• Title/Summary/Keyword: Laser Therapy

Search Result 560, Processing Time 0.022 seconds

A Study of Classified Comparison between Intravascular Laser Irradiation Therapy(ILIT) and Extravascular Laser Irradiation Therapy(ELIT) on Hypercholesterolemia (침습, 비침습 혈관레이저에 의한 고콜레스테롤혈증의 치료 효과 환자 유형별 비교)

  • Kwon, Mi-Jung;Kim, Min-Kyu;Heo, Sung-Woong;Youn, Hyoun-Min;Kim, Won-Il;Kwon, Jung-Nam;Kim, Young-Kyun
    • Journal of Pharmacopuncture
    • /
    • v.9 no.2
    • /
    • pp.141-154
    • /
    • 2006
  • Objective : The purpose of this study was to compare and analyze the effect of ILIT and ELIT according to sex, age, disease on Hypercholesterolemia. Methods : The 73 patients who were irradiated to the Intravascular Laser and the 57 patients who were irradiated to the Extravascular Laser from 1999 to 2005 in Sam-se oriental medicine hospital were the study group. They were irradiated two or three times a week and checked total cholesterol before and after ten times of irradiation. The checked total cholesterol point, 150-199 were normal, 200-239 were borderline, over 240 were abnormal. They were classified into male and female(43 persons, 87 persons), adult and 01d(62 persons, 68 persons), cardiovascular disease and the other diseases(70 persons, 60 persons). Results : 1. Male, adult, and the other diseases groups were more effective in cholesterol reduction and in convertible change of each group than female, old, and cardiovascular disease groups, but only the convertible change of each group had statistic significance. 2. In male, old, and cardiovascular disease, ELIT was more effective than ILIT in cholesterol reduction and convertible change of each group, but this result didn't have statistic significance. 3. In female, ELIT was more effective than ILIT in cholesterol change but this result didn't have statistic significance. ILIT was more effective than ELIT in convertible change of each group and this result had statistic significance. 4. In adult and the other diseases, ILIT was more effective in cholesterol reduction, but this result didn't have statistic significance. ILIT was more effective than ELIT in convertible change of each group too and this result had statistic significance. Conclusion: It was thought to be undesirable to decide which is more effective treatment, but to be more desirable to choose one of ILIT or ELIT according to sex, age, disease than to decide it indiscriminately.

A Pilot Study of Skin Resurfacing Using the 2,790-nm Erbium:YSGG Laser System

  • Rhie, Jong Won;Shim, Jeong Su;Choi, Won Seok
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • Background The erbium:yttrium scandium gallium garnet (Er:YSGG) laser differs from other laser techniques by having a faster and higher cure rate. Since the Er:YSGG laser causes an appropriate proportion of ablation and coagulation, it has advantages over the conventional carbon dioxide ($CO_2$) laser and the erbium-doped yttrium aluminum garnet (Er:YAG) laser, including heating tendencies and explosive vaporization. This research was conducted to explore the effects and safety of the Er:YSGG laser. Methods Twenty patients participated in the pilot study of a resurfacing system using a 2,790-nm Er:YSGG laser. All patients received facial treatment by the 2,790-nm Er:YSGG laser system (Cutera) twice with a 4-week interval. Wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture were measured. Results Study subjects included 15 women and five men. Re-epithelization occurred in all subjects 3 to 4 days after treatment, and wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture within 6 months of treatment. Conclusions The 2,790-nm YSGG laser technique had fewer complications and was effective in the improvement of scars, pores, wrinkles, and skin tone and color with one or two treatments. We expect this method to be effective for people with acne scars, pore scars, deep wrinkles, and uneven skin texture and color.

Thermoelastic beam in modified couple stress thermoelasticity induced by laser pulse

  • Kumar, Rajneesh;Devi, Shaloo
    • Computers and Concrete
    • /
    • v.19 no.6
    • /
    • pp.701-710
    • /
    • 2017
  • In this study, the thermoelastic beam in modified couple stress theory due to laser source and heat flux is investigated. The beam are heated by a non-Guassian laser pulse and heat flux. The Euler Bernoulli beam theory and the Laplace transform technique are applied to solve the basic equations for coupled thermoelasticity. The simply-supported and isothermal boundary conditions are assumed for both ends of the beam. A general algorithm of the inverse Laplace transform is developed. The analytical results have been numerically analyzed with the help of MATLAB software. The numerically computed results for lateral deflection, thermal moment and axial stress due to laser source and heat flux have been presented graphically. Some comparisons have been shown in figures to estimate the effects of couple stress on the physical quantities. A particular case of interest is also derived. The study of laser-pulse find many applications in the field of biomedical, imaging processing, material processing and medicine with regard to diagnostics and therapy.

