• Title/Summary/Keyword: Laser Fabrication

Search Result 863, Processing Time 0.028 seconds

Design and Fabrication of DWDM Multiplexer Using Optical Fiber Biconical Tapered Couplers (광섬유 용융인장 방법에 의한 DWDM용 광다중화기의 제작)

  • Chang, Jin-Hyeon;Kim, Myoung-Saeng;Kang, Duk-Keun
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.2
    • /
    • pp.51-60
    • /
    • 2004
  • In this paper, 8-channel multiplexer with 100GHz channel spacing is fabricated. The 8-channel multiplexer is fabricated by connecting three cascaded Mach Zehnder Interferometer (MZI) of optical fiber type, and each interferometer has the wavelength interval of 100GHz, 200GHz and 400GHz, respectively. furthermore, to acquire uniform insertion loss, it is fabricated by using Wavelength Flatten Coupler (WFC) in which the variation of insertion loss is low. Especially, the variation of wavelength interval in the output is explicitly simulated as a function of optical path difference, and the wavelength coupling process along with cascaded connection is discussed. $CO_2$ laser to adjust precisely the wavelength. In summary, The prototype composed by eight cascaded MZI has an insertion loss of 2.1dB, the bandwidth of 0.8nm at 5.5dB point, and channel crosstalk of 25dB Furthermore, the loss dependent on polarization is measured as 0.06dB.

  • PDF

Fabrication of Coated Conductor by Continuous PVD Methods (연속 공정 PVD 방법에 의한 Coated Conductor 제조)

  • Ko, Rock-Kil;Chung, Jun-Ki;Kim, Ho-Sup;Ha, Hong-Soo;Shi, Dongqi;Song, Kyu-Jeong;Park, Chan;Yoo, Sang-Im;Moon, Seung-Hyun;Kim, Young-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1241-1245
    • /
    • 2004
  • Continuous physical vapor deposition (PVD) method is one of many processes to fabricate long length coated conductor which is required for successful large-scale application of superconducting power devices. Three film deposition systems (pulsed laser deposition, sputtering, and evaporation) equipped with reel-to-reel(R2R) metal tape moving apparatus were installed and used to deposit multi-layer oxide thin films. Both RABiTS and IBAD texture templates are used. IBAD template consists of CeO$_2$(PLD)/YSZ(IBAD) on stainless steel(SS) metal tape, and RABiTS template has the structure of CeO$_2$/YSZ/Y$_2$O$_3$ which was continuously deposited on Ni-alloy tape using R$_2$R evaporation and DC reactive sputtering in a deposition system designed to do both processes. 0.4 m-long coated conductor with Ic(77 K) of 34 A/cm was fabricated using RABiTS template. 0.5 m and 1.1 m-long coated conductor with Ic(77 K) of 41 A/cm and 26 A/cm were fabricated using IBAD template.

Selective Growth of Nanosphere Assisted Vertical Zinc Oxide Nanowires with Hydrothermal Method

  • Lee, Jin-Su;Nam, Sang-Hun;Yu, Jung-Hun;Yun, Sang-Ho;Boo, Jin-Hyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.252.2-252.2
    • /
    • 2013
  • ZnO nanostructures have a lot of interest for decades due to its varied applications such as light-emitting devices, power generators, solar cells, and sensing devices etc. To get the high performance of these devices, the factors of nanostructure geometry, spacing, and alignment are important. So, Patterning of vertically- aligned ZnO nanowires are currently attractive. However, many of ZnO nanowire or nanorod fabrication methods are needs high temperature, such vapor phase transport process, metal-organic chemical vapor deposition (MOCVD), metal-organic vapor phase epitaxy, thermal evaporation, pulse laser deposition and thermal chemical vapor deposition. While hydrothermal process has great advantages-low temperature (less than $100^{\circ}C$), simple steps, short time consuming, without catalyst, and relatively ease to control than as mentioned various methods. In this work, we investigate the dependence of ZnO nanowire alignment and morphology on si substrate using of nanosphere template with various precursor concentration and components via hydrothermal process. The brief experimental scheme is as follow. First synthesized ZnO seed solution was spun coated on to cleaned Si substrate, and then annealed $350^{\circ}C$ for 1h in the furnace. Second, 200nm sized close-packed nanospheres were formed on the seed layer-coated substrate by using of gas-liquid-solid interfacial self-assembly method and drying in vaccum desicator for about a day to enhance the adhesion between seed layer and nanospheres. After that, zinc oxide nanowires were synthesized using a low temperature hydrothermal method based on alkali solution. The specimens were immersed upside down in the autoclave bath to prevent some precipitates which formed and covered on the surface. The hydrothermal conditions such as growth temperature, growth time, solution concentration, and additives are variously performed to optimize the morphologies of nanowire. To characterize the crystal structure of seed layer and nanowires, morphology, and optical properties, X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, and photoluminescence (PL) studies were investigated.

