• Title/Summary/Keyword: Laser surface texture

Search Result 43, Processing Time 0.021 seconds

Simulation of laser zone texturing of Ni-P disk substrates by PLIC method (PLIC 방법을 사용한 Ni-P 디스크의 레이저 존 텍스처링 모사)

  • Kim, Heon-Joon;Ha, Eung-Ji;Kim, Woo-Seung
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.255-260
    • /
    • 2000
  • Laser zone texture technology is widely used to enhance the tribological performance of high areal density media. This work investigates the transient process of melting and microscale surface deformation upon pulsed laser heating of Ni-P hard disk substrates by PLIC(Piecewise Linear Interface Calculation) method. The present results are compared with both the experimental and the Donor-Acceptor method results. It is found that the results from PLIC method are better than those of Donor-Acceptor method and they are in good agreements with the experimental results.

  • PDF

The Effects of the Argon Laser Irradiation on the Root Surface : A Scanning Electronic Microscopic Study (아르곤 레이저 조사시 치근면 변화에 관한 주사 전자 현미경적 연구)

  • Eun, Hee-Jong;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.861-872
    • /
    • 1999
  • Since pathologic changes of exposed root surface inhibit cell attachment and new attachment of connective tissue have been made, many efforts were apply to change the exposed root surface condition. Scaling and root planing can not remove the endotoxin completely and forms the smear layer which prohibits the new attachment of connective tissue. Therefore, many kinds of chemicals were used for controlling the pathologic change of the root surface. The purposes of this study was to compare and observe the changes of the exposed root surface treated by scaling and root planning, Tetracycline HCl and Argon Laser. After the scaling and root planning of ten extracted premolars, the differences & the root surface among groups were observed under SEM. Control group showed smear layer and irregular amorphous surface. The dentinal tubule was not exposed. The debris and scale like texture were also observed. Tetracycline HCl treated group showed relatively smooth surface and the collagen fiber was observed in the dentinal tubule. Argon Laser treated group showed the most effective results under the conditions of 0.8 to 1.0w irradiation for 0.5 to 1.0 sec with pulse wave. The results of this study showed that the root surface change was associated with the intensity and the duration of Argon Laser irradiation. Further investigation for the surface change with the Argon Laser irradiation is recommended for understanding of clinical effect.

  • PDF

Effect of Nd:YAG laser irradiation on adherence of retrograde filling materials: evaluation by micro-computed tomography

  • Kim, Minyoung;Kim, Hyeon-cheol;Kwak, Sang Won;Yoon, Tai Cheol;Kim, Euiseong
    • The Journal of the Korean dental association
    • /
    • v.54 no.11
    • /
    • pp.865-873
    • /
    • 2016
  • Background/Purpose: The purpose of this study was to evaluate the effect of Nd:YAG irradiation on adherence of retrograde filling materials (mineral trioxide aggregate [MTA] and Super-EBA) by micro-computed tomography (CT) measurement and to observe the dentinal surface after irradiation by scanning electron microscopy (SEM). Materials and methods: Forty retrofilling models using extracted human teeth were divided into four groups according to the material and method used: ProRoot MTA (MTA group), Super-EBA (EBA group), MTA with Nd:YAG laser irradiation (LMTA group), and Super-EBA with Nd:YAG laser irradiation (LEBA group). All specimens were stored in 100% humidity for 24 hours until micro-CT was performed. The gap volume of the tooth/material interface was measured using the CTAn program. In six samples, the laser-irradiated dentin surface was observed using SEM. Results: The mean percent difference in gap volume was not statistically significant between the Nd:YAG laser-irradiated groups and non-irradiated in both materials(P > 0.05). The gap volume in the MTA group was significantly lower than that in the EBA group (P < 0.05). Examination of the non-irradiated specimens by SEM showed patent dentinal tubules. In contrast, alterations in the texture of the dentin surface and obliteration of the dentinal tubules were evident in the Nd:YAG laser-irradiated specimens. Conclusion: In this study, changes in the dentinal surface after Nd:YAG irradiation did not affect adherence between the apical filling material and the dentin wall.

  • PDF

Features and Properties of $YBa_2$$Cu_3$$O_{7-x}$ Films Grown on SrTi$O_3$ by High Frequency PLD

  • Shi, D.Q.;Ko, R.K.;Song, K.J.;Chung, J.K.;Choi, S.J.;Park, Y.M.;Shin, K.C.;Yoo, S.I.;Park, C.
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.75-79
    • /
    • 2003
  • YBCO films were deposited with various thicknesses from 100nm to 1.6$\mu\textrm{m}$ on single crystal $SrTiO_3$ substrates by pulsed laser deposition (PLD). The effects of different deposition conditions, especially different deposition rates by means of changing the pulsed laser frequency up to 200Hz, on the J$_{c}$ value were studied. For YBCO film with the thickness of 200nm, the $J_{c}$ value of $2.1MA/\textrm{cm}^2$ has been achieved under the high deposition rate of 3.2nm/s (190nm/min). The $J_{c}$ can be maintained greater than $1M/\textrm{cm}^2$ with the thickness less than 1$\mu\textrm{m}$. The X-ray analysis was used to examine the texture, crystallization and surface quality. The SEM was employed to analyze the surface of YBCO, and it was shown the surface of YBCO film became rougher with increasing the thickness. There were many large singular outgrowths and networks of outgrowths on the surface of YBCO films which lowered the density of thick YBCO film. The outgrowth network was probably the a-axis YBCO corresponding to XRD $\theta$-2$\theta$scan and $\chi$-scan which were used to characterize a-axis orientation of YBCO film. The reason for J$_{c}$ declining with increasing the thickness was studied and discussed.sed.

