• 제목/요약/키워드: Large stud shear connector

검색결과 9건 처리시간 0.023초

Numerical analysis of large stud shear connector embedded in HFRC

  • He, Yu Liang;Zhang, Chong;Wang, Li Chao;Yang, Ying;Xiang, Yi Qiang
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.595-608
    • /
    • 2021
  • To investigate the mechanical behavior of large stud shear connector embedded in hybrid fiber-reinforced concrete (HFRC), a refined 3D nonlinear finite element (FE) model incorporating the constitutive model of HFRC was developed using ANSYS. Firstly, the test results conducted by the authors (He et al. 2017) were used to validate FE model of push out tests. Secondly, a total of 27 specimens were analyzed with various parameters including fiber volume fractions of HFRC, diameter of studs and HFRC strength. Finally, an empirical equation considering the contribution of steel fiber (SF) and polypropylene fiber (PF) was recommended to estimate the ultimate capacity of large stud shear connector embedded in HFRC.

Review of stud shear resistance prediction in steel-concrete composite beams

  • Bonilla, Jorge;Bezerra, Luciano M.;Mirambell, Enrique;Massicotte, Bruno
    • Steel and Composite Structures
    • /
    • 제27권3호
    • /
    • pp.355-370
    • /
    • 2018
  • In steel-concrete composite beams, longitudinal shear forces are transferred across steel flange-concrete slab interface by means of shear connectors. The connector behavior is highly non-linear and involves several complex mechanisms. The design resistance and stiffness of composite beams depends on the shear connection behavior and the accuracy in the connector resistance prediction is essential. However determining the stud shear resistance is not an easy process: analytical methods do not give an adequate response to this problem and it is therefore necessary to use experimental methods. This paper present a summary of the main procedures to predict the resistance of the stud shear connectors embedded in solid slab, and stud shear connectors in composite slab using profiled steel sheeting with rib perpendicular to steel beam. A large number of experimental studies on the behavior of stud shear connectors and reported in the literature are also summarized. A comparison of the stud shear resistance prediction using six reference codes (AISC, AASHTO, Eurocode-4, GB50017, JSCE and AS2327.1) and other procedures reported in the literature against experimental results is presented. From this exercise, it is concluded that there are still inaccuracies in the prediction of stud shear resistance in all analysed procedures and that improvements are needed.

대직경 스터드 전단연결재의 피로거동 (Fatigue Behavior of Large Stud Shear Connectors)

  • 심창수;이필구;김현호;윤태양
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.621-628
    • /
    • 2003
  • 스터드 전단연결재는 강합성 구조에서 가장 많이 사용되는 전단연결재인데 현재는 주로 22mm 직경까지를 사용하고있다. 시방규정에서 제시하고 있는 적용범위의 확대를 위해서 25mm 이상의 대직경 스터드 전단연결재에 대한 연구가 필요하다. 현재의 전단연결재 설계 범위를 넘어서는 대직경 스터드 전단연결에 대한 push-out 실험을 통해서 피로거동을 검토하고 기존 설계식과의 비교를 수행하였다. 25, 27, 30mm 직경의 스터드에 대한 전단실험을 통해서 탄성영역에서의 전단강성을 평가하여 정적 실험결과와 비교하였다. 피로 하중을 받는 대직경 스터드의 피로거동을 잔류 슬립과 하중-슬립 곡선으로 설명하였다. 용접부 피로균열의 발생시점을 변위진폭으로부터 유추하는 것이 타당한 것으로 밝혀졌다. 기존 시방규정의 S-N 곡선과의 비교를 통해서 대직경 스터드 전단연결재의 피로 수명은 현재의 설계 규정을 준용해도 무방한 것으로 나타났다.

Determination of shear stiffness for headed-stud shear connectors using energy balance approach

  • Ye, Huawen;Huang, Ruosen;Tang, Shiqing;Zhou, Yu;Liu, Jilin
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.477-487
    • /
    • 2022
  • The shear stiffness of headed-stud shear connectors has no unified definition due to the nonlinear characteristics of its load-slip relationship. A unified framework was firstly adopted to develop a general expression of shear load-slip equation for headed-stud shear connectors varying in a large parameter range based on both force and energy balance. The pre- and post-yield shear stiffness were then determined through bilinear idealization of proposed shear load-slip equation. An updated and carefully selected push-out test database of 157 stud shear connectors, conducting on studs 13~30mm in diameter and on concretes 30~180 MPa in cubic compressive strength, was used for model regression and sensitivity analysis of shear stiffness. An empirical calculation model was also established for the stud shear stiffness. Compared with the previous models through statistical analysis, the proposed model demonstrates a better performance to predict the shear load-slip response and stiffness of the stud shear connectors.

