• Title/Summary/Keyword: Laser Therapy

Search Result 560, Processing Time 0.029 seconds

Effect of fractional ablative carbon dioxide laser with lidocaine spray on skin flap survival in rats

  • Choi, Manki;Park, Youngsoo;Kim, Yong-Ha;Chung, Kyu Jin
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.4
    • /
    • pp.239-245
    • /
    • 2019
  • Background: Lidocaine spray is a local anesthetic that improves random-pattern skin flap survival. The fractional ablative carbon dioxide laser (FxCL) produces vertical microchannels that delivers topically applied drugs to the skin. In this study, we hypothesized that FxCL therapy would enhance the lidocaine effect to improve random-pattern skin flap survival in rats. Methods: McFarlane random-pattern skin flaps were elevated in 48 rats, which were divided into four groups according to treatment: FxCL+lidocaine, FxCL, lidocaine, and nontreatment (control). On postoperative day 7, necrotic flap areas, the number of capillary vessels, and neutrophil count were evaluated. Anti-rat vascular endothelial growth factor (VEGF) and CD31 antibody activity were also evaluated by immunohistochemical staining. Results: Flap survival rate was $53.41%{\pm}5.43%$, $58.16%{\pm}4.80%$, $57.08%{\pm}5.91%$, and $69.08%{\pm}3.20%$ in the control, lidocaine, FxCL, and FxCL+lidocaine groups, respectively. Mean neutrophil count in the intermediate zone excluding the necrotic tissue was $41.70{\pm}8.40$, $35.43{\pm}6.41$, $37.23{\pm}7.15$, and $27.20{\pm}4.24cells/field$ in the control, lidocaine, FxCL, and FxCL+lidocaine groups, respectively. Anti-rat VEGF and CD31 antibody activity were the highest in the FxCL+lidocaine group. Conclusion: FxCL with lidocaine had a positive effect on random-pattern skin flap survival in rats. Thus, FxCL with lidocaine spray should be considered as a new treatment option to improve flap viability.

Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia

  • Safi, Ihab Nabeel;Hussein, Basima Mohammed Ali;Al-Shammari, Ahmed Majeed
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.242-257
    • /
    • 2022
  • Purpose: This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods: Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 or 90 days). Each subgroup (20 implants) was subdivided into 4 groups (without cells, PDLSC sheets, BMMSC sheets, and co-culture cell sheets). All groups underwent histological testing involving haematoxylin and eosin staining and immunohistochemistry, stereoscopic analysis to measure the PDL width, and field emission scanning electron microscopy (FESEM). The natural lower central incisors were used as controls. Results: The BMMSCs co-cultured with PDLSCs generated a well-formed PDL tissue that exhibited positive periostin expression. Histological analysis showed that the implantation of coated (Ti and zirconia) dental implants without a cell sheet resulted in a well-osseointegrated implant at both healing intervals, which was confirmed with FESEM analysis and negative periostin expression. The mesenchymal tissue structured from PDLSCs only or co-cultured (BMMSCs and PDLSCs) could form a natural periodontal tissue with no significant difference between Ti and zirconia implants, consequently forming a biohybrid dental implant. Green fluorescence for periostin was clearly detected around the biohybrid implants after 45 and 90 days. FESEM showed the invasion of PDL-like fibres perpendicular to the cementum of the bio-hybrid implants. Conclusions: β-TCP-coated (Ti and zirconia) implants generated periodontal tissue and formed biohybrid implants when mesenchymal-tissue-layered cell sheets were isolated from PDLSCs alone or co-cultured BMMSCs and PDLSCs.

A Case Report of Stevens-Johnson Syndrome with Intraoral Lesions (구강 증상을 동반한 Stevens-Johnson 증후군의 임상 증례)

  • Kim, K.A.;Jang, S.Y.;Ryu, S.S.;Byun, Y.H.;Lee, J.M.;Lee, C.H.;Kee, W.C.;Choi, J.K.
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.23-29
    • /
    • 1997
  • A 49 years old male patient was referred from the Department of Medicine, KNUH for the management of painful oral lesions. The patient had disability of food and drug intake due to multiple intraoral ulcers. Extraoral findings showed upper and lower lip swelling, crust formation on the lips. The lesions were diagnosed as Stevens-Johnson syndrome based on clinical and hematologic findings. The patient was treated with saline irrigation and pulsed Nd:YAG laser irradiation. After 5 daily treatment, the lesions decreased in size and severity, and the patient became more comfortable for food intake and speeching. It was suggested from the results of this clinical trial that a pulsed Nd:YAG laser therapy would be helpful for the symptoms associated with Stevens-Johnson syndrome.

