• Title/Summary/Keyword: Laser threshold

Search Result 309, Processing Time 0.029 seconds

Laser Welding Analysis for 3D Printed Thermoplastic and Poly-acetate Polymers (3차원 광경화성 수지와 폴리아세테이트 수지의 레이저 접합해석)

  • Choi, Hae Woon;Yoon, Sung Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.701-706
    • /
    • 2015
  • In this study, experimental and computer simulation results are compared and analyzed. Three-dimensional (3D) fabricated matrices from an MJM 3D printer were joined with poly-acetate thermoplastic polymers using a diode laser. A power range of 5-7 W was used to irradiate the boundary of two polymers. The heated polymers flowed into the matrices of the 3D fabricated structure, and reliable mechanical joining was achieved. Computer simulation showed the temperature distribution in the polymers, and flow direction was estimated based on the flux and temperature information. It was found that the more than the minimum energy threshold was required to effectively join the polymers and that two scans at low-speed were more effective than four scans at high speed.

Laser Photobiostimulation-Induced Hypoalgesia in Rats (쥐에 대한 레이저 자극시 진통효과)

  • Kwak, Hyun-Ho;Kim, Do-Hyung;Choi, Hyun-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.5 no.2
    • /
    • pp.15-22
    • /
    • 1998
  • Laser photobiostimulation (LPBS) is one of the recent additions to therapeutic procedures used in chronic pain management. Though widely used, a clear understanding of its mechanism of action was not disclosed. In addition, the energy density that produces maximal benefit has not yet been established. The purposes of this study were to determine the effects of LPBS on pain relief in rat and to determine treatment dosage. Eight, 8-week old female, Sprague-Dawley rats were employed. All subjects were assigned to one of four groups: a sham laser group, a 0.4 $J/cm^2$ laser group, a 2.0 $J/cm^2$ laser group, and a 6.0 $J/cm^2$ laser group. Ga-As laser (904 nm wavelength) of three different energy densities (0.4, 2.0, 6.0 $J/cm^2$) was applied on a tail acupuncture point and tail-flick latencies were measured five times pre-and post-treatment as following schedules: 30 minutes, 1 hour. 24 hours. 48 hours, and 7 days later. An increase in pain threshold was demonstrated following LPBS, employing rat tail-flick test. LPBS of 2.0 $J/cm^2$ produced hypoalgesia of rapid onset and short duration (1 hour, 24 hours) while the response to 6.0 $J/cm^2$ was delayed and lasted longer (48 hours, 7 days). LPBS of 0.4 $J/cm^2$ did not produce any hypoalgesia.

  • PDF

Color modification inside a transparent glass(BK7) using a femtosecond laser (펨토초 레이저 기반 투명유리(BK7) 내부의 컬러 미세형상 가공)

  • Kim, Hoon-Young;Yoon, Ji-Wook;Choi, Won-Seok;Park, Jung-Kyu;Choi, Ji-Yeon;Kim, Jae-Goo;Whang, Kyoung-Hyun;Cho, Sung-Hak
    • Laser Solutions
    • /
    • v.15 no.3
    • /
    • pp.16-19
    • /
    • 2012
  • We have successfully formed brown colored patterns inside of a transparent borosilicate glass generally known as BK7, laying the focus of near infrared Ti: sapphire femtosecond laser beam in the bulk BK7 glass. It is important to keep the laser power well below the damage threshold of BK7 in forming the color center. According to the low laser power, there was no laser induced mechanical damage such as cracks or threads in the color formed area. From the absorbance spectrum and its gaussian fitting, we found the band gap of BK7, 4.21eV, and three absorption edges.