  • PDF

Fabrication of Transient Absorption Spectroscopic System and Measurement of Transient Absorption Changes of DDI (순간흡수 분광학 측정장치 구성 및 DDI의 순간흡수율 변화 측정)

  • Seo, Jung-Chul;Lee, Min-Yung;Kim, Dong-Ho;Jeong, Hong-Sik;Park, Seung-Han;Kim, Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.209-213
    • /
    • 1991
  • Recently, the developments in generating and amplifying ultrashort optical pulses $(ps=10^{-12}s or fs=10^{-15}s)$ have imposed on great advances in the time-resolved laser spectroscopy. Especially, the transient absorption spectroscopy has a wide application range and the main idea of this technique is pump & probe method. After the pump pulse makes the material an excited or a transient states, the probe pulse is sent through the material to measure the absorbance change due to the transient states. Here, if the absorbance change was measured by the time delay between pump & probe pulses, the dynamic information of the excited or the transient states (the transient abnsorption changes by time & wavelength) can be obtained. At our laboratory, the ultrashort optic1 pulse (

  • PDF

A case of digital maxillary complete denture and mandibular implant overdenture fabricated by CAD-CAM technique (완전 무치악 환자에서 CAD-CAM 기법을 이용한 상악 총의치 및 하악 임플란트 피개의치 수복: 증례 보고)

  • Kim, Kun Min;Oh, Kyung Chul;Kim, Sang Hyun;Han, Chol Gwan;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.442-450
    • /
    • 2021
  • The CAD-CAM technique is a rapidly developing field in the dental field and is applied to various fields of prosthetic treatment. Among them, the manufacturing of dentures using the milling technique classified as subtractive manufacturing is one of the commercialized digital full denture manufacturing methods. At the same time, it is possible to more efficiently manufacture a metal framework for implant overdenture by selective laser sintering or melting technique classified as an additive manufacturing method. The purpose of this article is to describe the fabrication of CAD-CAM maxillary complete denture and mandibular implant overdenture as well as its features.

Parallel pattern fabrication on metal oxide film using transferring process for liquid crystal alignment (전사 공정을 이용한 산화막 정렬 패턴 제작과 액정 배향 특성 연구)

  • Oh, Byeong-Yun
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.594-598
    • /
    • 2019
  • We demonstrate an alternative alignment process using transferring process on solution driven HfZnO film. Parallel pattern is firstly fabricated on a silicon wafer by laser interference lithography. Prepared HfZnO solution fabricated by sol-gel process is spin-coated on a glass substrate. The silicon wafer with parallel pattern is placed on the HfZnO film and annealed at $100^{\circ}C$ for 30 min. After transferring process, parallel grooves on the HfZnO film is obtained which is confirmed by atomic force microscopy and scanning electron microscopy. Uniform liquid crystal alignment is achieved which is attributed to an anisotropic characteristic of HfZnO film by parallel grooves. The liquid crystal cell exhibited a pretilt angle of $0.25^{\circ}$ which showed a homogeneous alignment property.

