• Title/Summary/Keyword: Laser Scanning Microscope

Search Result 323, Processing Time 0.026 seconds

A confocal microscopic study of dentinal infiltrations in one-bottle adhesive systems bonded to Class V cavities

  • Kim, Hyung-Su;Park, Sung-Ho
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.576.2-576
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of dentinal sclerosis and tubular orientation on Class V restoration bonded with three dentin bonding agents using confocal laser scanning microscope(CLSM). Class V cavities were prepared from freshly extracted caries-free human teeth. thirty of these cavities were divided into two groups based upon the status of class V cavities: Group 1, cervical abrasive lesions without preparation; Group 2, artificially-prepared wedge-shaped cavities.(omitted)

  • PDF

Microprocess of silicon using focused Ar$^+$ llaser and estimates (집속된 아르곤 이온 레이저에 의한 실리콘의 미세가공 및 평가)

  • Cheong, Jae-Hoon;Lee, Cheon;Hwang, Kyoung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.473-476
    • /
    • 1997
  • Focused Ar ion laser beam can be utilized to fabricate microstructures on silicon substrate as well as other materials(e.g. such as ceramic). The laser using in this study is an argon ion laser with maximum power of 6 W, wavelength of 514 nm. This laser beam is focused by objectives with a high numerical aperture, a long working distance. We have achieved line width about 1 ${\mu}{\textrm}{m}$ with high scan speed. The resolution for Si machining is determined by the selectivity of the chemical reaction rather than the laser spot size. In this study, we have obtained the maximum etch rate of 434.7 ${\mu}{\textrm}{m}$/sec with high aspect ratio. The characteristics of etched groove was investigated by scanning electron microscope(SEM) and auger electron spectroscopy(AES). It is assumed that the technique using arson ion laser is applicab1e to fabricate microstructures.

  • PDF

Laser-Induced Recrystallization of Perovskite Materials for High-Performance Flexible Light-Emitting Diode (고성능 유연 발광 다이오드 소자 구현을 위한 레이저 기반 페로브스카이트 소재의 재결정화)

  • Jae Chan Heo;Ji Eun Kim;Dong Gyu Lee;Yun Sik Hwang;Yu Mi Woo;Han Eol Lee;Jung Hwan Park
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.286-291
    • /
    • 2023
  • Perovskite materials are promising candidates for next-generation optoelectronic devices owing to their outstanding external quantum efficiency, high color purity, and ability to tune the light emission wavelength. However, conventional thermal annealing processes caused the degradation of perovskite, resulting in poor optoelectronic properties and a short lifetime. Herein, we propose a laser-induced recrystallization of perovskite thin film to enhance its light-emitting properties. Laser-induced recrystallization process was performed using rapid and instantaneous laser heating, which successfully induced grain growth of the perovskite material. The laser processing conditions were thoroughly optimized based on theoretical calculations and various material analyses such as x-ray diffraction, scanning electron microscope, and photoluminescence spectroscopy.

Optical Characterization of Sensory Rhodopsin II Thin Films using a Near-field Scanning Microwave Microscope (근접장 마이크로파 현미경을 이용한 로돕신의 광학적 특성 연구)

  • Yu, Kyung-Son;Kim, Song-Hui;Yoon, Young-Woon;Lee, Kie-Jin;Lee, Jung-Ha;Choi, Ah-Reum;Jung, Kwang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.80-85
    • /
    • 2007
  • We report the electro-optical properties of the sensory rhodopsin II using a near-field scanning microwave microscope(NSMM). Rhodopsin was known as a photoreceptor pigment with a retinal as a chromophore via a protonated Schiff base and consists of seven ${\alpha}-helical$ transmembrane segments. The sensory rhodopsin II, expressing E. coli UT5600 with endogenous retinal biosynthesis system and purified with $Ni^{-2}-NTA$ affinity chromatography in the presence of 0.02 % DM (Dodecyl Maltoside) from Natronomonas pharaonis. We measured the absorption spectra and the transients difference of sensory rhodopsin II from Natronomonas pharaonis using a UV/VIS spectrophotometer with Nd-Yag Laser (532 nm). The absorption spectra of NpSR II showed a typical rhodopsin spectrum with a left shoulder region and the photointermediates spectra of NpSR II-ground state (${\lambda}max=498\;nm$), NpSR II-M state (${\lambda}max=390\;nm$), and NpSR II-O state (${\lambda}max=550\;nm$) during the photocycle. The observed photocycle reaction was confirmed by measuring the microwave reflection coefficient $S_{11}$ at an operating frequency of f=3.93-3.95 GHz and compared with the results of a photocycle of NpSR II.

