• 제목/요약/키워드: Large-Complex System

검색결과 986건 처리시간 0.031초

전자기 과도 현상 해석을 위한 등가 시스템 (Equivalent System for Electromagnetic Transients Study)

  • 박종근;홍준희;박동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.843-847
    • /
    • 1988
  • In electromagnetic transient analysis studies, complex transmission system should be modelled in detail. But in large system, modelling of complete system is a big burden in many sides such as computation time, modelling efforts. It is needed to model only a concerned part of the system in detail. The remaining parts of the system have to be reduced to equivalents. This study suggests a method of generating a simple network equivalents which has equivalent frequency charastics in wide frequency range.

  • PDF

차세대 고속전철시스템 개발을 위한 시스템 엔지니어링 체계구축 (Development and Application of Computer Aided Systems Engineering Processes for Next Generation High Speed Railway Train)

  • 유일상;박영원
    • 한국산업경영시스템학회:학술대회논문집
    • /
    • 한국산업경영시스템학회 2002년도 춘계학술대회
    • /
    • pp.51-56
    • /
    • 2002
  • A Korea next-generation high-speed rail system represents a typical example of large- scale multi-disciplinary systems, consisting of subsystems such as train, electrical hardware, electronics, control, Information, communication, civil technology etc. The system design and acquisition data of the large-scale system must be the subject under strict configuration control and management. The system therefore, must be developed using systems engineering that is a efficient and effective methodology to design such a complex system and manage its development. This paper presents the results from a computer-aided systems engineering application to the Korea next generation high-speed railway project. Especially, the focus of the study was on requirement management and PBS management.

  • PDF

345kv 미금 변전소 외부 계통의 등가축약 기법을 이용한 EMTP 모델링에 관한 연구 (EMTP simulation of 345kv Substation in large network using newly developed Thevenin equivalent network)

  • 정기석;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.244-246
    • /
    • 2008
  • EMTP-RV is the very powerful program to analyze the dynamic operation of the power system. To use this package in the large complex power system, it is very important to simplify the power system to simple equivalent network. In our study the 100 MVA STATCOM is placed at 345kV "MIGUM" which is the one of the 345kV substations of the Korean Electric Power System that is consist of more than 1000 bus. MIGUM substation is connected with 7 separated transmission lines to main Korean Electric power system. We developed a new method to simplify the network except the substation that we want to analysis. The power system outside the 345kV substation is modeled into the equivalent network. The loop network outside the substation can be modeled to simplified Thevenin equivalent network. The proposed method is applied to IEEE-14 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

상태변수들의 관계지수를 이용한 전력시스템 축약기법 연구 (A study on aggregation method using relation index of state variables in the power system)

  • 이병하;오민혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.339-341
    • /
    • 2006
  • Increasing interconnection of power plants in modern large electric power system has made power system dynamic studies much more complex. For effective analysis of the power system, model reduction and aggregation is required. In this paper, a new relation index is presented to identify the coherent generators in the large scale power system. In order to demonstrate the effects of this relation index, it is applied to a small scale power system of IEEE 39-bus test system and the simulation results are presented.

  • PDF

The Real -Time Dispersion Modeling System

  • Koo, Youn-Seo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E4호
    • /
    • pp.215-221
    • /
    • 2002
  • The real-time modeling system, named AirWatch System, has been developed to evaluate the environmental impact from a large source. It consists of stack TMS (TeleMetering System) that measures the emission data from the source, AWS (Automatic Weather Station) that monitors the weather data and computer system with the dispersion modeling software. The modeling theories used in the system are Gaussian plume and puff models. The Gaussian plume model is used for the dispersion in the simple terrain with a point meteorological data while the puff model is for the dispersion in complex terrain with three dimensional wind fields. The AirWatch System predicts the impact of the emitted pollutants from the large source on the near-by environment on the real -time base and the alarm is issued to control the emission rate if the calculated concentrations exceed the modeling significance level.

Dynamic Analysis of Harmonically Excited Non-Linear Structure System Using Harmonic Balance Method

  • 문병영;강범수;김병수
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1507-1516
    • /
    • 2001
  • An analytical method is presented for evaluation of the steady state periodic behavior of nonlinear structural systems. This method is based on the substructure synthesis formulation and a harmonic balance procedure, which is applied to the analysis of nonlinear responses. A complex nonlinear system is divided into substructures, of which equations are approximately transformed to modal coordinates including nonlinear term under the reasonable procedure. Then, the equations are synthesized into the overall system and the nonlinear solution for the system is obtained. Based on the harmonic balance method, the proposed procedure reduces the size of large degrees-of-freedom problem in the solving nonlinear equations. Feasibility and advantages of the proposed method are illustrated using the study of the nonlinear rotating machine system as a large mechanical structure system. Results obtained are reported to be an efficient approach with respect to nonlinear response prediction when compared with other conventional methods.

