• Title/Summary/Keyword: Laser Surface Treatment

Search Result 328, Processing Time 0.032 seconds

The effect of blasting and anodizing-combined treatment of implant surface on response of osteoblast-like cell (분사처리 후 양극산화 처리한 임플란트 표면이 골모 유사 세포의 반응에 미치는 영향)

  • Seo, Bo-Yong;Kim, Young-Min;Choi, Jae-Won;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Kim, Gyu-Cheon;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.9-18
    • /
    • 2015
  • Purpose: The purpose of this study is to examine characteristics of implant surface with RBM and anodizing treatments, and to evaluate the responses of osteoblast-like cell (MG-63 cell). Materials and methods: Grade IV titanium disks were fabricated (Diameter 10 mm, thickness 3 mm). Anodizing treatment (ASD) group, RBM and anodizing treatment (RBM/ASD) group, control (machined surface) group were divided. In this study, osteoblast-like cell was used for experiments. The experiments consist of surface characteristics evaluation by FE-SEM images, energy dispersive spectroscopy and stereo-SEM. In order to evaluate cell adhesion evaluation by crystal violet assay and observe cells form by confocal laser microscopy. To assess cell proliferation by XTT assay, cell differentiation by RT-PCR and mineralization by Alizarin red S stain assay. ELISA analyzer was used for Quantitative evaluation. Comparative analysis was run by one-way ANOVA (SPSS version 18.0). Differences were considered statistically significant at P<.05. Results: In ASD group and RBM/ASD group, the surface shape of the crater was observed and components of oxygen and phosphate ions in comparison with the control group were detected. The surface average roughness was obtained $0.08{\pm}0.04{\mu}m$ in the control group, $0.52{\pm}0.14{\mu}m$ in ASD group and $1.45{\pm}0.25{\mu}m$ in RBM/ASD group. In cell response experiments, ASD group and RBM/ASD group were significantly higher values than control group in cell adhesion and mineralization phase, control group was the highest values in the proliferative phase. In RT-PCR experiments, RBM/ASD group was showed higher ALP activity than other groups. RBM/ASD group in comparison with ASD group was significantly higher value for cell adhesion and proliferation phase. Conclusion: In the limitation of this study, we are concluded that the surface treatment with RBM/ASD seems more effective than ASD alone or machined surface on cellular response.

THE EFFECT OF VARIOUS SURFACE TREATMENT METHODS ON THE OSSEOINTEGRATION (임플랜트의 표면처리 방법이 골유착에 미치는 영향에 관한 연구)

  • Choi Jeong-Won;Kim Kwang-Nam;Heo Seong-Joo;Chang Ik-Tae;Han Chong-Hyun;Baek Hong-Gu;Choi Yong-Chang;Wennerberg Ann
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.71-83
    • /
    • 2001
  • The purpose of this study was to compare the effects of various surface treatments by measuring removal torque on bone healing around titanium implants. 40 Screw-shaped cp titanium implants with length of 4mm, outer diameter of 3.75mm, and pitch-height of 0.5mm were used Group 1 was left as machined(control), Group 2 was blasted with $50{\mu}m\;Al_2O_3$, group 3 was blasted and etched in etching solution($NH_4OH : H_2O_2:H_2O= 1 : 1 : 5$) at $90^{\circ}C$ for 1 minute group 4 was blasted and oxidated under pure oxygen at $800^{\circ}C$. The implant surface roughness was analyzed with SEM and CLSM(Confocal Laser Scanning Microscope) and implants were placed in proximal tibial metaphysis of 10 New Zealand White rabbits. After 3 months of healing period, removal torque of each implant was measured to compare bone healing around implant. The results obtained were as follows 1. In SEM view, blasting increased the roughness of the surface, but etching of that rough surface decreased the roughness due to the removal of the tip of the peak. Oxidation also decreased the roughness due to formation of needle-like oxide grains on the implant surface. 2. The Sa value from CLSM was least in the machined group($0.47{\mu}m$), greatest in blasted group($1.25{\mu}m$), and the value decreased after etching($0.91{\mu}m$) and oxidation($0.94{\mu}m$). 3. The removal torque of etched group(24.5Ncm) was greater than that of machined group(16.7Ncm) (P<0.05), and was greatest in the oxidated group(40.3Ncm) and the blasted group(34.7Ncm).