Experimental study on the hybrid shear connection using headed studs and steel plates

  • Baek, Jang-Woon;Yang, Hyeon-Keun;Park, Hong-Gun;Eom, Tae-Sung;Hwang, Hyeon-Jong
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.649-662
    • /
    • 2020
  • Although several types of rigid shear connectors have been developed particularly to increase load-carrying capacity, application is limited due to the complicated details of such connection. In this study, push-out tests were performed for specimens with hybrid shear connectors using headed studs and shear plates to identify the effects of each parameter on the structural performance of such shear connection. The test parameters included steel ratios of headed stud to shear plate, connection length, and embedded depth of shear plates. The peak strength and residual strength were estimated using various shear transfer mechanisms such as stud shear, concrete bearing, and shear friction. The hybrid shear connectors using shear plates and headed studs showed large load-carrying capacity and deformation capacity. The peak strength was predicted by the concrete bearing strength of the shear plates. The residual strength was sufficiently predicted by the stud shear strength of headed studs or by shear friction strength of dowel reinforcing bars. Further, the finite element analysis was performed to verify the shear transfer mechanism of the connection with hybrid shear connector.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

대직경 스터드 전단연결재의 정적거동 (Static Behavior of Large Stud Shear Connectors)

  • 이필구;심창수;윤태양
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.611-620
    • /
    • 2003
  • 강합성교량에서 19mm 또는 22mm 직경을 갖는 전단연결재가 일반적으로 사용되고 있다. 강교 상세의 단순화와 향후 바닥판 제거의 용이성 및 프리캐스트 바닥판 전단포켓의 효율적인 배치를 위해서는 대직경 스터드 전단연결재가 필요하다. 현재의 전단연결재 설계범위를 넘어서는 대직경 스터드 전단연결재에 대한 push-out 실험을 통해서 정적거동에 관한 항목들을 검토하고 기존 설계식과의 비교를 수행하였다. 25, 27, 30mm 직경의 스터드에 대한 전단실험을 통해서 탄성영역에서의 전단강성을 평가하고 세 개의 직선으로 구성된 하중-상대변위 곡선을 제안하였다. 파괴시의 극한상대변위를 평가하고 극한강도를 유로코드-4의 설계식과 비교하여 설계의 안전율을 평가하였다. 또한 30mm 스터드의 경우는 용접과 콘크리트 지압능력의 개선이 필요한 것으로 나타났다.

부분합성보를 이용한 대직경 스터드의 구조거동 평가 (Evaluation of Structural Behavior of Large Studs Using Partial Composite Beams)

  • 심창수;이필구;하태열
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.425-432
    • /
    • 2004
  • 강합성교량 상부 구조의 단면 단순화 경향과 더불어 프리캐스트 교량과 같이 전단연결재를 위한 전단포켓의 등간격 배치를 필요로 하는 전단연결부의 설계를 위해서 대직경 스터드가 제안되었다. 25mm 이상의 직경을 가진 스터드 전단연결재에 대한 push-out 실험 결과를 바탕으로 합성보에서의 거동을 평가하기 위하여 40% 합성정도를 가진 부분합성보를 제작하여 정적실험을 수행하였다. 전단연결재의 직경과 배치를 변수로 설계된 부분합성보의 극한 강도 및 수평전단력의 재분배를 평가하고 전단지간내의 스터드들의 그룹파괴를 확인하였다. 전단연결부의 강도가 부분합성보의 강도를 지배하기 때문에 이로부터 전단연결재의 전단강도를 평가하였는데 push-out 실험결과에 비해서 상당히 높은 수준의 강도 증가를 보여주었다. 하중-상대변위 곡선으로부터 대직경 스터드의 합성보에서의 충분한 연성과 하중재분배 능력을 확인하였다. 대직경 스터드를 적용하여 등간격 배치를 할 경우에 정적 거동에는 문제가 없는 것으로 나타났다.

골형 합성 테크플레이트를 사용한 반슬림 합성보의 개발에 관한 실험적 연구 (An Experimental Study on the Development of Semi-Slim Composite Beam with Traperzodial Composite Deck Plate)

  • 배규웅;오상훈;허병욱;양명숙
    • 한국강구조학회 논문집
    • /
    • 제13권1호
    • /
    • pp.29-40
    • /
    • 2001
  • 상업건축물에서 사용이 증가하고 있는 철골조 건물은 일반적으로 콘크리트 바닥 슬래브와 함께 합성거동하도록 설계된다. 현제 "합성 구조"가 사용성 측면에서 경제적이고 작업성이 좋으며, 시공상의 편의성 등의 장점이 있다는 것은 일반화된 사실이지만, 자체의 춤이 깊기 때문에 철골조 아파트에 적용되기에는 어려움이 있다. 따라서 본 연구는 이러한 합성의 전체 춤을 절감할 수 있는 반슬림플로어 시스템을 개발하였다. 본 시스템은 철골보 춤내에 콘크리트 슬래브를 삽입하여 일체화함으로써 철골조 고층건물에서 층고를 최소화 할 수 있는 공법이다. 실험은 12개의 합성슬래브 실험체를 데크현상, 슬래브폭, 스터드볼트의 유무와 콘크리트 토핑두께를 변수로하여 휨성능을 평가하였다.

  • PDF