  • PDF

FEEDING SYSTEM OF LARGE RUMINANTS IN RURAL BANGLADESH

  • Rahman, M.M.;Islam, M.R.;Rahman, M.M.;Zaman, M.A.;Malek, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권2호
    • /
    • pp.349-355
    • /
    • 1992
  • In order to explore feeding practices of large ruminants and methods followed in the rural areas, an exploratory survey was made during the period from January 1988 to January 1989 in eight different agro-ecological areas of Bangladesh in relation to the existing seasons and farmers' categories. The study shows what feeding practices varied (p<0.01) from area to area and season to season but not with the farmers' category. Considering the overall picture of feeding practices existing in the country, it can be observed that bigger proportion of farmers practiced stall feeding and tethering ($38.4{\pm}35.1$) followed by stall fed ($34.3{\pm}35.2$) and grazing or tethering ($17.3{\pm}26.7$). The figure with wider deviations indicates that farmers in the rural areas did not follow a smooth feeding practice, the system is rather a complex, heterogenous and a mere consequence of existing land use system. The results of feeding methods of by-product concentrates indicate that it also varied (p<0.01) from area to area but however, not with seasons and farmers' category. It is observed that bigger proportion of farmers fed concentrates to their animals mixed with water ($74.1{\pm}30.3$) followed by mixed with roughage and water ($10.3{\pm}13.3$) or fed alone ($5.6{\pm}14.2$). The method like feeding practice is also complex and heterogenous in the rural areas of Bangladesh. Hence, it is needed to develop a strategic feeding system and method identifying the problems associated with those.

G-Networks Based Two Layer Stochastic Modeling of Gene Regulatory Networks with Post-Translational Processes

  • Kim, Ha-Seong;Gelenbe, Erol
    • Interdisciplinary Bio Central
    • /
    • 제3권2호
    • /
    • pp.8.1-8.6
    • /
    • 2011
  • Background: Thanks to the development of the mathematical/statistical reverse engineering and the high-throughput measuring biotechnology, lots of biologically meaningful genegene interaction networks have been revealed. Steady-state analysis of these systems provides an important clue to understand and to predict the systematic behaviours of the biological system. However, modeling such a complex and large-scale system is one of the challenging difficulties in systems biology. Results: We introduce a new stochastic modeling approach that can describe gene regulatory mechanisms by dividing two (DNA and protein) layers. Simple queuing system is employed to explain the DNA layer and the protein layer is modeled using G-networks which enable us to account for the post-translational protein interactions. Our method is applied to a transcription repression system and an active protein degradation system. The steady-state results suggest that the active protein degradation system is more sensitive but the transcription repression system might be more reliable than the transcription repression system. Conclusions: Our two layer stochastic model successfully describes the long-run behaviour of gene regulatory networks which consist of various mRNA/protein processes. The analytic solution of the G-networks enables us to extend our model to a large-scale system. A more reliable modeling approach could be achieved by cooperating with a real experimental study in synthetic biology.

The Overview of a Digital Power System Simulator for Large Power System Analysis

  • Kim, Tae-Kyun;Kim, Yong-Hak;Shin, Jeong-Hoon;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.93-99
    • /
    • 2003
  • This paper deals with the development and testing of a large-scale, realtime digital power system simulator for the Korean Electric Power Corporation. The KEPS Simulation Center is located at KEPCO's research center (KEPRI) in Taejon, South Korea and has been operated since September 2001. The KEPS Simulation Center includes a wide range of off line power system simulation and analysis tools, as well as an advanced realtime digital simulator for the study of large scale AC and DC system performance. Because the application scope of the KEPS realtime simulator is broad and because the network models being considered are significantly larger and more complex than in traditional realtime simulator applications, many developments and tests have been required during the course of the project. In this paper, the authors describe some of these developments and present results from various benchmark tests that have been performed.

인덕턴스 변화에 강인한 계통연계형 인버터의 복소 벡터 전류제어기 (Complex Vector Current Control of Grid Connected Inverter Robust for Inductance Variation)

  • 이태진;조종민;신창훈;차한주
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1648-1654
    • /
    • 2016
  • This paper analyzes complex vector current control for the enhanced cross-coupling compensation in accordance with parameter variation in grid-connected inverter system, and verifies through simulation and experiment. Complex vector current control is performed in the synchronous reference frame through d-q transformation. It generates cross-coupling components with rotating nominal angular frequency. In general, cross-coupling elements are compensated by decoupling terms added to output of conventional decoupling PI controller. But, it is impossible to compensate them perfectly which transient response is especially deteriorated such as large overshoot and slow tracking, when variation of grid impedance or measurement error occurs. However, complex vector current control can improve stability and response characteristic of current control regardless of the situation as before. Decoupling controller and complex vector controller are represented through complex forms, and these controllers are analyzed by using frequency response in s-domain, respectively. It is verified that complex vector controller has more superior response characteristic than decoupling controller through MATALB, PSIM and experimental in 5kW grid-connected inverter when L filter parameter is varied from 1.1mH to increase double, 2.2mH.