  • PDF

In-situ rf treatment of multiwall carbon nanotube with various post techniques for enhanced field emission

  • Ahn, Kyoung-Soo;Kim, Jun-Sik;Kim, Ji-Hoon;Kim, Chae-Ok;Hong, Jin-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.859-862
    • /
    • 2003
  • Well-aligned multiwall carbon nanotubes (MWCNTs) were prepared at low temperature of 400 $^{\circ}C$ by utilizing a radio frequency plasma-enhanced chemical vapor deposition (rf-PECVD) system. The MWCNTs were treated by an external rf plasma source and an ultra-violet laser in order to modify structural defect of carbon nanotube and to ablate possible contamination on carbon nanotube surface. Structural properties of carbon nanotubes were investigated by using a scanning electron microscopy (SEM), Raman spectroscopy, Fourier transformer Infrared spectroscopy (FTIR) and transmission electron microscope (TEM). In addition, the emission properties of the MWNTs were measured for the application of field emission display (FED) in near future. Various post treatments were found to improve the field emission property of carbon nanotubes.

  • PDF

Performance of Hot-dip Zn-6%Al-3%Mg Alloy Coated Steel Sheet as Automotive Body Material

  • Shimizu, Takeshi;Asada, Hiroshi;Morikawa, Shigeru
    • Corrosion Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.74-80
    • /
    • 2010
  • For the purpose of applying a hot-dip Zn-6mass%Al-3mass%Mg alloy coated steel sheet (ZAM) to automotive body materials, a laboratory study of the general properties required for inner and outer panels of automotive bodies was performed. Even with only light coating weight, ZAM showed an excellent corrosion resistance in terms of both cosmetic and perforation corrosion compared to the currently used materials for automotive bodies, GI70 and GA45. In our study, it was confirmed that ZAM exhibits as good as or better properties than GI70 in terms of spot weldability and press formability. Furthermore, since the same corrosion resistance can be achieved with less coating weight by applying ZAM, laser weldability is better than GI and GA.

Equipment Manufacturing of Lamp Heating to Fabricate Selective Emitter Silicon Solar Cell (선택적 에미터 결정질 실리콘 태양전지 제작을 위한 할로겐 램프 장치 개발)

  • Han, Kyu-Min;Choi, Sung Jin;Lee, Hi-Deok;Song, Hee-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.102-107
    • /
    • 2012
  • Halogen lamp was applied to fabricate the selective emitter crystalline silicon solar cell. In selective emitter structure, the recombination of minority carriers is reduced with heavily doped emitter under metal grid, consequently improving the conversion efficiency. Laser selective emitter process which is recently used the most generally induces the damage on the silicon surface. However the lamp has enough heat to form heavily doped emitter layer by diffusing phosphorus from PSG without surface damage. In this work, we have studied to find the design and the suitable condition for halogen lamp such as power, time, temperature and figured out the possibility to fabricate the selective emitter silicon solar cell by lamp heating. The sheet resistance with $100{\Omega}/{\Box}$ was lower to $50{\Omega}/{\Box}$ after halogen lamp treatment. Heat transfer to lightly doped emitter region was blocked by using the shadow mask.

Study of the capability of metallic coils immersed with protein solution as embolic masterials (색전용 금속 코일 개발과 단백질 처리 후 혈전성에 대한 연구)

  • Lee, Y.S.;Kim, T.S.;Kim, H.C.;Shin, K.M.;Park, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.347-349
    • /
    • 1997
  • In this study, we designed a vascular occlusion device based on the principle that slowing blood flow would induce thrombosis. Tungsten, stainless steel and platinum were tested for finding a good embolic metallic coil. The primary coil and the second coil were done with heat treatment or different time. The pitch distance and the shape retention capability of second coil were characterized by SEM. To increase thrombogenicity, we tried to treat different proteins on steel coils: thrombin, gelatin and both gelatin and thrombin. To verify protein materials treated on coils, the surface of coil treated with different proteins were characterized using Laser Raman Spectrophotometer. After observation of embolic coils, the peptides bonds on theirs' surface were found. In order to compare the thrombogenicity of different embolic agents, we measured whole blood clotting time.

  • PDF

Fabrication, Optoelectronic and Photocatalytic Properties of Some Composite Oxide Nanostructures

  • Zou, C.W.;Gao, W.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • This is an overview paper reporting our most recent work on processing and microstructure of nano-structured oxides and their photoluminescence and photo-catalysis properties. Zinc oxide and related transition metal oxides such as vanadium pentoxide and titanium dioxide were produced by a combination of magnetron sputtering, hydrothermal growth and atmosphere controlled heat treatment. Special morphology and microstructure were created including nanorods arrays, core-brushes, nano-lollipops and multilayers with very large surface area. These structures showed special properties such as much enhanced photoluminescence and chemical reactivity. The photo-catalytic properties have also been promoted significantly. It is believed that two factors contributed to the high reactivity: the large surface area and the interaction between different oxides. The transition metal oxides with different band gaps have much enhanced photoluminescence under laser stimulation. Use of these complex oxide structures as electrodes can also improve the energy conversion efficiency of solar cells. The mixed oxide complex may provide a promising way to high-efficiency photo emitting materials and photo-catalysts.