  • PDF

THE RELIABILITY OF LASER DOPPLER FLOWMETER IN PULP VITALITY TEST OF TEETH (치수생활력 검사 방법으로서 laser Doppler flowmeter의 신뢰도)

  • Nam, Dong-Woo;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.683-690
    • /
    • 1998
  • The purpose of this study was to evaluate the reliablity of laser Doppler flowmeter on the permanent maxillary central incisors with open apex. Laser Doppler flowmeter and electric pulp tests were done in 35 elementary students aged between 8 and 9 years and 35 females and males aged between 23 and 24 years. Teeth with open apex were confined to root developmental stage 5 and 6 by Moorrees classification. The threshold of electric pulp tests was decided the time of tingling sensation. More than three different electric pulp tests applied on every teeth with more than 3 minutes interval between each teeth due to the false response. Laser Doppler flowmeter test stablilzation and observation stages took more than 5 minutes each LDF values and electric pulp test thresholds were analyzed with student t-test. The results were as follows: 1. The electric pulp test threshold on teeth with immature and mature roots showed 28.4% and 100% response respectively, and the the LDF values on teeth with immature and mature roots showed 100% response. 2. The EPT thresholds on teeth with immature roots were larger than thresholds on teeth with mature roots(p<0.01). 3. No significant differences were found in the LDF values on teeth with immature and mature roots.

  • PDF

Comparisons of lasing characteristics of InGaAs quantum-dot and quantum well laser diodes (InGaAs 양자점 레이저 다이오드와 양자우물 레이저 다이오드의 특성 비교)

  • Jung, Kyung-Wuk;Kim, Kwang-Woong;Ryu, Sung-Pil;Cho, Nam-Ki;Park, Sung-Jun;Song, Jin-Dong;Choi, Won-Jun;Lee, Jung-Il;Yang, Hae-Suk
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.371-376
    • /
    • 2007
  • We have investigated the lasing characteristics of the InGaAs quantum dot laser diode (QD-LD) and InGaAs quantum well laser diode (QW-LD) operated at the 980 nm wavelength range. The 980-nm lasers are used as a pumping source for a erbium-doped fiber amplifier (EDFA) and it shows high efficiency in long-haul optical fiber network. We have compared the threshold current density, the characteristic temperature, the optical power and the internal efficiency of QD-LD and QW-LD under a pulsed current condition. The QD-LD shows superior performances to the QW-LD. Further optimization of a LD structure is expected to the superior performances of a QD-LD.

Fabrication and performance analysis of cost-effective fiber grating lasers for WDM-PON systems (WDM-PON 시스템용 저가형 Fiber Grating Laser의 제작 및 성능 분석)

  • Cho, Seung-Hyun;Lee, Woo-Ram;Lee, Jie-Hyun;Park, Jae-Dong;Kim, Byoung-Whi;Kang, Min-Ho;Shin, Dong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.13-20
    • /
    • 2005
  • Fiber-Bragg-grating external cavity laser(FGL) modules were fabricated and experimentally analyzed. Proposed as a cost-effective solution for optical sources in the WDM-PON access network, FGL modules were packaged to TO-CAN type. We obtained a low threshold current of 13 mA, and an optical output power of 3.6 mW with a bias current of 60 mA at $25^{\circ}C$. The lasing wavelength dependencies on current and temperature were as small as 5.2 pm/mA and 30 pm/$^{\circ}C$, respectively. These change rates of the wavelength with the temperature and current are smaller than those of the DFB laser. Single-mode oscillations with the side-mode suppression ratio(SMSR) over 30 dB are maintained above the threshold current level. The FGL modules can be directly modulated at 155 Mbps, PRBS(2$^{23}$ -1) NRZ signal. Through the BER plots, we did not see the significant degradations before and after the transmission over 20km of the SMF at 155 Mb/s.

Analysis of Leakage Current of a Laser Diode by Equivalent Circuit Model (등가회로 모델에 의한 레이저다이오드의 누설전류 해석)

  • Choi, Young-Kyu;Kim, Ki-Rae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.330-336
    • /
    • 2007
  • A single pixel photon counting type image sensor which is applicable for medical diagnosis with digitally obtained image and industrial purpose has tern designed with $0.18{\mu}m$ triple-well CMOS process. The designed single pixel for readout chip is able to be operated by single supply voltage to simplify digital X-ray image sensor module and a preamplifier which is consist of folded cascode CMOS operational amplifier has been designed to enlarge signal voltage(${\Delta}Vs$), the output voltage of preamplifier. And an externally tunable threshold voltage generator circuit which generates threshold voltage in the readout chip has been newly proposed against the conventional external threshold voltage supply. In addition, A dark current compensation circuit for reducing dark current noise from photo diode is proposed and 15bit LFSR(Linear Feedback Shift Resister) Counter which is able to have high counting frequency and small layout area is designed.