Measurement of the Thermal Conductivity of a Polycrystalline Diamond Thin Film via Light Source Thermal Analysis

  • Kim, Hojun;Kim, Daeyoon;Lee, Nagyeong;Lee, Yurim;Kim, Kwangbae;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.31 no.12
    • /
    • pp.665-671
    • /
    • 2021
  • A 1.8 ㎛ thick polycrystalline diamond (PCD) thin film layer is prepared on a Si(100) substrate using hot-filament chemical vapor deposition. Thereafter, its thermal conductivity is measured using the conventional laser flash analysis (LFA) method, a LaserPIT-M2 instrument, and the newly proposed light source thermal analysis (LSTA) method. The LSTA method measures the thermal conductivity of the prepared PCD thin film layer using an ultraviolet (UV) lamp with a wavelength of 395 nm as the heat source and a thermocouple installed at a specific distance. In addition, the microstructure and quality of the prepared PCD thin films are evaluated using an optical microscope, a field emission scanning electron microscope, and a micro-Raman spectroscope. The LFA, LaserPIT-M2, and LSTA determine the thermal conductivities of the PCD thin films, which are 1.7, 1430, and 213.43 W/(m·K), respectively, indicating that the LFA method and LaserPIT-M2 are prone to errors. Considering the grain size of PCD, we conclude that the LSTA method is the most reliable one for determining the thermal conductivity of the fabricated PCD thin film layers. Therefore, the proposed LSTA method presents significant potential for the accurate and reliable measurement of the thermal conductivity of PCD thin films.

Variation of Structural and Optical Properties of ZnO Nanorods with Growing Time (성장시간에 따른 ZnO 나노로드의 구조적 및 광학적 특성 변화)

  • Ma, Tae-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.841-846
    • /
    • 2016
  • ZnO nanorods were grown on $SiO_2$ coated Si wafers and glass by the hydrothermal method. The structural and optical properties variation of ZnO nanorods as a function of growing time was studied. ~10 nm-thick ZnO thin films deposited on substrates by rf magnetron sputtering were employed as seed layers. Zinc nitrate hexahydrate (0.05 M) and hexamethylenetetramine (0.05 M) mixed in DI water were used as a reaction solution. ZnO nanorods were respectively grown for 30 min, 1 h, 2 h, 3 h, and 4 h by maintaining the reactor at $90^{\circ}C$. Crystallinity of ZnO nanorods was analyzed by X-ray diffraction, and the morphology of nanorods was observed by a field emission scanning electron microscope. Transmittance and absorbance were measured by a UV-Vis spectrophotometer, and energy band gap and urbach energy were obtained from the data. Photoluminescence measurements were carried out using Nd-Yag laser (266 nm).

Thermal Design and Batch Fabrication of Full SiO2 SThM Probes for Sensitivity Improvement (주사탐침열현미경의 감도향상을 위한 전체 실리콘 산화막 열전탐침의 열적설계 및 일괄제작)

  • Jaung, Seung-Pil;Kim, Kyeong-Tae;Won, Jong-Bo;Kwon, Oh-Myoung;Park, Seung-Ho;Choi, Young-Ki;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.10
    • /
    • pp.800-809
    • /
    • 2008
  • Scanning Thermal Microscope (SThM) is the tool that can map out temperature or the thermal property distribution with the highest spatial resolution. Since the local temperature or the thermal property of samples is measured from the extremely small heat transferred through the nanoscale tip-sample contact, improving the sensitivity of SThM probe has always been the key issue. In this study, we develop a new design and fabrication process of SThM probe to improve the sensitivity. The fabrication process is optimized so that cantilevers and tips are made of thermally grown silicon dioxide, which has the lowest thermal conductivity among the materials used in MEMS. The new design allows much higher tip so that heat transfer through the air gap between the sample-probe is reduced further. The position of a reflector is located as far away as possible to minimize the thermal perturbation due to the laser. These full $SiO_2$ SThM probes have much higher sensitivity than that of previous ones.

Effects of Pulsed Nd:YAG Laser Irradiation and Fluoride Compound Application on Surface Hardness of Incipient Carious Lesion in Enamel of Bovine Teeth (Pulsed Nd : YAG 레이저 조사와 불소 화합물 도포가 초기 우식 법랑질의 표면 경도에 미치는 영향)

