• 제목/요약/키워드: Laser Discharge

검색결과 244건 처리시간 0.023초

표면예비전리 방식을 사용한 KrF 엑사이머 레이저의 개발 (Development of KrF Excimer Laser with surface discharge preionization)

  • 박홍진;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.462-464
    • /
    • 1990
  • We report the development of a surface discharge preionized KrF discharge Laser with a new type of high-brightness Corona preionizer using a segmented columnar $BaTiO_3$ dielectric. This Laser characteristic was higher value than that obtained with the conventional corona preionizer using a glass, $Al_2O_3ceramic$, Kapton film, or a Teflon insulator.

  • PDF

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF

레이저를 이용한 방전 플라즈마중의 전계측정 기술 동향 (Technical tendency of electric field measurements in glow discharge plasmas using laser spectroscopy)

  • 최영욱;;촌강극기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1663-1665
    • /
    • 1997
  • Direct measurements of electric fields in a glow discharge are difficult because the measurement method should be sensitive to the electric field and non-intrusive. Laser spectroscopy is very suitable in that it is non-intrusive and allow in-situ measurements to be made. In this report, the measurement techniques of electric fields in glow discharge using laser spectroscopy were described.

  • PDF

고출력 Fast-Axial-Flow $CO_2$ Laser 제작 Development of High Power Fast-Axial Flow $CO_2$ Laser

  • 신동주
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.39-42
    • /
    • 1989
  • The limitations of high-power electrical lasers due to heating of the gas and the instability of the glow discharge can be alleviated by the flow of the lasing medium. In order to achieve high power and efficient laser, we are developing a fast-axial flow CO2 laser. We describe here the classification of gas-discharge CO2 lasers according to the cooling methods of the lasing medium and the design features of the fast-axial flow CO2 laser.

  • PDF

반도체 Laser 요법(療法)과 향기요법(香氣療法)을 병행(竝行)한 비연(鼻淵) 치료(治療)의 임상연구(臨床硏究) (The Clinical Study of the Parallel Treatment with Laser Therapy and Combined Essential Oil Inhalation on turbid nasal discharge(鼻淵))

  • 장규태;김장현;김기봉
    • 대한한방소아과학회지
    • /
    • 제18권1호
    • /
    • pp.49-61
    • /
    • 2004
  • Objective: The objective of this study was to assess the ability of Gagamhyunggaeyungyotang(jiajianjinggailianqiao-tang) and the enhancement of the parallel treatment with laser therapy and combined essential oil inhalation on children's turbid nasal discharge. Methods: This clinical study was carried out with the 35 cases(male 29, female 6) of children aged 4 to 14 years old who visited in the Department of Pediatrics, Dongguk University Bundang Oriental Hospital and were diagnosed as turbid nasal discharge through PNS(Paranasal Sinus) CT(Computer Tomography). To assess the impact of dosage of Gagamhyunggaeyungyo -tang(jiajianjinggailianqiao-tang), it was given in different doses. The effects of treatments are assessed with the condition of illness and PNS CT before and after the therapy. The enhancement of the parallel treatment with laser therapy and combined essential oil Inhalation was also observed same as well. Results: The Use of Gagamhyunggaeyungyo-tang(jiajianjinggailianqiao-tang) has remedied rhinorrhea, nasal congestion, sputum, sore throat, cough, postnasal discharge, headache, attention deficit and anorexia above 50%. The relationship between the dosage and the effectiveness was relative high with 28 children among 35 children. The effectiveness of the parallel treatment was above 50% higher than the herb medication only. Conclusion: The efficacy of Gagamhyunggaeyungyo-tang(Jiajianjinggailianqiao-tang) on children's turbid nasal discharge was raised when the laser therapy and the combined essential oil inhalation was paralleled.

  • PDF

방전여기 KrF 레이저 장치의 방전특성 해석 (The Analysis of Discharge Characteristics for Discharge Excited KrF Laser System)

  • 정재근;최부연;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.393-396
    • /
    • 1988
  • In discharge excited excimer laser, it is hard to say that the analysis of laser operation was well explained until now. But this can be improved by analysis the nonlinear discharge characteristics in the cavity. The nonlinear characteristics can be analysed by solving the nonlinear resistance which depends on electron mobility and number density. We can calculate the electron mobility and number density each other using Boltzmann equation and Kinetics equation. So we calculated the nonlinear resistance and analysed nonlinear discharge characteristics.

