• Title/Summary/Keyword: Laser treatment

Search Result 1,148, Processing Time 0.033 seconds

Various clinical use of laser in esthetic treatment (심미치료에 레이저를 활용한 다양한 임상적용)

  • Eun, Hee-Jong
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.376-384
    • /
    • 2018
  • The most valuable site of laser treatment is analgesic effect and fast healing process. If we understand an use this advantage correctly, it will helpful in relationship with patients and hospital management. So this study reported clinical cases about laser used in esthetic treatment with literature review. Periodontal treatment using laser was taken for patient who complain about gingival swelling during orthodontic treatment. And, esthetic plastic treatment using laser for alveoar reduction was taken for patient who complained about esthetic problem of maxillary gingiva. The treatment using laser can shorten the inconvenience and complicated treatment process and minimize patient's fear and discomfort during treatment procedure. So patients and clinicians can expect competent result in clinical cases. The laser for esthetic treatment was valuable.

  • PDF

Current concepts of Laser dentistry (임상가를 위한 특집2 - Current concepts of Laser dentistry)

  • Eun, Hee-Jong
    • The Journal of the Korean dental association
    • /
    • v.49 no.11
    • /
    • pp.670-678
    • /
    • 2011
  • Various sorts of dental devices for the dental treatment have been introduced and adopted during past several years. Dental Laser, among all devices, seems to be possible for applying to over the whole treatments and widely employed. Furthermore, this article is to introduce that Dental Laser is intended to care patients secured with the effectual treatment against Conventional procedures based upon its studies. The advantages of Dental Laser treatment-along with LLLT (Low Level Laser Therapy) effect, biostimulation effect, and minimal invasive technique - make the patients reduce their fear of the operation, lighten the inconvenience of post operation, and shorten the treatment period. In particular, it is worth considering that the use of laser-assisted therapies is associated with a marked reduction in the use of analgesics and anti-inflammatory medications compared with conventional procedures. This article is to state advantages and differences of Dental Laser treatment compared with Conventional procedures, and to emphasize to become well-acquainted with the precautions for safety and effective Dental Laser treatment. In case of operating Dental Laser with lack of the instructions, it will cause the unpredicted fatal results; therefore this treatment requires special care in its operation. Henceforward, it is anticipated that infinite treatment protocols will be introduced by applying Dental Laser, and this is to address the utilization of Dental Laser.

Heat Treatment Characteristics of a Press Draw Mold by Using High Power Diode Laser (고출력 다이오드 레이저를 이용한 프레스 드로우금형의 열처리 특성)

  • Hwang, Hyun-Tae;So, Sang-Woo;Kim, Jung-Do;Kim, Young-Kuk;Kim, Byeong-Hun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.6
    • /
    • pp.339-344
    • /
    • 2009
  • Recently, Laser surface treatment technologies have been used to improve wear charactenitics and fatigue resistance of metal molding. When the laser beam is irradiated on the surface and laser speed is appropriate, the laser focal position is rapidly heated and the thermal energy of surface penetrates the material after irradiation, finally imbuing it with a new mechanical characteristic by the process of self-quenching. This research estimates the material characteristic after efficient and functional surface treatment using HPDL, which is more efficient than the existing CW Nd:YAG laser heat source. To estimate this, microstructural changes and hardness characteristics of three parts (the surface treatment part, heat affect zone, and parental material) are observed with the change of laser beam speed and surface temperature. Moreover, the depth of the hardened area is observed with the change of the laser beam speed and temperature. From the results of the experiments, it has been shown that the maximum hardness is approximately 788Hv when the heat treatment temperature and the travel speed are $1150^{\circ}$ and 2 mm/sec, respectively.

Investigation of Glass Substrate Sealing for ECL Application using Laser Welding Technology (레이저 웰딩 기술을 이용한 ECL용 유리 기판 접합에 대한 고찰)

  • Sung, Youl-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.28-32
    • /
    • 2015
  • In this work, we reported fabrication of sealing the glass substrate using laser treatment at low temperature for electrochemical luminescence (ECL) cell. The laser treatment at temperature is using laser diode. The glass substrate sealing by laser treatment tested at 3-10W, 2-5 mm/s for build and tested. The sealing laser treatment method will allow associate coordination between the two glass substrate was enclosed. The effect of laser treatment to sealing the glass substrate was found to have cracks and air gap at best thickness of about 550-600 im for condition 3 W, 3 mm/s. The surface of sealing was roughness which was not influent to electrodes It can reduce the cracks, crevices and air gaps as well, improves the performance viscosity in butter bus bar electrodes. Therefore, it is more effective viscosity between two FTO glasses substrate.