  • PDF

The design of 4S-Van for implementation of ground-laser mapping system (지상 레이져 매핑시스템 구현을 위한 4S-Van 시스템 설계)

  • 김성백;이승용;김민수
    • Spatial Information Research
    • /
    • v.10 no.3
    • /
    • pp.407-419
    • /
    • 2002
  • In this study, the design of 4S-Van system is discussed fur the implementation of laser mapping system. Laser device is fast and accurate sensor that acquires 3D road and surface data. The orientation laser sensor is determined by loosely coupled (D)GPS/INS Integration. Considering current system architecture, (D)GPS/INS integration is performed far performance analysis of direct georeferencing and self-calibration is performed for interior and exterior orientation and displacement. We utilized 3 laser sensors for compensation and performance improvement. 3D surface data from laser scanner and texture image from CCD camera can be used to implement 3D visualization.

  • PDF

The Effects of Nd:YAG Laser Irradiation on the Root Surface;A Scanning Electron Microscopic Study (Nd:YAG 레이저 조사시 치근면에 미치는 효과에 관한 주사전자현미경적 연구)

  • Lee, Su-Jeong;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.495-514
    • /
    • 1997
  • The purpose of this study was to evaluate the in vitro effects of Nd:YAG laser irradiation on removal of a root surface smear layer after root planing in comparison with Tetracycline HCl. The 60 extracted human teeth due to severe periodontal disease were vigorously scaled and root planed with Gracey curet. Thirty specimen($5{\times}5{\times}2mm$) were obtained from root planed surface of 30 human teeth and assigned randomly to one of three groups : root planed group(5 specimen), Tetracycline HCI group(5 specimen, burnished for 5 minutes), and Nd:YAG laser group(25 specimen, German Dental Laser, Fotona Twinlight). Nd:YAG laser group was divided into 4 subgroups according to power of 1W, 1.5W, 2W, 3W at frequency to 10Hz. The specimen were then fixed, and examed by Scanning electron microscopic study. 30 of 60 human teeth used to measurement of the intrapulpal temperature rise during laser irradiation. Laser-irradiated surface exhibited various surface texture from relative flat surface to irregular surface with patent dentinal tubules of various shape and size. In some area, the root surface alteration which are carbonization, pit and crater formation and melting and resolidification were observed. The number of exposed dentinal tubules per unit($100_{\mu}m^2$) on tetracycline HCI group was more than that in the laser group below 1.5W of power(150mJ/pulse) and was significantly less than that in laser group above 2W of power(200mJ/pulse)(P<0.OOl). As power increased the intrapulpal temperature rise also increased. The result suggested that the parameter which effectively remove root surface smear layer than tetracycline HCI may cause thermal damage to pulp and root surface alteration result from laser exposure would indicate need for additional instrumentation. Thus, Nd:YAG laser irradiation in these parameter may not be appropriate for clinical use as adjunct to conventional periodontal therapy.

  • PDF

Nano-tribology of laser textured hard disk by contact start/stop test (CSS test에 의한 레이저 텍스쳐 디스크의 나노-트라이볼로지)

  • Kim, Woo-Seok;Hwang, Pyung;Kim, Jang-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1589-1595
    • /
    • 2000
  • 레이저 텍스쳐와 미케니칼 텍스쳐 컴퓨터 하드디스크의 마찰과 마코 매카니즘이 Contact Start/Stop test 실행후의 특성들에 대해 연구되었다. 다양한 분석적이고 기계적인 테스트 기술들이 이용되었다. 형상, 조도, 화학적 조성, 기계적 성질, CSS 로부터 기인된 코팅의 마찰특성들에 대해 그 변화들을 조사하였다. 즉, AFM(Atomic Force Microscopy), Nano-Indentation, Nano-Scratch, TOF-SIMS(Time of Flight Secondary Ion Mass Spectroscopy), AES(Auger Electronic Spectroscopy)등이 이 연구에 적용되었다. 레이저 텍스쳐 범프의 표면조도와 미케니칼 텍스쳐 지역의 표면조도는 각각 대략적으로 4nm 와 7nm 감소되었다. 탄성계수와 경도값은 CSS test후에 증가하였고 가장 바깥쪽의 코팅층의 변형강화가 생겨났다. 자성층과 Ni-P 층 사이에 점착성의 문제가 확인되었다. TOF-SIMS 분석은 C 와 $C_2F_5$의 세기에 있어서 감소를 드러냈고 이것은 코팅 표면에 윤활제 요소의 마모를 확실시 할수 있는 결과로 나타났다.