  • PDF

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

Antimicrobial effect of infrared diode laser utilizing indocyanine green against Staphylococcus aureus biofilm on titanium surface (티타늄 표면에 형성한 Staphylococcus aureus 바이오필름에 대한 인도시아닌 그린을 활용한 광역학치료의 항미생물 효과)

  • Seung Gi Kim;Si-Young Lee;Jong-Bin Lee;Heung-Sik Um;Jae-Kwan Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.55-63
    • /
    • 2024
  • Purpose: This study aimed to assess the antimicrobial efficacy of an 810-nm infrared diode laser with indocyanine green (ICG) against Staphylococcus aureus on sandblasted, large grit, and acid-etched (SLA) titanium surfaces, comparing its effectiveness with alternative chemical decontamination modalities. Materials and Methods: Biofilms of S. aureus ATCC 25923 were cultured on SLA titanium disks for 48 hours. The biofilms were divided into five treatment groups: control, chlorhexidine gluconate (CHX), tetracycline (TC), ICG, and 810-nm infrared diode laser with ICG (ICG-PDT). After treatment, colony-forming units were quantified to assess surviving bacteria, and viability was confirmed through confocal laser-scanning microscope (CLSM) imaging. Results: All treated groups exhibited a statistically significant reduction in S. aureus (P < 0.05), with notable efficacy in the CHX, TC, and ICG-PDT groups (P < 0.01). While no statistical difference was observed between TC and CHX, the ICG-PDT group demonstrated superior bacterial reduction. CLSM images revealed a higher proportion of dead bacteria stained in red within the ICG-PDT groups. Conclusion: Within the limitations, ICG-PDT effectively reduced S. aureus biofilms on SLA titanium surfaces. Further investigations into alternative decontamination methods and the clinical impact of ICG-PDT on peri-implant diseases are warranted.

Muscle Stiffness and Elasticity Related to Physical Therapeutic Modalities (물리치료에 따른 근육의 경도와 탄성도 비교)

  • Kim, Sung-Hwan;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.319-328
    • /
    • 2007
  • The purpose of this study was to quantitatively assess treatment effect of physical therapy on experimentally-induced masseter muscle fatigue by two parameters of muscle stiffness and elasticity. Three physical therapeutic modalities inducing electroacupunture stimulation therapy(EAST), Microwave diathermy and low-level laser therapy(LLLT) were compared. 10 healthy volunteers with normal occlusion (mean age of $26.3{\pm}1.16$ years, M:F=1:1) were participated in this study. All subjects were asked to chew gum on the right side until they felt pain(more and VAS 5 (0 to 10)) and their masseter muscles were examined with a tactile sensor in order to evaluate changes of stiffness and elasticity according to gum chewing and three physical therapeutic modalities. Subjective discomfort or pain was self-estimated by VAS as well. Unilateral gum chewing increased stiffness and decreased elasticity only on the chewing side but VAS increased on the both sides(p<0.05). EAST or Microwave diathermy greatly decreased stiffness and VAS and increased elasticity(p<0.05) but LLLT did not exhibit significant difference. From the results of this study, it is concluded that both EAST and Microwave diathermy have favorable effect on stiffness and elasticity of muscles and pain relief while effect of LLLT is not reliable. In addition, experimental unilateral gum chewing compromises stiffness and elasticity of masseter muscles only the chewing side while subjective discomfort or pain can be felt on the both sides.

Preparation and Characterization of Reduced Graphene Oxide with Carboxyl Groups-Gold Nanorod Nanocomposite with Improved Photothermal Effect (향상된 광열 효과를 갖는 카르복실화된 환원 그래핀옥사이드-골드나노막대 나노복합체의 제조 및 특성 분석)

  • Lee, Seunghwa;Kim, So Yeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.312-319
    • /
    • 2021
  • Photothermal therapy is a treatment that necrotizes selectively the abnormal cells, in particular cancer cells, which are more vulnerable to heat than normal cells, using the heat generated when irradiating light. In this study, we synthesized a reduced graphene oxide with carboxyl groups (CRGO)-gold nanorod (AuNR) nanocomposite for photothermal treatment. Graphene oxide (GO) was selectively reduced and exfoliated at high temperature to synthesize CRGO, and the length of AuNR was adjusted according to the amount of AgNO3, to synthesize AuNR with a strong absorption peak at 880 nm, as an ideal photothermal agent. It was determined through FT-IR, thermogravimetric and fluorescence analyses that more carboxyl groups were conjugated with CRGO over RGO. In addition, CRGO exhibited excellent stability in aqueous solutions compared to RGO due to the presence of carboxylic acid. The CRGO-AuNR nanocomposites fabricated by electrostatic interaction have an average size of ~317 nm with a narrow size distribution. It was confirmed that under radiation with a near-infrared 880 nm laser which has an excellent tissue transmittance, the photothermal effect of CRGO-AuNR nanocomposites was greater than that of AuNR due to the synergistic effect of the two photothermal agents, CRGO and AuNR. Furthermore, the results of cancer cell toxicity by photothermal effect revealed that CRGO-AuNR nanocomposites showed superb cytotoxic properties. Therefore, the CRGO-AuNR nanocomposites are expected to be applied to the field of anticancer photothermal therapy based on their stable dispersibility and improved photothermal effect.