Laser Understandings and Prospects of its Applications in Medicine (레이저의 이해와 그 의학적 응용에 관한 고찰)

  • 김현수;김귀언;추성실
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.19-37
    • /
    • 1995
  • The use of lasers in medicine has opened up entirely new fields of therapy and diagnosis. The process in biotechnical applications of laser is basically different from traditional one in other technical field because of critical account to the human body. This paper surveys the principle of biomedical applications as well as possible future developments in laser medicine. In particular, the following subjects are extensively presented : 1) laser-tissue interaction, 2) therapeutic, and diagnostic technique, 3) laser op tical fiber for medicine, and 4) laser safety.

  • PDF

The Spectrum of Laser Instruments for Laser Acupuncture Application (레이저침 시술에 사용되는 레이저 기기의 적용 범위에 대한 고찰)

  • Hwang, Eui-Hyoung;Yang, Chang-Sop;Jang, In-Soo
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • Objectives : During the past three decades there has been a significant evolution of laser acupuncture application in the nature of the clinical approach and the research of traditional medicine and laser therapy field. However, there have been no standard and guideline of laser equipment can be applied as laser acupuncture. This study aims to investigate the condition of laser equipment required as a laser acupuncture method. Methods : First, we performed literature search using the Medline(from 1999 to Oct 2008) to confirm types and ranges of laser equipments that can be applied as laser acupuncture. In addition, we investigated the characters of acupoints such as sites and depths, and compared with penetrating depths of each laser. Results : A total of 37 articles for clinical studies using laser acupuncture were selected, and 41 lasers were used. GaAs laser was used three times, GaAlAs laser 14, InGaAlP 18, HeNe laser 4, and Argon laser and CO2 laser were used one time, respectively. From all 361 points of fourteen meridians, depths of 341 points(94.5%) were 1 cun(2.3-3.2cm) or less. The mean depth of all points was 0.48 cun(1.1-1.5cm). Hence, it appeared that the majority of therapeutic lasers satisfied with the condition. HeNe, InGaAlP, GaAlAs, GaAs lasers are recommended for laser acupuncture, however, it may plausible that other surgical lasers could be used as the laser acupuncture, because it have the biostimulation effect to some extent, too. Conclusions : It is suggested that to select appropriate laser type and give the adequate output power to reach the acupoints under the skin using laser acupuncture. Further evaluation and research for the condition of laser acupuncture are warranted.

  • PDF

Quality assurance for computed-tomography simulator : Report of the AAPM Radiation Therapy Committee Task Group No.66 (Report of the AAPM Radiation Therapy Committee의 Task Group No.66에 의한 전산화 단층촬영 모의치료기의 정도 관리)

  • Lee, Yun-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.41-43
    • /
    • 2005
  • Purpose : Wish to present degree management process that is efficient confirm radiation treatment exclusive use CT simulator's Q.A item that become Q.A and Differentiation of diagnosis area that present Report of the AAPM Task Group No.66 using Q.A tool that produce itself and secure safe and correct CT-simulation process and equip convenience. Method and material : Manufacture CT simulator's Q.A tool on source and confirm virtue between isocenter of wall laser system, patient table, CT scanner's imaging plane that present in Report of the AAPM Task Group No.66 by daily publication unit. Result : Confirmed measured value from Report of the AAPM Task Group No.66 to confirmation of presenting degree management item in wall laser's ${\pm}2mm$, table's ${\pm}2mm$, imaging plane's ${\pm}2mm$ tolerance extent. Conclusion : There is unconfirmed item from CT-simulation process for therapy to CT Q.A protocol of existent diagnosis area, premising suitable degree management of radiation treatment exclusive use CT-simulator equipment confirming presenting Q.A item in Report of the AAPM Task Group No.66 safe and correct CT-simulation process guarantee can

  • PDF

Effect of LEDs Light of 633 nm Wavelength in Skin of Organism (633 nm 파장의 LED 광원이 생체 피부에 미치는 영향)

  • Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.760-765
    • /
    • 2008
  • Low power laser therapy is internationally certified and is known to be effective in stimulating DNA in living organisms, increasing protein synthesis and activating cell division, smoothing blood circulation, promoting cell activation, cell regeneration and function. It also has anti-inflammatory, anti-edemic, anti-fibrous dysplastic and neuralogic hyperfunctional effects. This study was intended to verify the effect of LED irradiation therapy on wound healing in cell and animal tests by applying LED irradiator using a laser and laser diode, which was independently designed and developed to emit beams of similar wavelength to that of a laser. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity and reservation. In case of cell proliferation experiment, each experiment was performed to irradiation group and non-irradiation group for tissue cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590 nm transmittance of micro-plate reader. In the wound healing experiment, 1$cm^2$ wounds on the skin wound of SD-Rat(Sprague-Dawley Rat) were made. Light irradiation group and none light irradiation group divided, each group was irradiated one hour a day for 9 days. As a result, the cell increase of tissue cells was verified in irradiation group as compared to non-irradiation group. And, compared with none light irradiation group, the lower incidence of inflammation and faster recovery was shown in light irradiation group.

