• Title/Summary/Keyword: Laser Absorption Spectroscopy

Search Result 118, Processing Time 0.028 seconds

Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy (주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정)

  • 전계진;윤길원;김건식;전성만;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 1999
  • A frequency domain spectroscopic system was constructed to investigate the optical properties of multiple scattering media. The alternating current (AC) and phase lag components of backscattered light were measured by using the heterodyne detection method. Absorption and transport scattering coefficients were computed from the values based on diffusion theory. Predictions showed excellent matches in comparison with actual values of absorption and scattering. Predictable ranges of the optical coefficients were analyzed in terms of the distance between light source and detector, and modulation frequencies. A proposed compact experimental set-up using laser diodes can be utilized to estimate non-invasively the optical properties of multiple scattering media such as biological tissues.

  • PDF

Metal-insulator Transition in $(Sr_{0.75},\;La_{0.25})TiO_3$ Ultra-thin Films

  • Choi, Jae-Du;Choi, Eui-Young;Lee, Yun-Sang;Lee, Jai-Chan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.19.2-19.2
    • /
    • 2011
  • The $(Sr_{0.75},\;La_{0.25})TiO_3$ (SLTO) ultra-thin films with various thicknesses have been grown on Ti-O terminated $SrTiO_3$(100) substrate using Laser-Molecular Beam Epitaxy (Laser MBE). By monitoring the in-situ specular spot intensity oscillation of reflection high energy electron diffraction (RHEED), we controlled the layer-by-layer film growth. The film structure and topography were verified by atomic force microscopy (AFM) and high resolution thin film x-ray diffraction by the synchrotron x-ray radiation. We have also investigated the electronic band structure using x-ray absorption spectroscopy (XAS). The ultra thin SLTO film exhibits thickness driven metal-insulator transition around 8 unit cell thickness when the film thickness progressively reduced to 2 unit cell. The SLTO thin films with an insulating character showed band splitting in Ti $L_3-L_2$ edge XAS spectrum which is attributed to Ti 3d band splitting. This narrow d band splitting could drive the metal-insulator transition along with Anderson Localization. In optical conductivity, we have found the spectral weight transfer from coherent part to incoherent part when the film thickness was reduced. This result indicates the possibility of enhanced electron correlation in ultra thin films.

  • PDF

Monte Carlo Simulation on Light Distribution in Turbid Material (혼탁매질에서 광분포에 관한 Monte Carlo 시뮬레이션)

  • Kim, Ki-Jun;Sung, Ki-Chun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.11-20
    • /
    • 1998
  • The propagation of light radiation in a turbid medium is an important problem that confronts dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. Scattered light is measured as a function of the position(distance r, depth z) between the axis of the incident beam and the detection spot. Turbid sample yields a very forward-directed scattering pattern at short range of position from source to detector, whereas the thicker samples greatly attenuated the on-axis intensity at long range of position. The portions of scattered light reflected from or transmitted throughphantom depend upon internal reflectance and absorption properties of the phantom. Monte Carlo simulation method for modelling light transport in tissue is applied. It uses the photon is moved a distance where it may be scattered, absorbed, propagated, internally reflected, or transmitted out of tissue. The photon is repeatedly moved until it either escape from or is absorbed by the phantom. In order to obtain an optimum therapeutic ratio in phantom material, optimum control the light energy fluence rate is essential. This study is to discuss the physical mechanisms determining the actual light dose in phantom. Permitting a qualitative understanding of the measurements. It may also aid in designing the best model for laser medicine and application of medical engineering.

Study on Optimal Coefficients of Line Broadening Function for Performance Enhancements of CT-TDLAS (CT-레이저흡수분광법(TDLAS) 성능향상을 위한 레이저 선폭확장 함수 최적 계수 선정에 관한 연구)

  • CHOI, DOOWON;CHO, GYONGRAE;DEGUCHI, YOSHIHIRO;BAEK, TAESIL;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.773-782
    • /
    • 2016
  • The performance of the CT-TDLAS (computed tomography-tunable diode laser absorption spectroscopy) is strongly dependent upon the line broadening functions. The line of the laser beam used in the TDLAS is scattered by the natural broadening, the collisional broadening and the doppler broadening. The influence of the natural broadening to the experimental spectra obtained in the TDLAS is negligible. The influences of the collisional broadening and the doppler broadening to the experimental spectra are relatively large, in high pressure gas flows and in high temperature low pressure gas flows, respectively. In this study, optimal coefficients are proposed for the doppler broadening function by using the experimental data obtained in a flat burner test. The optimal coefficients were ${\gamma}_j=0.16$ and n=0.37. Using these coefficients, the temperature and concentration distributions at the engine exhaust gas pipe have been calculated showing their validities.

Time-resolved Anisotropy Study on the Excited-State Intramolecular Proton Transfer of 1-Hydroxyanthraquinone

  • Choi, Jun-Rye;Jeoung, Sae-Chae;Cho, Dae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.11
    • /
    • pp.1675-1679
    • /
    • 2003
  • The photodynamics of excited-state intramolecular proton transfer reaction of 1-hydroxyanthraquinone (1-HAQ) and 1-deuterioanthraquinone was investigated in toluene with time-resolved emission and femtosecond transient transmittance techniques at room temperature. The temporal profiles of transient transmittance of 1-HAQ could be well described with multi-decaying time constants. The ultrafast time constant within ca. 260 fs reflects the dynamics of proton transfer. The decay component of 2 ps is assigned to an additional proton translocation process induced by the intramolecular vibrational relaxation, whereas the decay component of 18 ps is assigned to the vibrational cooling process, while the long component (200 ps) can be explained in terms of the relaxation from excited-state keto-tautomer to its ground state. Time-resolved anisotropy decay dynamics and isotope effects on the photodynamics reveals that the ESIPT from enol-tautomer to keto-one of 1-HAQ is barrierless reaction and coupled to a vibrational relaxation process.