  • PDF

고전압 방전 플라즈마에 의한 질화탄소 박막 층착 시 레이저 애블레이션 효과 (Effect of a Laser Ablation for Carbon Nitride Film Deposition)

  • 김종일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.240-243
    • /
    • 2002
  • Carbon nitride films have been deposited on Si(100) substrate by a high voltage discharge plasma combined with laser ablation in a nitrogen atmosphere. The films were grown both with and without the Presence of an assisting focused Nd:YAG laser ablation. The laser ablation of the graphite target leads to vapor Plume plasma expending into the ambient nitrogen arc discharge area. X-ray photoelectron spectroscopy and Auger electron spectroscopy were used to identify the binding structure and the content of the nitrogen species in the deposited films. The surface morphology of the films was studied using a scanning electron microscopy Data of infrared spectroscopy and x-ray photoelectron spectroscopy indicate the existence of carbon-nitrogen bonds in the films. The x-ray diffraction measurements have also been taken to characterize the crystal properties of the obtain films.

  • PDF

Fabrication of Graphene Supercapacitors for Flexible Energy Storage

  • Habashi, M. Namdar;Asl, Shahab Khameneh
    • 한국재료학회지
    • /
    • 제27권5호
    • /
    • pp.248-254
    • /
    • 2017
  • In the present work, graphene powder was synthesized by laser scribing method. The resultant flexible light-scribed graphene is very appropriate for use in micro-supercapacitors. The effect of the laser scribing process in reducing graphene oxide (GO) was investigated. GO was synthesized using a chemical mixture of GO solution; then, it was coated onto a LightScribe DVD disk and laser scribed to reduce GO and create laser-scribed graphene (LSG). The CV curves of pristine rGO at various scan rates showed that the ultimate product possesses the ability to store energy at the supercapacitor level. Charge-discharge curves of pristine rGO at two different current densities indicated that the specific capacitance ($C_m$) increases due to the reduction of the discharge current density. Finally, the long-term charge-discharge stability of the LSG was plotted and indicates that the specific capacitance decreases very slightly from its primary capacitance of ${\sim}10F\;cm^{-3}$ and that the cyclic stability is favorable over 1000 cycles.

방전 플라즈마 빛의 검출량과 CO2레이저 출력의 상관관계 (The relativity of the emitted light of discharge plasma and C02 laser output)

  • 김태균;이임근;최진영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1954-1956
    • /
    • 2004
  • Nowadays, $CO_2$ lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. Especially, $CO_2$ lasers are in the spotlight at surface handling and heat processing. It is important to control the laser output power and beam Quality in those fields. And those are studied the important parameters deciding the fluctuation of laser beam are smoothing capacitor, frequency and the characteristics of laser resonator. But the study of plasma parameters of $CO_2$ lasers are little. So we detect the $CO_2$ laser from emitted $CO_2$ laser discharge plasma using a non-contact photo tansistor sensor and Low pass filter. In this study, The relativity of the emitted light of discharge plasma and CO2 laser output.

  • PDF

일체주조법, 레이저용접법, 납착법, 방전가공법에 의해 제작된 임플란트 보철물의 적합도에 관한 연구 (FIT OF IMPLANT FRAMEWORKS FABRICATED BY ONE-PIECE CASTING, LASER WELDING, SOLDERING, AND ELECTRIC DISCHARGE MACHINING)

  • 설영훈;정창모;전영찬;강성원
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.156-171
    • /
    • 2002
  • The purpose of this study was to measure and compare the strains produced by screw-tightening implant frameworks fabricated by aye different fabrication methods; (1) one-piece cast using plastic sleeve, (2) one-piece cast using gold cylinder, (3) laser welding, (4) soldering, and (5) electrical discharge machining, and also to measure and compare the strains produced when the order of screw tightening was changed A research model incorporating eighteen strain gages was made to measure the fit of implant frameworks in three dimensions. Three implants aligned in an arc were fixed on the top ends of the L-shape aluminum bars of the research model, and standard abutments were joined to the implants with abutment screws. Five types of implant framework were placed on the abutments and screwed by a torque wrench using 10 Ncm. Under the conditions of this study, the following conclusions were drawn: 1. The electrical discharge machining group showed the smallest magnitude of strain, followed by the soldering group, the laser welding group, the one-piece cast group using gold cylinder, and the one-piece cast group using plastic sleeve. However, among the magnitude of strain for the remaining groups except the electrical discharge machining group, there were not significant differences. 2. When the order of screw tightening was changed, there were not significant differences in the magnitude of strain. 3. In comparison with the electrical discharge machining group, the laser welding group and the one-piece cast groups showed greater horizontal distortion and the soldering group showed greater horizontal and vertical distortion.