  • Jun-Bong Kwag;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.207-224
    • /
    • 1996
  • This study was designed to determine the most effective concentration of fluoride and energy density of laser irradiation for the anticarious effect. For this study surface hardness in enamel was measured before and after irradiation with pulsed Nd;YAG laser and the topical application of fluoride. Of the permanent mandibular anterior hovine teeth, healthy, carious free ones were used. Three hundred specimens were made. Specimens within 25~45 Vickers hardness numbers were assigned to 20 control and experimental stoops ; each containing 15 specimens. After forming artificial carious lesions, 10 J/$\textrm{cm}^2$, 20 J/$\textrm{cm}^2$, and 30 J/$\textrm{cm}^2$ energies were irradiated on the enamel surface of each experimental group. Also NaF, NH4F, Elmex gel(amine fluoride) and APF gel fluoride compounds were applied topically. Next, all the specimens were placed into the pH circulatory procedures for eight days. Vickers hardness numbers were measured using a microhardness tester. Surface changes of the enamel were observed using an scanning electron microscope. The comparative ana1ysis yielded the following results : 1. The reduction of surface hardness of the enamel surface was less in all groups with fluoride application than in the group without fluoride application. 2. The APF gel croup with 10 J/$\textrm{cm}^2$ irradiation showed the lowest reduction of surface hardness. 3. The reduction of surface hardness of the enamel surface in the group of laser irradiation without fluoride application not showed any significant difference according to the energy density of the laser. 4. Under the scanning electron microscope, in enamel irradiated with 10J/$\textrm{cm}^2$ showed appearance similar to acid etching surface. In enamel irradiated with 20 J/$\textrm{cm}^2$, line enamel crack was detected. In enamel irradiated with 30j/$\textrm{cm}^2$, severe enamel crack and fusion of enamel were detected. These results suggest that one could obtain the best anticariogenic effects without damage to teeth in the group of application of APF gel after laser irradiation with 10 J/$\textrm{cm}^2$.

  • PDF

Study on super-hydrophobic electro-spray micro thruster and measurement of micro scale thrust (초소수성 전기 분무 마이크로 추진 장치 및 마이크로 추력 측정)

  • Lee, Young-Jong;Yoo, Yong-Hoon;Tran, Si Bui Quang;Kim, Sang-Hoon;Park, Bae-Ho;Buyn, Do-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.175-180
    • /
    • 2009
  • In this article, we fabricated polytetrafluoroethylene(PTFE) nozzle treated by ion beam, in order to fabricate polymer based electrospray micro thruster with super hydrophobic nozzle. To obtain the super hydrophobic surface, PTFE surface is treated by argon and oxygen plasma treatment process. The optimal condition is investigated argon and oxygen flow rate as well as the paalied energy level for the treatment process. Fabricated nozzle was evaluated by measuring contact angle, and the surface morphology was examined by using scanning electron microscope(SEM) and atomic force microscope(AFM). We observe that jetting becomes more stable and repeatable on the treated nozzle. And to evaluate performance of fabricated nozzle, we measure micro scale thrust using a cantilever and a nozzle treated by ion beam laser displacement sensor.

Evaluation of titanium surface properties by $Nd:YVO_4$ laser irradiation: pilot study ($Nd:YVO_4$ 레이저 조사에 따른 티타늄의 표면특성 평가: 예비 연구)

  • Kim, Ae-Ra;Park, Ji-Yoon;Kim, Yeon;Jun, Sei-Won;Seo, Yoon-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.167-174
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the roughness and surface alternations of three differently blasted titanium discs treated by $Nd:YVO_4$ Laser irradiation in different conditions. Materials and methods: Thirty commercially pure titanium discs were prepared and divided into three groups. Each group was consisted of 10 samples and blasted by $ZrO_2$ (zirconium dioxide), $Al_2O_3$ (aluminum oxide), and RBM (resorbable blasted media). All the samples were degreased by ultrasonic cleaner afterward. Nine different conditions were established by changing scanning speed (100, 300, 500 mm/s) and repetition rate (5, 15, 35 kHz) of $Nd:YVO_4$ Laser (Laser Pro D-20, Laserval $Korea^{(R)}$, Seoul, South Korea). After laser irradiation, a scanning electron microscope, X-ray diffraction analysis, energy dispersive X-ray spectroscopic analysis, and surface roughness analysis were used to assess the roughness and surface alternations of the samples. Results: According to a scanning electron microscope (SEM), titanium discs treated with laser irradiation showed characteristic patterns in contrast to the control which showed irregular patterns. According to the X-ray diffraction analysis, only $Al_2O_3$ group showed its own peak. The oxidation tendency and surface roughness of titanium were similar to the control in the energy dispersive X-ray spectroscopic analysis. The surface roughness was inversely proportional to the scanning speed, whereas proportional to the repetition rate of $Nd:YVO_4$. Conclusion: The surface microstructures and roughness of the test discs were modified by the radiation of $Nd:YVO_4$ laser. Therefore, laser irradiation could be considered one of the methods to modify implant surfaces for the enhancement of osseointegration.