• Title/Summary/Keyword: Laser Vibration Measurement

Search Result 130, Processing Time 0.024 seconds

Three-dimensional vibration measurement algorithm using one laser scanning vibrometer (한대의 LSV 를 이용한 3 차원 진동측정방법)

  • Kim, Dong-Kyu;Song, Ha-Jun;Park, Kyi-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.935-939
    • /
    • 2012
  • 3D vibration measurement is achieved using one laser scanning vibrometer(LSV) and Laser scanner(LS) by moving the LSV to three arbitrarily locations from the principle that vibration analysis based on the frequency domain is independent of the vibration signal based on time domain. The proposed system has the same effect as using three sets of LSVs. It has an advantage of reducing equipment costs. Analytical approach of obtaining in-plane and out-of-plane vibration of surface is introduced using geometrical relations between three LSV coordinates and vibration measured at three different locations.

  • PDF

Vibration Measurements of Large-Scale Structure Using Laser and High-Speed CCD Camera (레이저와 고속 CCD 카메라를 이용한 대형구조물의 진동계측)

  • 이창복;안세호;양성훈;염정원;강동욱;김기두
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1104-1112
    • /
    • 2004
  • In this paper, we establish measurement methods of vibration frequency for three-dimensional behavior measurement of large-scale structure using laser and high-speed CCD camera. We project the diode laser having a smaller fluctuation on the object plane attached to the structure and measure the displacement of the structure using a precise relative measurement algorithm. When we use high-speed(120 frames/sec) CCD camera, we can measure the vibration frequency having the uncertainty within 0.5% by taking FFT on the displacement, from 0Hz to 40Hz. And we also confirm the reliability and economical string of the suggested measurement method of vibration frequency of the structure by showing the accuracy of displacement measurement using laser is comparable to that of relative positioning methods using GPS.

A study on the measurement of vibration using Laser Doppler Interferometer (레이저 도플러 간섭계를 이용한 진동 측정에 관한연구)

  • Kim, Chang-Hyun;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1738-1740
    • /
    • 1996
  • Laser Doppler Vibrometer using heterodyne method with a 632.8 nm He-Ne laser, has been developed for the measurement of small displacement and velocity. The measurement uses heterodyne method can be made insensitive to undesired vibration effect acting the system and can yield the sign of Doppler shift at the expense of increased complexity. A Bragg cell gives a frequency shift of 40MHz for heterodyne method. Frequency Modulated output is detected by spectrum analyzer.

  • PDF

Measurement of Vibration of Rotating Disk Cam Using He-Ne Laser and Photodiode (광소자와 헬륨-네온 레이저를 이용한 디스크 캠의 진동 측정)

  • Yoo, W.J.;Lee, G.S.;Kim, J.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.69-77
    • /
    • 1995
  • This laser measurement system has been developed using He-Ne laser and photodiode. The laser beam intensity transmitted on a photodiode was disturbed by eccentrically rotating disk cam with various speeds. The photodiode and an amplifier were used to change the detected beam intensity into voltage. The digitized data through the developed system were recorded on a micro-computer by using a signal analysis program. Its reliability was ascertained by using FFT analyzer. The vibration of rotating disk cam can be analyzed by measureing the intensity change of laser beam which the results by FFT analyzer were similar to. The amplifier was devised to be able to modulate the fluctuations of laser beam. The voltage could be linearly recorded with the change of the laser beam intensity.

  • PDF

The Measurement Systme of Vibration using Laser (레이져를 이용한 진동측정장치)

  • 진동희;전병철;조종두;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.357-362
    • /
    • 1993
  • In this study low priced laser measurement system was made, so its reliability was investigated Intensity distribution of laser beam measured by devised system and FFT analyzer and their results were examined for proving reliability of devised system. Transmitted laser beam intensity on photodiode changed by eccentrically rotating of disk cam and motor speed. To get results, photodiode and devised amplifier were used for changing voltage. After that, response signal was calculated by signal analysis program. It was found that the vibration of disk cam could be measured by the intensity distribution of laser beam and the same tendency was obtained by FFT. Change of motor speed effected the distribution of laser beam,which was obtained by devised system. Also linear distribution was got by sensitive balancing switch on amplifier according to the transmission of laser beam on photodide.

  • PDF

Papers : Simultaneous Measurement of Strain , Temperature , and Vibration Using Fiber Optic Sensor (논문 : 광섬유 센서를 이용한 변형률, 온도, 진동의 동시 측정)

  • Gang,Hyeon-Gyu;Bang,Hyeong-Jun;Hong,Chang-Seon;Kim,Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.44-48
    • /
    • 2002
  • In this paper, we demonstrated the simultaneous measurment of triple parameters such as strain, temperature, and vibration using single FBG/EFPI hybrid sensor. The FBG/EFPI sensor system for the strain and temperature measurement and the EFPI sensor system for the the vibration measurement were combined by a wavelength division multiplexer. The optical source of FBG/ EFPI sensor system is a wavelength-swept fiber laser(WSFL) and that of an EFPI sensor system is a laser diode. We performed the simultaneous measurement of thermal strain, temperature, and vibration of a aluminum beam placed in a thermal chamber and validated the efficiency of the constructed measurment system.

A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis (모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기)

  • 라종필;최지은;박기환;경용수;왕세명;김경석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.274-280
    • /
    • 2002
  • This paper addresses the vibration mode shape measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series form, the analysis of the vibration mode shape techniques for straight Bine scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a plate

  • PDF

Performance of Different Sensors for Monitoring of the Vibration Generated during Thermosonic Non-destructive Testing

  • Kang, Bu-Byoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Vibration monitoring is required for reliable thermosonic testing to decide whether sufficient vibration is achieved in each test for the detection of cracks. From a practical point of view, a cheaper and convenient monitoring method is better for the application to real tests. Therefore, the performance of different sensors for vibration monitoring was investigated and compared in this study to find a convenient and acceptable measurement method for thermosonics. Velocity measured by a laser vibrometer and strain provide an equivalent HI when measured at the same position. The microphone can provide a cheaper vibration monitoring device than the laser and the heating index calculated by a microphone signal shows similar characteristics to that calculated from velocity measured by the laser vibrometer. The microphone frequency response shows that it underestimates high frequency components but it is applicable to practical tests because it gives a conservative value of HI.

MEASUREMENT OF THE VIBRATION MODE SHAPE USING THE TIME AVERAGE FSPI (시간평균 ESPI에 의한 진동 MODE SHAPE의 계측)

  • 최장섭;강영준;문상섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.308-313
    • /
    • 1995
  • Non-destructive inspection techniques using laser have been broading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics and computer. The remarkable inspection technique using laser speckle, so-called ESPI is aleady on the stage of on-line testing with commercial products in other nations. Especially, this technique is expected to be applied to the nuclear industry. Because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringers fso that fringe shift algorthms can be used to determine vibration interferograms recorded by the ESPI system.

  • PDF