In Vivo and Ex Vivo Skin Reactions after Multiple Pulses of 1,064-nm, Microlens Array-type, Picosecond Laser Treatment

  • Lyu, Herin;Park, Jinyoung;Lee, Hee Chul;Lee, Sang Ju;Kim, Young Koo;Cho, Sung Bin
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.142-149
    • /
    • 2020
  • Background and Objectives A picosecond-domain laser treatment using a microlens array (MLA) or a diffractive optical element elicits therapeutic micro-injury zones in the skin. This study examined the patterns of tissue reactions after delivering multiple pulses of 1,064-nm, MLA-type, picosecond neodymium:yttrium-aluminum-garnet laser treatment. Materials and Methods Multiple pulses of picosecond laser treatment were delivered to ex vivo human or brown micropig skin and analyzed histopathologically. A high-speed cinematographic study was performed to visualize the multiple pulses of picosecond laser energy-induced skin reactions in in vivo human skin. Results In the ex vivo human skin, a picosecond laser treatment at a fluence of 0.3 J/cm2 over 100 non-stacking passes generated multiple lesions of thermally-initiated laser-induced optical breakdown (TI-LIOB) in the epidermis and dermis. In the ex vivo micropig skin, stacking pulses of 20, 40, 60, 80, and 100 at a fluence of 0.3 J/cm2 generated distinct round to oval zones of tissue coagulation in the mid to lower dermis. High-speed cinematography captured various patterns of twinkling, micro-spot reactions on the skin surface over 100 stacked pulses of a picosecond laser treatment. Conclusion Multiple pulses of 1,064-nm, MLA-type, picosecond laser treatment elicit marked TI-LIOB reactions in the epidermis and areas of round to oval thermal coagulation in the mid to deep dermis.

The Low Temperature Laser Treatment of Sealing Glass Substrate for ECL (ECL용 유리기판의 레이저 저온 실링처리)

  • Choi, Hye-Su;Park, Cha-Soo;Gwak, Dong-Joo;Sung, Youl-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1134-1135
    • /
    • 2015
  • In this paper, we reported fabrication of sealing the glass substrate using laser treatment at low temperature for electrochemical luminescence (ECL) cell. The laser treatment at temperature is using laser diode. The glass substrate sealing by laser treatment tested at 1-5 W, 1-5 mm/s for builted and tested. The sealing laser treatment method will allow associate coordination between the two glass substrate was enclosed. The effect of laser treatment to sealing the glass substrate was found to have cracks and air gap at best thickness of about $845-780{\mu}m$ for condition 5 W, 1-5 mm/s. The surface of sealing was roughness which was not influent to electrodes So, it is more effective viscosity between two glasses substrate.

  • PDF

Heat Treatment Characteristics of Press Blanking Die by Using High Power Diode Laser (고출력 다이오드 레이저를 이용한 프레스 전단금형의 경화특성)

  • Hwang, Hyun-Tae;So, Sang-Woo;Hwang, Jae-Hyun;Kim, Jong-Do
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.257-262
    • /
    • 2010
  • Recently, metal molding has become essential not only for automobile parts, but also mass production, and has greatly influenced production costs as well as the quality of products. Its surface has been treated by carburizing, nitriding and induction hardening, but these existing treatments cause considerable deformation and increase the expense of postprocessing after treatment; furthermore, these treatments cannot be easily applied to parts that requiring the hardening of only a certain section. This is because the treatment cannot heat the material homogeneously, nor can it heat all of it. Laser surface treatment was developed to overcome these disadvantages, and, when the laser beam is irradiated on the surface and laser speed is appropriate, the laser focal position is rapidly heated and the thermal energy of surface penetrates the material after irradiation, finally imbuing it with a new mechanical characteristic by the process of self-quenching. This research estimates the material characteristic after efficient and functional surface treatment using HPDL, which is more efficient than the existing CW Nd:YAG laser heat source.

The effects of low-level laser therapy in patients with wrist pain: is this Mickey Mouse science?

