• Title/Summary/Keyword: Laser Testing Method

Search Result 120, Processing Time 0.022 seconds

Propagation of Bulk Longitudinal Waves in Thin Films Using Laser Ultrasonics (레이저 초음파를 이용한 체적종파의 박막 내 전파특성 연구)

  • Kim, Yun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.266-272
    • /
    • 2016
  • This paper presents the investigation of the propagation behavior of bulk longitudinal waves generated by an ultrafast laser system in thin films. A train of femtosecond laser pulses was focused onto the surface of a 150-nm thick metallic (chromium or aluminum) film on a silicon substrate to excite elastic waves, and the change in thermoreflectance at the spot was monitored to detect the arrival of echoes from the film/substrate interface. The experimental results show that the film material characteristics such as the wave velocity and Young's modulus can be evaluated through curve-fitting in numerical solutions. The material properties of nanoscale thin films are difficult to measure using conventional techniques. Therefore, this research provides an effective method for the nondestructive characterization of nanomaterials.

A Femtosecond Laser Metrology on the Thermal Conductivity of a Nanoscale Superconductor Material (펨토초 레이저를 이용한 나노 스케일 초전도 재료의 열전도율 평가)

  • Kim, Yun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.314-320
    • /
    • 2015
  • The present study investigates the thermal characteristics of a nanoscale superconductor material. A thin-film of $YBa_2Cu_3O_7-x$ was deposited on a $SrTiO_3$ substrate by using a pulsed-laser deposition technique and characterized using an ultrafast laser system. In order to extract a thermal conductivity value, a numerical solution for a transient one-dimensional heat conduction equation was obtained using a finite-difference method. The curve-fit shows a value 1.2 W/mK, which is relatively lower than those of bulk materials. This research provides a material property of superconductor thin-film required for the thermal design of micro or nanodevices.

A Study of Measurement of In-plane Displacement by CW Laser Speckle Photography and Image Processing (연속파 레이저 스페클 사진법(寫眞法)과 화상처리(畵像處理)에 의한 면내섭위(面內燮位) 측정(測定)에 관한 연구(硏究))

  • Kim, K.S.;Na, G.D.;Kim, T.H.;Chung, N.K.;Kim, C.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.47-55
    • /
    • 1990
  • This paper presents experimental results which explore the capability of a CW laser speckle photography for tile measurement of in-plane displacement at high temperature. The serious restrictions on the application of the method seem to be the ambient air turbulence and the change of surface texture caused by the oxidation, as they tend to decorrelate the double exposured speckle patterns. In order to assess only the effect of air turbulence, a ceramics-coated stainless steel plate is heated in air and Ar-laser specklegrams are made with combination of temperature and lateral translation displacement. The slight reduction in visibility of Young's fringes is observed at $1000^{\circ}C$. The analyses of Young's fringes are carried out by a image processing system using a TV-camera and computers, and the result agrees well with the micrometer reading. Futhermore, uncoated stainless steel and Hastelloy X plates are tested and the effect of oxidation is also evaluated. The experimental results demonstrate that a CW laser speckle photography is applicable at temperatures up to $1000^{\circ}C$.

  • PDF

Preliminary Study of the Measurement of Foreign Material in Galvanic Corrosion Using Laser Ultrasonic

  • Hong, Kyung Min;Kang, Young June;Park, Nak Kyu;Choi, In Young
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.323-327
    • /
    • 2013
  • A laser ultrasonic inspection system has the advantage of nondestructive testing. It is a non-contact mode using a laser interferometer to measure the vertical displacement of the surface of a material caused by the propagation of ultrasonic signals with the remote ultrasonic generated by laser. After raising the ultrasonic signal with a broadband frequency range using a pulsed laser beam, the laser beam is focused to a small point to measure the ultrasonic signal because it provides an excellent measurement resolution. In this paper, foreign materials are measured by a non-destructive and non-contact method using the laser ultrasonic inspection system. Mixed foreign material on the corroded part is assumed and the laser ultrasonic experiment is conducted. An ultrasonic wave is generated by pulse laser from the back of the specimen and an ultrasonic signal is acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer (CFPI). The characteristic of the ultrasonic signal of existing foreign material is analyzed and the location and size of foreign material is measured.

Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method (압전형 수신 기법을 이용한 초음파 절대변위진폭 측정)

  • Park, Seong-Hyun;Kim, Jongbeom;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

A Study on Nondestructive Technique Using Laser Technique for Evaluation of Carbon fiber Reinforced Plastic (레이저를 이용한 탄소섬유강화 복합재료의 비파괴평가 기법에 관한 연구)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Byun, Joon-Hyung;Seo, Kyeong-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.103-109
    • /
    • 2005
  • Fiber reinforced plastic material should be inspected in fabrication process in order to enhance quality by prevent defects such as delamination and void. Generally, ultrasonic technique is widely used to evaluate FRP. In conventional ultrasonic techniques, transducer should be contacted on FRP. However, conventional contacting method could not be applied in fabrication process and novel non-contact evaluating technique was required. Laser-based ultrasonic technique was tried to evaluate CFRP plate. Laser-based ultrasonic waves propagated on CFRP were received with various transducers such as accelerometer and AE sensor in order to evaluate the properties of waves due to the variation of frequency. Velocities of laser-based ultrasonic waves were evaluated for various fiber orientation. In addition, laser interferometry was used to receive ultrasonic wave in CFRP and frequency was analysed.