Research of Heavily Selective Emitter Doping for Making Solar Cell by Using the New Atmospheric Plasma Jet (새로운 대기압 플라즈마 제트를 이용한 태양전지용 고농도 선택적 도핑에 관한 연구)

  • Cho, I Hyun;Yun, Myung Soo;Son, Chan Hee;Jo, Tae Hoon;Kim, Dong Hea;Seo, Il Won;Rho, Jun Hyoung;Jeon, Bu Il;Kim, In Tae;Choi, Eun Ha;Cho, Guangsup;Kwon, Gi Chung
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.238-244
    • /
    • 2013
  • Doping process using laser is an important process in fabrication of solar cell for heat treatment. However, the process of using the furnace is difficult to form a selective emitter doping region. The case of using a selective emitter laser doping is required an expensive laser equipment and induce the wafer's structure damage due to high temperature. This study, we fabricated a new costly plasma source. Through this, we research the selective emitter doping. We fabricated that the atmospheric pressure plasma jet injected Ar gas is inputted a low frequency (a few tens kHz). We used shallow doping wafers existing PSG (Phosphorus Silicate Glass) on the shallow doping CZ P-type wafer. Atmospheric plasma treatment time was 15 s and 30 s, and current for making the plasma is 40 mA and 70 mA. We investigated a doping profile by using SIMS (Secondary Ion Mass Spectroscopy) and we grasp the sheet resistance of electrical character by using doping profile. As result of experiment, prolonged doping process time and highly plasma current occur a deeper doping depth, moreover improve sheet resistance. We grasped the wafer's surface damage after atmospheric pressure plasma doping by using SEM (Scanning Electron Microscopy). We check that wafer's surface is not changed after plasma doping and atmospheric pressure doping width is broaden by increase of plasma treatment time and current.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Fabrication of PLGA/Dextran Double-Layered Microspheres by Oil-in-Water Solvent Evaporation Method (O/W 용매 증발법을 이용한 PLGA와 덱스트란의 이중층 미립구 제조)

  • Ko Jong Tae;Lee Jae-Ho;Lee Chang-Rae;Shin Hyung Sik;Yuk Soon Hong;Kim Moon Suk;Khang Gilson;Rhee John M.;Lee Hai Bang
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.543-548
    • /
    • 2005
  • Double-layered spheres play an important role in controlling drug delivery for pharmaceutical application, because of the low initial burst compared with single-layered spheres and targetable delivery to specific organ. But it has drawback in loading drug and controlling size. In this study, we developed double-layered spheres using relatively simple oil-in-water (O/W) solvent evaporation method witw/without ultrasonication and investigated the size variation of the double-layered microspheres on the contents of poly(lactide- co-glycolide) (PLGA). Double - layered spheres were char-acterized by scanning elecron microscope (SEM), camscope, and confocal fluorescence laser microscope (CFLM). Double-layered spheres showed smooth surfaces and obvious difference between core and corona by SEM observation and camscope. We observed the fluorescent core in the double-walled spheres composed of FlTC-dextran and PLGA using CFLM. It was found that the core of the microsphere was dextran and the corona of the fabricate microsphere was PLGA. Also, the more PLGA concentration, the more the size of the fabricating double-layered sphere observed.

Full mouth rehabilitation with maxillary implant overdenture using prefabricated bar attachment system: a case report (기성품 바 어태치먼트 시스템인 SFI bar를 이용한 피개의치 전악수복 증례)

  • Shin, Eun-Jung;Joo, Han-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.331-337
    • /
    • 2014
  • In conventional bar- and clip-retained overdentures, all errors during impression making and cast fabrication result in non-passive fit of bars. SFI bar is prefabricated and assembled in the patient's mouth without the use of soldering, laser welding or conventional bonding techniques, thus reducing stress transmission to, bone loss around the implants and leading to fewer errors and lower costs. A clinical case will be presented below to demonstrate the use of the SFI Bar (Stress Free on Implant Bar) to restore an severe atrophy edentulous maxilla. In this case, no lateral stress could be applied to the implants due to the telescopic design of the bar joints. However, periodic recall check is necessary and long-term clinical results are required.