  • PDF

Improvement of Conductive Micro-pattern Fabrication using a LIFT Process (레이저 직접묘화법을 이용한 미세패턴 전도성 향상에 관한 연구)

  • Lee, Bong-Gu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.475-480
    • /
    • 2017
  • In this paper, the conductivity of the fine pattern is improved in the insulating substrate by laser-induced forward transfer (LIFT) process. The high laser beam energy generated in conventional laser induced deposition processes induces problems such as low deposition density and oxidation of micro-patterns. These problems were improved by using a polymer coating layer for improved deposition accuracy and conductivity. Chromium and copper were used to deposit micro-patterns on silicon wafers. A multi-pulse laser beam was irradiated on a metal thin film to form a seed layer on an insulating substrate(SiO2) and electroless plating was applied on the seed layer to form a micro-pattern and structure. Irradiating the laser beam with multiple scanning method revealed that the energy of the laser beam improved the deposition density and the surface quality of the deposition layer and that the electric conductivity can be used as the microelectrode pattern. Measuring the resistivity after depositing the microelectrode by using the laser direct drawing method and electroless plating indicated that the resistivity of the microelectrode pattern was $6.4{\Omega}$, the resistance after plating was $2.6{\Omega}$, and the surface texture of the microelectrode pattern was uniformly deposited. Because the surface texture was uniform and densely deposited, the electrical conductivity was improved about three fold.

Experimental Investigation of Concave and Convex Micro-Textures for Improving Anti-Adhesion Property of Cutting Tool in Dry Finish Cutting

  • Kang, Zhengyang;Fu, Yonghong;Chen, Yun;Ji, Jinghu;Fu, Hao;Wang, Shulin;Li, Rui
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.583-591
    • /
    • 2018
  • Tool-chip adhesion impacts on cutting performance significantly, especially in finish cutting process. To promote cutting tools' anti-adhesion property, the concave micro-grooves texture (MGT) and convex volcano-like texture (VLT) were fabricated separately on lathe tools' rake faces by laser surface texturing (LST). Various orientations of MGT and different area densities (9% and 48%) and regions (partial and full) of VLT were considered in textured patterns designing. The following orthogonal cutting experiments, machining of aluminum alloy 5038, analyzed tools' performances including cutting force, cutting stability, chip shape, rake face adhesion and abrasion. It indicated that under dry finish cutting conditions, MGT contributed to cutting stability and low cutting forces, meanwhile friction and normal force reduced by around 15% and 10%, respectively with a weak correlation to the grooves' orientation. High density VLT tools, on the other hand, presented an obvious anti-adhesion property. A $5{\mu}m$ reduction of crater wear's depth can be observed on textured rake faces after long length cutting and textured rake faces presented half size of BUE regions comparing to the flat tool, however, once the texture morphologies were filled or worn, the anti-adhesion effect could be invalid. The bearing ratio curve was employed to analysis tool-chip contact and durability of textured surfaces contributing to a better understanding of anti-adhesion and enhanced durability of the textured tools.

The Scanning Electron Microscopic study on the effect during subgingival calculus removal using Nd:YAG laser (치은연하치석제거술시 Nd : YAG 레이저를 이용한 효과에 관한 주사전자현미경적 연구)

  • Jeon, Yong-Seon;Choi, Byung-Son;Lee, Seok-Cho;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.411-424
    • /
    • 1997
  • The purpose of this study was to evaluate in vitro the effects during subgingival calculus removal using Nd:YAG laser. The study group was consisted of 30 teeth with advanced periodontal disease extracted before the start of periodontal therapy. The specimens were divided into 8 different groups : 1) untreated control 2) scaling and root planing only 3) laser treated using 150mJ/pulse, 1sec, 5sec, contact mode 4) laser treated using 200mJ/pulse, 5sec, contact mode 5) laser treated using 150mJ/pulse, 1sec, non-contact mode 6) laser treated using 200mJ/pulse, 5sec, non-contact mode 7) laser treated using l5OmJ/pulse, 1sec, contact mode with water irrigation 8) laser treated using 200mJ/pulse, 5sec, contact mode with water irrigation. All specimens were prepared for evaluation by scanning electron microscopy(SEM). Specimens from Group 2 exhibited a smear layer of scale like texture with parallel instrument tracks resulting from curet use. Specimens treated by contact mode, Group 3 and 4 featured surface changes not observed· in controls such as charring, randomly distributed pitting and crater formation, and melting down of the tooth material and calculus. Specimens treated by noncontact mode, Group 5 and 6 featured similar surface changes observed in contact mode. However, the differences between contact and non-contact groups not significant. Specimens treated by contact mode with water irrigation, Group 7 and 8 featured slight surface change compared to other groups. The results suggested that Nd: YAG laser did not completely remove the subgingival calculus but was possible the application as adjunctive method.

  • PDF