Validity and Reliability of the Knee Joint Proprioceptive Sensory Measurements using a Smartphone (스마트폰을 이용한 무릎관절 고유수용성 감각 측정의 타당도와 신뢰도 검증)

  • Kim, Myung-Chul;Kim, Nam-Jae;Lee, Min-Soo;Moon, So-Ra
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.15-23
    • /
    • 2015
  • PURPOSE: We aims to promote the development of proprioception measurement using smartphones, goniometers, and laser pointers as compared to the conventional use of electrogoniometer measurement. METHODS: Measurements using an electrogoniometer were previously proved to be reliabile and valid. Among E-university students, 20 who had no fracture, operation history, or inflammatory arthritis were examined. These subjects had not performed regular exercise in the past 3 months. Proprioception measurements were performed using four different measurement tools, three times per day, for test-retest analysis. RESULTS: No notable test-retest differences were noted for any of the measurement methods (P>0.05). With regard to the test-retest reliability for each measurement method, we observed that the readings from both the electrogoniometer and smartphone have high reliability (ICC>0.80), whereas the readings from the laser pointer have moderate reliability (ICC>0.60). When assessing the concurrent validity between electrogoniometers with individual measurements, we did not observe any notable difference between the smartphone and electrogoniometer (P>0.05) and these tools in fact showed high correlation (r>0.60, P<0.05) and a moderate reliability (ICC>0.60). Moreover, there was no notable difference in between electrogoniometers and laser pointers (P<0.05). CONCLUSION: CONCLUSION: The findings of this suggested that proprioception can be measured by using smart-phones, and proved that this method has sufficient credibility. Moreover, we noted that the concurrent validity with smartphones was high in comparison with the conventional electrogoniometer, which also indicates the validity and credibility. Based on these findings, we conclude that the measurement of proprioception by using a smartphone can be widely adopted.

Low-level Laser Therapy with Novel Array of Light Source and Individualized Program for Treatment of Androgenetic Alopecia: A 16-week, Randomized, Double-blind, Sham Device-controlled Study

  • Kim, Jee-Woo;Kwon, Yeo-Seon;Chang, Yoon-Young;Hong, Sung-Ho;Shin, Jung-Won;Na, Jung-Im;Huh, Chang-Hun
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Background and Objectives Low-level laser therapy (LLLT) is used widely to promote hair growth in androgenetic alopecia (AGA). This study examined the clinical efficacy and safety of a home-use LLLT device with a newly designed array of light sources and software optimized for individual types of AGA. Materials and Methods The study was a randomized, double-blind, sham device-controlled trial. Forty-eight subjects (39 men and nine women) were assigned randomly in a 2:1 ratio to use either the test device (LG Pra'L HGN1, LG electronics, Korea) or sham device. The subjects used the LLLT device three times a week for 16 weeks. Phototrichogram was used to measure the hair density and hair thickness at 0, 8, and 16-weeks. Adverse events were closely monitored. Results After 16 weeks of using the device, the test group showed a significant increase in hair density and hair thickness compared to the control. In the test group, the hair density increased 6.96 counts/cm2 at eight weeks and 13.67 counts/cm2 at 16 weeks from the baseline. The hair thickness increased 7.21 ㎛ at eight weeks and 11.80 ㎛ at 16 weeks compared to the baseline. Conclusion The home-use LLLT device with a novel array of light sources and an individualized program according to the types of hair loss appears to be an effective and safe treatment modality for both male and female AGA patients.

Review of Low Level Laser Therapy on The Growth of Epiphyseal Plate (성장판의 성장에 저단계 레이저가 미치는 영향에 대한 고찰)

  • Choi, Ji Won;Jang, In Soo;Jeong, Min Jeong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.29-38
    • /
    • 2015
  • Objectives We aimed to identify the effectiveness of photobiomodulation using low level laser therapy (LLLT), light emitting diode (LED) and others on the growth of the length of the growth plate by reviewing literatures. Methods We searched literatures using PubMed, Science Direct, CINAHL, Korea Traditional Knowledge Portal (KTKP), Oriental Medicine Advanced Searching Integrated System (OASIS), China Knowledge Resource Integrated Database (CNKI), Japan Science and Technology Information Aggregator, Electronic (J STAGE), and Japan National Institute of Informatics Scholarly and Academic Information Navigator (CiNii) using the keywords "Growth plate" "Epiphyseal growth" "Epiphyseal plate" and "Laser", "light emitting diode (LED)", "near-infrared light", and "photobiomodulation". Search range included only original article which provided English abstract were selected. The search strategy contained no language limitation. Results A total 556 studies were found. Then, 551 were excluded by scanning titles and abstracts and finally 5 articles were selected. Five articles were RCTs using rodents. Two of the 5 articles used InGaAlP Laser (630-685 nm), and the other 3 articles used GaAlAs Laser (780, 820, and 870 nm) to investigated the effects of LLLT on the growth of the length of the epiphyseal cartilage and the number of chondrocytes and thickness of each zone of the epiphyseal cartilage. Two articles concluded that LLLT had a beneficial effect on the longitudinal growth of the growth plate. In growth of the epiphyseal plate, there were no significant differences in others. Conclusions It is might that LLLT influenced on the growth of epiphyseal plate by positive affect. However, further rigorous RCTs are warranted.