  • Petrofsky, Jerrold S.;Chung, Wendy;De Fazio, Lesley;Harris, Holly;Laymon, Michael;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Objective: Low level laser treatment (LLLT) is widely used in physical therapy practice. It is combined with physical therapy or LLLT alone. The purpose of this study is to evaluate the effectiveness of LLLT on patients' perception of general wrist pain. Design: Longitudinal study. Methods: Forty-eight subjects with wrist pain who were in the age range of 18-70 years old were examined. The subjects were asked, via an interview and a visual analog scale, to grade their wrist pain. They were asked to rotate their wrists through full range of motion and the angle at which any pain occurred was assessed. Each subject was then exposed to one of the following: 1) treatment with an infrared laser with the power turned off (placebo), 2) treatment with an infrared therapeutic laser, 3) treatment with a red therapeutic laser, 4) treatment with an ultraviolet laser, 5) treatment with a blue laser, 6) treatment with a Mickey Mouse flashlight. The duration of the treatment was 3 sessions in 3 days. Results: The results of the experiments showed that while pain was reduced both immediately after and the next day after laser therapy (p<0.05), there was no significant difference between the laser groups and the placebo group. However, the Mickey Mouse flashlight treatment groups had a greater range of motion than the laser groups (p<0.05). Conclusions: While pain was reduced in all laser groups, it was probably a placebo effect. The Mickey Mouse flashlight group probably received benefit from the heat of the flashlight.

Usefulness of a 1,064 nm Microlens Array-type, Picosecond-dominant Laser for Pigmented Scars with Improvement of Vancouver Scar Scale

  • Ahn, Kwang Hyeon;Park, Eun Soo;Nam, Seung Min
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.19-23
    • /
    • 2019
  • Background and Objectives The picosecond 755 nm alexandrite laser was first approved by the US FDA in 2012. A previous study described the use of a 1,064 nm picosecond laser with a micro-lens array (MLA) in peri-areolar scarring from breast reconstruction surgery and reported significant improvement in the texture and aesthetic appearance of the scar without other wound complications. The purpose of this study was to evaluate the improvement of overall scarring, not just pigmentation, in the picosecond laser treatment of patients with pigmentations. Materials and Methods Sixteen patients who underwent 1,064 nm picosecond laser treatment from June 2016 to December 2018 were enrolled in this study. Patients received two to six sessions of picosecond laser treatment at intervals of 4 weeks. Before and after the laser treatment, the patients evaluated their own satisfaction score and a physician evaluated the Vancouver Scar Scale. To evaluate the satisfaction score and complication rate, a retrospective chart review was done. Results Seven were female and nine were male. The mean of the patients' satisfaction score before the treatment was 1.44 (interquartile range [IQR], 1-2) and 3.00 (IQR 2.25-3.75) six months after treatment. The mean of the Vancouver Scar Scale before the treatment was 9.69 (IQR 8-11), and 6.25 (IQR 5-7.75) six months after treatment. All the results were statistically significant (p<0.01). Conclusion This study provides evidence that the use of a 1,064 nm picosecond laser treatment for pigmented scars can be effective in improving the pigmentation and overall scar status, including vascularity, height, and pliability, with the results of a decrease in the VSS scores between treatments.

Effective Low-Level Laser Therapy Including Laser Acupuncture Treatment Conditions for Non-Specific Chronic Low Back Pain: Systematic Review and Meta-Analysis

  • Yeum, Hyewon;Hong, Yejin;Nam, Dongwoo
    • Journal of Acupuncture Research
    • /
    • v.38 no.2
    • /
    • pp.85-95
    • /
    • 2021
  • Low-level laser therapy including laser acupuncture has been widely used for non-specific chronic low back pain in primary Korean medical clinics. However, there is no critically appraised data regarding which treatment conditions are most effective. A systematic review and meta-analysis was conducted to determine effective treatment conditions using 12 databases (PubMed, Ovid, CENTRAL, KoreaMed, KMBASE, KISS, NDSL, KISTI, OASIS, CNKI, CiNII, and J-STAGE). There were 1,019 studies retrieved and 13 studies included in this review. It was determined that when the power output was ≥ 50 mW, the beam size was increased to ≥ cm2, the energy dose was increased to ≥ 4 J per point, the treatment interval was increased to ≥ 3 times a week, and the number of treatment sessions was increased to ≥ 10 treatments, these conditions appeared to increased treatment effectiveness.