanning microscopy. Also, the size may be estimated by the relationship of bubble size with the dissolved oxygen concentration. However, further research is required to accurately define the average bubble size. The zeta potential of sub-micron (nano) bubbles decreases as pH increases, and this trend is consistent for micron bubbles. When the bubble size is reduced to about 700-900 nm, they become stationary in water and lose buoyancy. This characteristic means that measuring the concentration of sub-micron (nano) bubbles by volume may be possible by irradiating them with ultrasonic waves, causing them to merge into micron bubbles. As mass transfer is a function of surface area and rising velocity, this strongly indicates that the application of sub-micron (nano) bubbles may significantly increase mass transfer rates in advanced oxidation and aeration processes.

The Weldability of $6mm^t$ Primer-coated Steel for Shipbuilding Using $CO_2$ Laser (II) - Dynamic Behavior of Laser Welding Phenomenon and Composition of Porosity and Vaporized-particle - ($6mm^t$조선용 프라이머 코팅강판의 $CO_2$레이저 용접성 (II) - 레이저 용접현상의 동적거동과 기공 및 증발입자의 조성 -)

  • Kim, Jong-Do;Park, Hyun-Joon
    • Journal of Welding and Joining
    • /
    • v.24 no.2
    • /
    • pp.71-78
    • /
    • 2006
  • It has been reported that good quality weld beads are not easily obtained during the $CO_2$ CW laser welding of primer coated plate. However, by introducing a small gap clearance in the lap position, the zinc vapor can escape through it and sound weld beads can be acquired. Therefore, this study examines for keyhole behavior by observing the laser-induced plasma and investigates the relation between keyhole behavior and formation of weld defect. Laser-induced plasma has accompanied with the vaporizing pressure of zinc ejecting from keyhole to surface of primer coated plate. This dynamic behavior of plasma was very unstable and this instability was closely related to the unstable motion of keyhole during laser welding. As a result of observing the composition of porosity, much of Zn element was found from inner surface of porosity. But Zn was not found from the dimple structure fractured at the weld metal. By analyzing of vaporizing element in laser welding, a component ratio of Zn was decreased by introducing a small gap clearance. Therefore we can prove that the major cause of porosity is the vaporization of primer in lap position. Mechanism of porosity-formation is that the primer vaporized from the lap position accelerates dynamic behavior of the key hole and the bubble separated from the key hole is trapped in the solidification boundary and romaines as porosity.

Fabrication of Titanium Microchannels by using Ar+ Laser-assited Wet Etching (레이저 유도에칭을 이용한 티타늄 미세채널 제조)

  • 손승우;이민규;정성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.709-713
    • /
    • 2004
  • Characteristics of laser-assisted wet etching of titanium in phosphoric acid were investigated to examine the feasibility of this method for fabrication of high aspect ratio microchannels. Laser power, number of scans, etchant concentration, position of beam waist and scanning speed were taken into consideration as the major process parameters exerting the temperature distribution and the cross sectional profile of etched channels. Experimental results indicated that laser power influences on both etch width and depth while number of scans and scanning speed mainly affect on the etch depth. At a low etchant concentration, the cross sectional profile of an etched channel becomes a U-shape but it gradually turns into a V-shape as the concentration increases. On the other hand, surface of the laser beam focus with respect to the sample surface is found to be a key factor determining the bubble dynamics and thus the process stability. It is demonstrated that metallic microchannels with different cross sectional profiles can be fabricated by properly controlling the process parameters. Microchannels of aspect ratio up to 8 with the width and depth ranges of 8∼32 m and 50∼300 m, respectively, were fabricated.

  • PDF

THE EFFECT OF $CO_2$ LASER IRRADIATION ON ENAMEL SURFACE AND THE BOND STRENGTH OF SEALANT MATERIAL (탄산가스 레이저 조사가 법랑질 표면구조와 치면열구 전색재의 결합강도에 미치는 효과)

  • Yun, Dong-Sik;Kim, Yong-Kee;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.761-771
    • /
    • 1998
  • In this study, attempt has been made to evaluate the effect of $CO_2$ laser irradiation on enamel surface structure and the bond strength of sealant material. Conventional acid etching was used as a control technic for comparison. The results obtained from this experiment were as follows; 1. The highest mean shear bond strength value was observed in samples of Group I (acid-etching) with the statistical significance(p<.05) between all the other groups. 2. The shear bond strength in Group IV was the lowest among laser etching groups. but there were no significant difference between them(p>.05). 3. Scanning electron microscopic observation showed that the rough and irregular surface was created by $CO_2$ laser treatment with the formation of numerous pores, micro-cracks, and small bubble-like inclusion. Increasing the energy density induced localized surface melt with a thin smooth glaze-like appearance. 4. In acid-etched control specimen cohesive failure predominated, whereas adhesive failure was the main mode in laser-treated group. Based upon the above-mentioned results, it can be assumed that the $CO_2$ laser is not an adequate substitute for the acid-etch technique in enamel preconditioning. More studies are required to explore the effective condition of laser irradiation which could attain the better bond strength of restorative materials.

  • PDF

Development and application of non-invasive drug delivery systems utilizing pulse power, and its application to mouse models (펄스파워를 적용한 비침습 약물 전달기 개발 및 마우스 모델로의 적용)

  • Hwi-Chan Ham;Kyu-Sik Kim;Ji-Hwan Lee;Hyung-Jin Choi;Do-Nyun Kim;Jai-Ick Yoh
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2024
  • Some drugs can offer far better medical effectiveness as it is injected through the intradermal layer of the skin, known as a needle-free injection. However, conventional needle-free devices might deliver a relatively large amount of drug in a just single spot of skin, splitting open the tissue layer structure, which might cause bruising and bleeding. By injecting the small volume with a fast repetition rate in a large surface area of skin, the patient may get much fewer injuries and pain. To achieve that specification, the driving force must be instantaneous and short-pulsed. Such a form of an injection device has been developed but the efficacy of those devices has been rarely examined. Therefore, this study developed the laser-induced microjet device that ejects microjet whose speed is ~310 m/s, during the 400~800 ㎲ of pulse time. The device can eject ~1 µL of the drug at the rate at which each shot repeated 10 shots per second. Using this specification, we evaluated the efficacy of drug injection onto mouse models. After injecting the insulin solution into the mouse model, the blood insulin level is detected, resulting in 20 % of blood insulin level with the ordinary needle syringe injection method.