Recovery of Streptococcus Mutans Biofilm after Photodynamic Therapy with Erythrosine and LED Light Source (Erythrosine과 LED를 이용한 광역동 치료 후 Streptococcus mutans 바이오필름의 회복)

  • Yongwook, Shin;Howon, Park;Juhyun, Lee;Siyoung, Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.2
    • /
    • pp.149-157
    • /
    • 2022
  • The aim of this study was to evaluate the effects of erythrosine-mediated photodynamic therapy (PDT) on Streptococcus mutans biofilm recovery by counting its colony-forming units (CFUs) and via confocal laser scanning microscopy analysis at different time points following PDT. In PDT, photosensitizer was an erythrosine. S. mutans ATCC25175 biofilms were irradiated using an LED curing light. Chlorhexidine (CHX) was used as positive control. After each antimicrobial treatment, samples were cultured to allow biofilm recovery. Viability was measured by calculating the CFU counts after treatment and after every 3 hours for up to 24 hours. Immediately after treatment, the PDT and CHX groups showed equally significant decreases in S. mutans CFU counts compared to the negative control. After 12 hours of reculture, the PDT group showed no significant difference in the decrease in CFU count compared to the negative control, whereas the CHX group showed significantly lower CFU counts throughout the 24-hour period. Erythrosine-mediated PDT can effectively inhibit S. mutans biofilm formation. However, biofilm recovery occurred earlier in the CHX group after PDT. This study provides insights into the clinical effectiveness of PDT in preventing dental caries.

Review of Clinical Studies on Korean Medicine for Acne Scar (여드름 흉터의 한의학 치료에 대한 국내 임상 연구 동향)

  • Jea, Ha-Kyung;Hwang, Mi-Ri;Ahn, Jae-Hyun;Jung, Hyun-A
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.31 no.2
    • /
    • pp.86-103
    • /
    • 2018
  • Objectives : The purpose of this study is to analyze various Korean medical treatments on acne scar and to propose better methods on clinical studies and effective treatments. Methods : Key word 'Acne Scar', published year '2010-2018' were searched on three domestic database systems (RISS, KISS, NDSL). Results : Among 9 studies, 8 studies were case reports and 1 study was comparative study. The treatment used in 9 studies were acupuncture(Subcision, Microneedle Therapy System, laser), pharmacopuncture, external application, dermabrasion, high frequency therapy. 7 out of 9 studies used more than 2 different treatments. The most popular treatment method was 'subcision', followed by 'MTS'. The most popular methods of assessment was QGASC. All studies using assessment methods measuring the severity of acne scar reported improvement, though only 1 study was proved to be statistically different. 1 study reported the side effect, and other 4 studies reported flushing, itching, pain. Conclusions : This study shows the effectiveness of Korean medical treatment on acne scar. It will be expected to use this various treatments and study methods for treating acne scar with Korean medicine, and conducting further clinical studies with higher credibility and reproducibility.

Successful Management of Hepatic Lipidosis Accompanied by a Feline Skin Fragility Syndrome-like Lesion in a Cat (고양이 피부유약증 유사병변을 동반한 지방간에 이환된 한 마리 고양이의 성공적인 치료증례)

  • Park, Hyoung-Jin;Hong, Eun-Ji;Kwon, Hyo-Jung;Park, Seong-Jun;Park, Joo Min;Song, Kun-Ho;Seo, Kyoung-Won
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.449-453
    • /
    • 2015
  • A 7-year-old spayed female Somali-cross cat was admitted with a 4-week history of anorexia, vomiting, weight loss, and lethargy. The cat was diagnosed with hepatic lipidosis. With intensive care and nutritional support via a nasogastric feeding tube for 3 weeks, the clinical signs of hepatic lipidosis were improved. However, skin lesions were found in the left and right scapular regions during the treatment that were suspected to be due to feline skin fragility syndrome (FSFS). Intensive wound healing therapy with granulated sugar, laser therapy, and a surgical flap was conducted. Skin lesions improved uneventfully without other clinical signs or recurrence of any skin lesion for a year. To our knowledge, this is the first report of a good prognosis in a hepatic disorder and concurrent FSFS.