Direct membrane filtration of wastewater under very short hydraulic retention time

  • Yoon, Seong-Hoon
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.39-52
    • /
    • 2018
  • Direct membrane filtration (DMF) of wastewater has many advantages over conventional biological wastewater treatment processes. DMF is not only compact, but potentially energy efficient due to the lack of biological aeration. It also produces more biosolids that can be used to produce methane gas through anaerobic digestion. Most of ammoniacal nitrogen in wastewater is preserved in effluent and is used as fertilizer when effluent is recycled for irrigation. In this study, a technical feasibility of DMF was explored. Organic and nitrogen removal efficiencies were compared between DMF and membrane bioreactor (MBR). Despite the extremely high F/V ratio, e.g., $14.4kg\;COD/m^3/d$, DMF provided very high COD removal efficiencies at ~93%. Soluble microbial products (SMP) and extracellular polymeric substances (EPS) were less in DMF sludge, but membrane fouling rate was far greater than in MBR. The diversity of microbial community in DMF appeared very narrow based on the morphological observation using optical microscope. On the contrary, highly diverse microbial community was observed in the MBR. Microorganisms tended to form jelly globs and attach on reactor wall in DMF. FT-IR study revealed that the biological globs were structurally supported by feather-like materials made of secondary amines. Confocal laser scanning microscopy (CLSM) study showed microorganisms mainly resided on the external surface of microbial globs rather than the internal spaces.

Use of modern microscopes in Analyzing fiber and Paper Properties( I )-Use of CLSM in Analyzing Fiber and Paper Properties- (최신 현미경을 이용한 섬유 및 종이의 성질 분석(제1보)-Confocal Laser Scanning Microscope를 이용한 섬유 밑 종이의 성질 분석-)

  • ;Keith Roy Wadhams
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.1
    • /
    • pp.7-17
    • /
    • 1998
  • With the advent of CLSM in the end of 1980s, it has been applied to the field of pulp and paper science in various ways. This study showed the potentials of CLSM In analyzing a change of pulp fiber and paper properties before and after mechanical treatment. In particular, a quantification of internal fibrillation has been done using cross-sectional images of fibers and image analysis technique, then evaluated the effects of fiber wall delamination on fiber and paper properties. It showed that the delaminated fibers were closely associated to development of the interfiber bonding in a fiber network. The CLSM made it possible to investigate a density profile along the sheet thickness, which was created by some papermaking processes like pressing, drying and calendering. Through the attempt to observe the forming procedure of a fiber network during handsheet making, the CLSM images showed that the pressing stage was considered greatly to contribute to generation of interfiber bonding with removing a free water and partly a bound water between fibers. In addition, the CLSM could be used to illustrate not only a surface profile of paper showing the extent of smoothness or roughness, but also a density profile in a B-direction of the network. Finally it became evident that the CLSM could be used as an excellent tool to predict development in fiber and paper properties before and after mechanical treatment during papermaking processes.

  • PDF

Detection and Prognostic Analysis of Serum Protein Expression in Esophageal Squamous Cell Cancer

  • Jiang, Hong;Wang, Xiao-Hong;Yu, Xin-Min;Zheng, Zhi-Guo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1579-1582
    • /
    • 2012
  • Objective: To assess differences in serum proteins in esophageal squamous cell carcinoma patients. Methods: 144 esophageal squamous cell carcinoma patients and 50 healthy volunteers were included in this study, with surface-enhanced laser desorption-ionization time-of-flight mass spectrometry and weak cation exchange magnetic beads. Follow-up allowed the relations between serum proteins and prognosis to be analyzed. Results: A total of 93 protein peaks were detected (molecular weight range: 1500-30000), 10 demonstrating statistically significant differences. There were no differences in protein peaks between 92 patients with a survival more than 2 years and 52 patients with survival less than 2 years. There were two significantly different protein peaks between 45 stage II patients with a survival more than 2 years and 14 stage II patients with survival less than 2 years. There was one significantly different protein peak between 22 stage III patients with a survival more than 2 years and 29 stage III patients with survival less than 2 years. Conclusion: Differences of serum proteins in esophageal squamous cell carcinoma are related to prognosis of patients. The protein fingerprint can be helpful for clinical diagnosis and treatment.