A rapid assessment methodology for bridges damaged by truck strikes

  • Stull, C.J.;Earls, C.J.
    • Steel and Composite Structures
    • /
    • v.9 no.3
    • /
    • pp.223-237
    • /
    • 2009
  • The present research aims to develop a methodology to rapidly assess bridges with damage to the superstructure, caused by overheight trucks or lower-than-average overhead clearance. Terrestrial laser scanning and image processing techniques are combined with the finite element method to arrive at an analytical model which is more accurate, with respect to the complex geometrical aspects of the bridge in its damaged configuration. ""Virtual load testing"" may subsequently be carried out on this analytical model to determine the reserve capacity of the structure in an objective manner.

Advances in Damage Visualization Algorithm of Ultrasonic Propagation Imaging System

  • Lee, Jung-Ryul;Sunuwar, Nitam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.232-240
    • /
    • 2013
  • This paper presents recent advances in damage visualization algorithms of laser generated ultrasonic propagation imaging(UPI) system. An effective damage evaluation method is required to extract correct information from raw data to properly characterize anomalies present in structure. A temporal-reference free imaging system provides easy and rapid defect inspection capability with less computational complexity. In this paper a number of methods such as ultrasonic wave propagation imaging(UWPI), anomalous wave propagation imaging(AWPI), ultrasonic spectral imaging(USI), wavelet ultrasonic propagation imaging(WUPI), variable time window amplitude mapping(VTWAM), time point adjustment(TPA), time of flight and amplitude mapping(ToF&Amp) and ultrasonic wavenumber imaging(UWI) are discussed with instances of successful implementation on various structures.

Development of Multi-Laser Vision System For 3D Surface Scanning (3 차원 곡면 데이터 획득을 위한 멀티 레이져 비젼 시스템 개발)

  • Lee, J.H.;Kwon, K.Y.;Lee, H.C.;Doe, Y.C.;Choi, D.J.;Park, J.H.;Kim, D.K.;Park, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.768-772
    • /
    • 2008
  • Various scanning systems have been studied in many industrial areas to acquire a range data or to reconstruct an explicit 3D model. Currently optical technology has been used widely by virtue of noncontactness and high-accuracy. In this paper, we describe a 3D laser scanning system developped to reconstruct the 3D surface of a large-scale object such as a curved-plate of ship-hull. Our scanning system comprises of 4ch-parallel laser vision modules using a triangulation technique. For multi laser vision, calibration method based on least square technique is applied. In global scanning, an effective method without solving difficulty of matching problem among the scanning results of each camera is presented. Also minimal image processing algorithm and robot-based calibration technique are applied. A prototype had been implemented for testing.

  • PDF

CARIES PREDICTION MODEL USING LASER FLUORESCENCE (레이저 형광법을 이용한 우식유발 예측모형)

  • Lee, Sang-Ho;Lee, Chang-Seop;Jeong, Yeon-Hwa
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.16-24
    • /
    • 2001
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using laser fluorescence. The subjects of this study were 50 children of $7\sim9$ years old. Fluorescence from initial carious lesion of teeth illuminated by an argon laser(480nm) was observed and photographed with barrier filter. Visual examination for the dDfFtT rate and Streptococcus mutans colony counting was done to evaluate correlation with caries activity test using laser fluorescence. Data analysis was accomplished by Axelsson's method. The results from the present study can be summarized as follows: 1. There was positive correlation $(\gamma=0.48)$ between laser fluorescence test and Streptococcus mutans count. And also positive correlation $(\gamma=0.39)$ exists between laser fluorescence test and dDfFtT rate (P<0.01). 2. Positive correlation $(\gamma=0.27)$ between Streptococcus mutans colony count and dDfFtT rate was found(P<0.05). 3. When dDfFtT rate was defined to standard testing method, the specificity, senstivity, and diagnostic power of laser fluorescence test were 44.4%, 85.7%, and 87.8%. 4. When dDfFtT rate was defined to standard testing method, the specificity, senstivity, and diagnostic power of S. mutans colony counting were 77.8%, 92.9%, 84.8%. 5. When S. mutans colony counting was defined to standard testing method, sensitivity, specificity and diagnostic power of laser fluorescence test were 40.0%, 84.8%, 95.1%. In regard to above results, laser fluorescence test considered to be accurate and reliable method for determining caries activity because of it's close relationship with caries susceptibility test and caries experience measurements. And it was also considered to be practical because it would be simple, inexpensive, and time saving method.

  • PDF