The in vivo photothermal treatment of gold nanorod in the mouse ear model

  • Liu, Bruce Yao Wen;Chen, Cheng-Lung;Lee, Shin-Yu;Chang, Fu-Hsiung;Lin, Win-Li;Chia, Chih-Ta;Chen, Yang-Yuan
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.41-50
    • /
    • 2014
  • Gold nanorod's exceptional light to heat transduction is a robust phonomenon that has been extensively verified. The phenomenon is a trait from which many novel applications across disciplines have been proposed. In this investigation, the feasibility of utilizing heat harvested from such photothermal method to combat cancer is presented. Using non-invasive laser methods, an in vivo study is conducted on mouse ear tumors administered with gold nanorods (Au NRs). An emphasis is placed on monitoring the tumor developments after photothermal treatments, over time. The findings reveal significant tumor growth surpression at a threshold laser power of $0.6W/cm^2$ lasting 2 minutes; this energy also brought about dramatic size reduction in treated tumors. Furthermore, the apparent formation of an eschar over the laser treated region indicates extensive hemorrhagic necrosis of the tumor tissue; a phenomenon implicative to the inhibition of angiogenesis.

Development of a Measurement System for Axial-symmetric Objects Using Vision Sensor (시각센서를 이용한 축대칭 물체 측정 시스템 개발)

  • Lee, S.R.;Kim, C.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.34-41
    • /
    • 1997
  • The dimension measurement problem of products has been a major concern in the quality control in the industrial fields. A non-contacting measurement system using the vision sensor is proposed in this paper. The system consists of a CCD camera for the image capture, a frame grabber for the acquired image processing, a laser unit for the illumination, scanning unit for the measurement, and a personal computer for the geometry computation. The slit beam which is generated by passing the laser beam through a cylin- drical lens is fired to the axial-symmetric object on the rotating plate. The image of objects reflected by the laser slit beam, acquired by the CCD camera, becomes much brighter than the other parts of objects. After the histogram of brightness for the captured image is calculated, low intensity pixels are filtered out by threshold method. The performance of proposed measurement system is obtained for several different axial symmetric objects. The proposed system is verified as a good tool for measuring axial-symmetric parts in a limited condition with a minor investment cost.

  • PDF

Excitation Wavelength Dependence of Laser Ablation Mechanism of Urethane-Urea Copolymer Film Studied by Time-Resolved Absorbance Measurements

  • Tada, Takuji;Asahi, Tsuyoshi;Masuhara, Hiroshi;Tsuchimori, Masaaki;Watanabe, Osamu
    • Journal of Photoscience
    • /
    • v.10 no.1
    • /
    • pp.97-104
    • /
    • 2003
  • The excitation wavelength dependence of laser ablation dynamics of an azobenzene-containing urethane-urea copolymer film was investigated by measuring the laser fluence dependence of etch depth, transient absorbance change at each excitation wavelength, and transient absorption spectra. Moreover expansion/contraction dynamics was studied by applying nanosecond time-resolved interferometry. The threshold was determined at several excitation wavelengths from etch depth measurement, while time-integrated absorbance was obtained under excitation conditions. The photon energy required to remove the topmost of surface layer of the film did not .depend on excitation wavelength, and the penetration depth of excitation pulse dominated the etch depth. When the excitation wavelength was longer than 500 nm, permanent swelling was clearly observed but not for shorter wavelength excitation. In the latter case, photoisomerization occurred during excitation and the following photoreduction may play an important role. On the basis of the observations made in this study, a photochemical and photothermal mechanisms can explain mostly the short and long wavelength excitation results, respectively.

  • PDF