Effect of BSO addition on Cu-O bond of GdBa2Cu3O7-x films with varying thickness probed by extended x-ray absorption fine structure

  • Jeon, H.K.;Lee, J.K.;Yang, D.S.;Kang, W.N.;Kang, B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.4
    • /
    • pp.1-4
    • /
    • 2016
  • We investigated the relation between the Cu-O bond length and the superconducting properties of $BaSnO_3$ (BSO)-added $GdBa_2Cu_3O_{7-x}$ (GdBCO) thin films by using extended x-ray absorption fine structure (EXAFS) spectroscopy. 4 wt.% $BaSnO_3$ (BSO) added $GdBa_2Cu_3O_{7-x}$ (GdBCO) thin films with varying thickness from $0.2{\mu}m$ to $1.0{\mu}m$ were fabricated by using pulsed laser deposition (PLD) method. The transition temperature ($T_c$) and the residual resistance ratio (RRR) of the GdBCO films increased with increasing thickness up to $0.8{\mu}m$, where the crystalline BSO has the highest peak intensity, and then decreased. This uncommon behaviors of $T_c$ and RRR are likely to be created by the addition of BSO, which may change the ordering of GdBCO atomic bonds. Analysis from the Cu K-edge EXAFS spectroscopy showed an interesting thickness dependence of ordering behavior of BSO-added GdBCO films. It is noticeable that the ordering of Cu-O bond and the transition temperature are found to show opposite behaviors in the thickness dependence. Based on these results, the growth of BSO seemingly have evident effect on the alteration of the local structure of GdBCO film.

Time Resolved Electron Spin Resonance Spectroscopy of Anthrasemiquinone Radical Produced by Pulse Laser Photolysis. A Study on Chemically Induced Dynamic Electron Polarization (광화학 반응에서 생성된 Anthrasemiquinone Radical의 시간분해 ESR ; CIDEP에 관한 연구)

  • Hong Daeil;Kuwata Keiji
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.404-412
    • /
    • 1990
  • The time resolved electron spin resonance spectroscopy are used to two measurement methods of chemically induced dynamic electron polarization (CIDEP) and absorption ESR. The spectra of the semiquinone radical anion were successively detected in the laser flash photolysis of anthraquinone in the mixtures of 2-propanol and triethylamine. The semiquinone radical anion was fairly stable and its cw ESR could be observed. The rate constant (T1$^{-1}$) of the spin-depolarization of polarized semiquinone radical anion was 2.6 ${\times}\;1-^5$ sec$^{-1}$ and the decay of the radical anion was the first order with the rate constant (K$_1}$) of 300.0 sec$^{-1}$. The intensity of CIDEP spectra increased with the increasing the microwave power, but the Torrey wiggles appeared following with decay curves.

  • PDF

Development and Properties of Carbon monoxide Detector for Ambient Air monitoring (대기오염 측정용 일신화 탄소 검출기의 제작 및 특성)

  • Cho, Kyung-Haeng;Lee, Sang-Wha;Lee, Joung-Hae;Choi, Kyong-Sik
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.222-228
    • /
    • 2000
  • A detector for monitoring carbon monoxide (CO) in ambient air by nondispersive infrared (NDIR) spectroscopy has been developed and investigated its sensitivity and stability. The essential parts of the absorption cell are three spherical concave mirrors so as to improve the sensitivity by increasing the light path length in the cell. The radius and center of curvature of mirrors and position in the cell was calculated by computer simulation in order that the light path length may be 16m into the 50cm cell. The number of traversals and optical path properties were confirmed by laser beam alignment in transparent absorption cell. The photoconductive type lead selenide (PbSe) was used as CO sensing material, which was cooled to increase the responsibility by thermoelectric cooling method. The detection limit and span drift of the developed CO detector was 0.24ppm and 0.03ppm(v/v) respectively.

  • PDF

A study on measurement of oxygen in a reheating furnace using TDLAS (가열로에서 TDLAS를 이용한 각대산소농도측정에 관한 연구)

  • Kim, Young-Il;Kim, Ki-Hong;Lee, In-Bum
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.160-167
    • /
    • 2006
  • In this project, we studied more accurate and reliable sensing method for oxygen in reheating furnace, made the empirical model for NOx concentration based on oxygen and evaluate the stability of the Tuneable Diode Laser (Absorption) Spectroscopy(TDL(A)S). The tested oxygen monitoring system is installed at work-field reheating furnace on hot roll at POSCO and compared with the Zr sensor system which shows too sensitive because it measures oxygen concentration on a spot unlike TDLS sensor which is successfully applied at 13m-width reheating furnace to measures the line average along the Optical Path Line(OPL).

  • PDF

Analysis of Hematoporphyrin Derivative by Design and Manufacture of High Resolution Charge Coupled Device in Spectrometry (분광기에 고 분해능 Charge Coupled Device의 설계 및 제작에 의한 Hematoporphyrin Derivative의 분석)

  • Kim, Ki-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.77-83
    • /
    • 2005
  • The influence of fluorescence, scattering, and absorbance in turbid material by light scattering was interpreted by the scattered fluorescence intensity and wavelength. The effect of optical property in scattering media was investigated. It is very important to study the charge coupled device(CCD) in spectrometry because we can use the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy. CCD is very essential to study the molecular structure and medical engineering combined laser spectroscopy in the modem physical and chemistry. Accordingly, this study has designed and manufactured the electromagnetic spectrometry with CCD, and has analyzed the hematoporphyrin derivative.